-
1
-
-
84952809515
-
Ion-selective electrodes for measurements in biological fluids
-
Wiley-VCH Alabama, US
-
Bakker, E., Meyerhoff, M.E., Ion-selective electrodes for measurements in biological fluids. Encyclopedia of Electrochemistry, 2007, Wiley-VCH, Alabama, US, 277–307.
-
(2007)
Encyclopedia of Electrochemistry
, pp. 277-307
-
-
Bakker, E.1
Meyerhoff, M.E.2
-
2
-
-
0035878202
-
Influence of natural, electrically neutral lipids on the potentiometric responses of cation-selective polymeric membrane electrodes
-
Bühlmann, P., Hayakawa, M., Ohshiro, T., Amemiya, S., Umezawa, Y., Influence of natural, electrically neutral lipids on the potentiometric responses of cation-selective polymeric membrane electrodes. Anal. Chem. 73 (2001), 3199–3205.
-
(2001)
Anal. Chem.
, vol.73
, pp. 3199-3205
-
-
Bühlmann, P.1
Hayakawa, M.2
Ohshiro, T.3
Amemiya, S.4
Umezawa, Y.5
-
3
-
-
0032099044
-
Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors
-
Bühlmann, P., Pretsch, E., Bakker, E., Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors. Chem. Rev. 98 (1998), 1593–1688.
-
(1998)
Chem. Rev.
, vol.98
, pp. 1593-1688
-
-
Bühlmann, P.1
Pretsch, E.2
Bakker, E.3
-
4
-
-
84986298003
-
Section III – analytes
-
Elsevier Inc St. Louis, Missouri
-
Burtis, C., Ashwood, E., Bruns, D., Section III – analytes. Tietz Textbook of Clinical Chemistry and Molecular Diagnostics, 63043, 2012, Elsevier Inc, St. Louis, Missouri, 669–707.
-
(2012)
Tietz Textbook of Clinical Chemistry and Molecular Diagnostics
, vol.63043
, pp. 669-707
-
-
Burtis, C.1
Ashwood, E.2
Bruns, D.3
-
5
-
-
0023223013
-
Clinical value of the creatinine clearance before the administration of chemotherapy with cisplatin
-
Davila, E., Gardner, L.B., Clinical value of the creatinine clearance before the administration of chemotherapy with cisplatin. Cancer 15 (1987), 161–164.
-
(1987)
Cancer
, vol.15
, pp. 161-164
-
-
Davila, E.1
Gardner, L.B.2
-
6
-
-
51849104710
-
Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement
-
Delanghe, J.R., Cobbaert, C., Galteau, M.M., Harmoinen, A., Jansen, R., Kruse, R., Laitinen, P., Thienpont, L.M., Wuyts, B., Weykamp, C., Panteghini, M., Trueness verification of actual creatinine assays in the European market demonstrates a disappointing variability that needs substantial improvement. Clin. Chem. Lab. Med. 46 (2008), 1319–1325.
-
(2008)
Clin. Chem. Lab. Med.
, vol.46
, pp. 1319-1325
-
-
Delanghe, J.R.1
Cobbaert, C.2
Galteau, M.M.3
Harmoinen, A.4
Jansen, R.5
Kruse, R.6
Laitinen, P.7
Thienpont, L.M.8
Wuyts, B.9
Weykamp, C.10
Panteghini, M.11
-
7
-
-
84888244566
-
KDIGO 2012 Clinical practice guideline for the evaluation and management of chronic kidney disease
-
Eknoyan, G., Lameire, N., Eckardt, K.-U., KDIGO 2012 Clinical practice guideline for the evaluation and management of chronic kidney disease. Kidney Int.(Suppl. 3), 2013, S63–S72.
-
(2013)
Kidney Int.
, pp. S63-S72
-
-
Eknoyan, G.1
Lameire, N.2
Eckardt, K.-U.3
-
8
-
-
33645996080
-
New potentiometric sensors for creatinine
-
Elmosallamy, M.A.F., New potentiometric sensors for creatinine. Anal. Chim. Acta 564 (2006), 253–257.
-
(2006)
Anal. Chim. Acta
, vol.564
, pp. 253-257
-
-
Elmosallamy, M.A.F.1
-
9
-
-
84872129835
-
Tautomeric equilibrium of creatinine and creatininium cation in aqueous solutions explored by Raman spectroscopy and density functional theory calculations
-
Gao, J., Hu, Y., Li, S., Zhang, Y., Chen, X., Tautomeric equilibrium of creatinine and creatininium cation in aqueous solutions explored by Raman spectroscopy and density functional theory calculations. Chem. Phys. 410 (2013), 81–89.
-
(2013)
Chem. Phys.
, vol.410
, pp. 81-89
-
-
Gao, J.1
Hu, Y.2
Li, S.3
Zhang, Y.4
Chen, X.5
-
10
-
-
84957846842
-
Recognition and sensing of creatinine
-
Guinovart, T., Hernández-Alonso, D., Adriaenssens, L., Blondeau, P., Martinez-Belmonte, M., Rius, F.X., Andrade, F.J., Ballester, P., Recognition and sensing of creatinine. Angew. Chem. Int. Ed. 55 (2016), 2435–2440.
