메뉴 건너뛰기




Volumn 36, Issue 6, 2016, Pages 599-602

Development of a novel quality improvement indicator based on the hemolysis index

Author keywords

H index; Hemolysis; Preanalytical error; Quality improvement indicator

Indexed keywords

HEMOGLOBIN; LACTATE DEHYDROGENASE;

EID: 84986269512     PISSN: 22343806     EISSN: 22343814     Source Type: Journal    
DOI: 10.3343/alm.2016.36.6.599     Document Type: Review
Times cited : (6)

References (12)
  • 2
    • 0018639298 scopus 로고
    • Evaluation of a nephelometric assay for haptoglobin and its clinical usefulness
    • Van Lente F, Marchand A, Galen RS. Evaluation of a nephelometric assay for haptoglobin and its clinical usefulness. Clin Chem 1979;25: 2007-10.
    • (1979) Clin Chem , vol.25 , pp. 2007-2010
    • Van Lente, F.1    Marchand, A.2    Galen, R.S.3
  • 3
    • 0018087784 scopus 로고
    • Effects of bilirubin on detection of hydrogen peroxide by use of peroxidase
    • Witte DL, Brown LF, Feld RD. Effects of bilirubin on detection of hydrogen peroxide by use of peroxidase. Clin Chem 1978;24:1778-82.
    • (1978) Clin Chem , vol.24 , pp. 1778-1782
    • Witte, D.L.1    Brown, L.F.2    Feld, R.D.3
  • 4
    • 0022898206 scopus 로고
    • Bilirubin interference with determination of uric acid, cholesterol, and triglycerides in commercial peroxidase-coupled assays, and the effect of ferrocyanide
    • Spain MA and Wu AH. Bilirubin interference with determination of uric acid, cholesterol, and triglycerides in commercial peroxidase-coupled assays, and the effect of ferrocyanide. Clin Chem 1986;32:518-21.
    • (1986) Clin Chem , vol.32 , pp. 518-521
    • Spain, M.A.1    Wu, A.H.2
  • 5
    • 7044241205 scopus 로고    scopus 로고
    • Evaluating interference caused by lipemia
    • Kroll MH. Evaluating interference caused by lipemia. Clin Chem 2004;50:1968-9.
    • (2004) Clin Chem , vol.50 , pp. 1968-1969
    • Kroll, M.H.1
  • 6
    • 7044260841 scopus 로고    scopus 로고
    • Assay-specific differences in lipemic interference in native and intralipid-supplemented samples
    • Bornhorst JA, Roberts RF, Roberts WL. Assay-specific differences in lipemic interference in native and intralipid-supplemented samples. Clin Chem 2004;50:2197-201.
    • (2004) Clin Chem , vol.50 , pp. 2197-2201
    • Bornhorst, J.A.1    Roberts, R.F.2    Roberts, W.L.3
  • 8
    • 44949158707 scopus 로고    scopus 로고
    • Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories
    • Lippi G, Blanckaert N, Bonini P, Green S, Kitchen S, Palicka V, et al. Haemolysis: An overview of the leading cause of unsuitable specimens in clinical laboratories. Clin Chem Lab Med 2008;46:764-72.
    • (2008) Clin Chem Lab Med , vol.46 , pp. 764-772
    • Lippi, G.1    Blanckaert, N.2    Bonini, P.3    Green, S.4    Kitchen, S.5    Palicka, V.6
  • 9
    • 84904443327 scopus 로고    scopus 로고
    • Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results
    • Shin DH, Kim J, Uh Y, Lee SI, Seo DM, Kim KS, et al. Development of an integrated reporting system for verifying hemolysis, icterus, and lipemia in clinical chemistry results. Ann Lab Med 2014;34:307-12.
    • (2014) Ann Lab Med , vol.34 , pp. 307-312
    • Shin, D.H.1    Kim, J.2    Uh, Y.3    Lee, S.I.4    Seo, D.M.5    Kim, K.S.6
  • 12
    • 62449153784 scopus 로고    scopus 로고
    • Laboratory medicine quality indicators: A review of the literature
    • Shahangian S and Snyder SR. Laboratory medicine quality indicators: A review of the literature. Am J Clin Pathol 2009;131:418-31.
    • (2009) Am J Clin Pathol , vol.131 , pp. 418-431
    • Shahangian, S.1    Snyder, S.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.