-
(2016)
Angew. Chem. Int. Ed.
, vol.55
, pp. 2435-2440
-
-
Guinovart, T.1
Hernández-Alonso, D.2
Adriaenssens, L.3
Blondeau, P.4
Martinez-Belmonte, M.5
Rius, F.X.6
Andrade, F.J.7
Ballester, P.8
-
11
-
-
29744455869
-
Novel biomedical sensors for flow injection potentiometric determination of creatinine in human serum
-
Hassan, S.S.M., Elnemma, E.M., Mohamed, A.H.K., Novel biomedical sensors for flow injection potentiometric determination of creatinine in human serum. Electroanalysis 17 (2005), 2246–2253.
-
(2005)
Electroanalysis
, vol.17
, pp. 2246-2253
-
-
Hassan, S.S.M.1
Elnemma, E.M.2
Mohamed, A.H.K.3
-
12
-
-
84986244811
-
Evaluation of the patient with kidney disease, in: The Kidney, Elsevier, Philadelphia, PA 19103-2899
-
868–888.
-
Israni, A.K., Kasiske, B.L., 2012. Evaluation of the patient with kidney disease, in: The Kidney, Elsevier, Philadelphia, PA 19103-2899, pp. 868–888.
-
(2012)
-
-
Israni, A.K.1
Kasiske, B.L.2
-
13
-
-
0026350189
-
Effects of interferents on the kinetic Jaffe reaction and an enzymatic colorimetric test for serum creatinine concentration
-
Jacobs, R.M., Lumsden, J.H., Taylor, J.A., Grift, E., Effects of interferents on the kinetic Jaffe reaction and an enzymatic colorimetric test for serum creatinine concentration. Can. J. Vet. Res. 55 (1991), 150–154.
-
(1991)
Can. J. Vet. Res.
, vol.55
, pp. 150-154
-
-
Jacobs, R.M.1
Lumsden, J.H.2
Taylor, J.A.3
Grift, E.4
-
14
-
-
37049081824
-
Selective sensing of guanidinium and tetraalkylammonium ions using lipophilic cyclodextrins
-
Kelly, P.M., Kataky, R., Parker, D., Patti, A.F., Selective sensing of guanidinium and tetraalkylammonium ions using lipophilic cyclodextrins. J. Chem. Soc. Perkin Trans. 2 (1995), 1955–1963.
-
(1995)
J. Chem. Soc. Perkin Trans.
, vol.2
, pp. 1955-1963
-
-
Kelly, P.M.1
Kataky, R.2
Parker, D.3
Patti, A.F.4
-
15
-
-
0033485340
-
Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes
-
Mi, Y., Bakker, E., Determination of complex formation constants of lipophilic neutral ionophores in solvent polymeric membranes with segmented sandwich membranes. Anal. Chem. 71 (1999), 5279–5287.
-
(1999)
Anal. Chem.
, vol.71
, pp. 5279-5287
-
-
Mi, Y.1
Bakker, E.2
-
16
-
-
84895561411
-
A paper-based potentiometric cell for decentralized monitoring of Li levels in whole blood
-
Novell, M., Guinovart, T., Blondeau, P., Rius, F.X., Andrade, F.J., A paper-based potentiometric cell for decentralized monitoring of Li levels in whole blood. Lab. Chip 14 (2014), 1308–1314.
-
(2014)
Lab. Chip
, vol.14
, pp. 1308-1314
-
-
Novell, M.1
Guinovart, T.2
Blondeau, P.3
Rius, F.X.4
Andrade, F.J.5
-
17
-
-
0022885504
-
Ion-selective membrane electrodes for clinical use
-
Oesch, U., Ammann, D., Simon, W., Ion-selective membrane electrodes for clinical use. Clin. Chem. 32 (1986), 1448–1459.
-
(1986)
Clin. Chem.
, vol.32
, pp. 1448-1459
-
-
Oesch, U.1
Ammann, D.2
Simon, W.3
-
18
-
-
84986293865
-
Stabilized alkaline picrate reagent for Jaffe creatinine determination
-
US1989/4818703
-
Pizzolante, J.M., 1989. Stabilized alkaline picrate reagent for Jaffe creatinine determination, US1989/4818703.
-
(1989)
-
-
Pizzolante, J.M.1
-
19
-
-
2542450032
-
Creatinine normalization in biological monitoring revisited
-
Viau, C., Lafontaine, M., Payan, J.P., Creatinine normalization in biological monitoring revisited. Int. Arch. Occup. Environ. Health 77 (2004), 177–185.
-
(2004)
Int. Arch. Occup. Environ. Health
, vol.77
, pp. 177-185
-
-
Viau, C.1
Lafontaine, M.2
Payan, J.P.3
-
20
-
-
77953359191
-
The applicability of urinary creatinine as a method of specimen normalization in the cystic fibrosis population
-
Wagner, B.D., Accurso, F.J., Laguna, T.A., The applicability of urinary creatinine as a method of specimen normalization in the cystic fibrosis population. J. Cyst. Fibros. 9 (2010), 212–216.
-
(2010)
J. Cyst. Fibros.
, vol.9
, pp. 212-216
-
-
Wagner, B.D.1
Accurso, F.J.2
Laguna, T.A.3
|