메뉴 건너뛰기




Volumn 120, Issue 9, 2016, Pages 1082-1096

Cardiorespiratory fitness estimation using wearable sensors: Laboratory and free-living analysis of context-specific submaximal heart rates

Author keywords

Cardiorespiratory fitness; Context recognition; Heart rate; Physical activity; Wearable sensors

Indexed keywords

ADULT; AMBULATORY MONITORING; CARDIORESPIRATORY FITNESS; DAILY LIFE ACTIVITY; ENERGY METABOLISM; EXERCISE TEST; FEMALE; HEART RATE; HUMAN; MALE; OXYGEN CONSUMPTION; PHYSIOLOGY; PROCEDURES; WALKING;

EID: 84984706583     PISSN: 87507587     EISSN: 15221601     Source Type: Journal    
DOI: 10.1152/japplphysiol.00519.2015     Document Type: Article
Times cited : (23)

References (32)
  • 1
    • 84876222948 scopus 로고    scopus 로고
    • Energy expenditure estimation using wearable sensors: A new methodology for activity-specific models
    • WH '12. New York, NY: ACM
    • Altini M, Penders J, Amft O. Energy expenditure estimation using wearable sensors: a new methodology for activity-specific models. In: Proceedings of the Conference on Wireless Health, WH '12. New York, NY: ACM, vol. 1, p. 8.
    • Proceedings of the Conference on Wireless Health , vol.1 , pp. 8
    • Altini, M.1    Penders, J.2    Amft, O.3
  • 3
    • 84991207759 scopus 로고    scopus 로고
    • Estimating energy expenditure using body-worn accelerometers: A comparison of methods, sensors number and positioning
    • Altini M, Penders J, Vullers R, Amft O. Estimating energy expenditure using body-worn accelerometers: a comparison of methods, sensors number and positioning. IEEE J Biomed Health Inform 99: 1, 2014.
    • (2014) IEEE J Biomed Health Inform , vol.99 , pp. 1
    • Altini, M.1    Penders, J.2    Vullers, R.3    Amft, O.4
  • 5
    • 84873761491 scopus 로고
    • A nomogram for calculation of aerobic capacity (physical fitness) from pulse rate during submaximal work
    • Astrand PO, Ryhming I. A nomogram for calculation of aerobic capacity (physical fitness) from pulse rate during submaximal work. J Appl Physiol 7: 218-221, 1954.
    • (1954) J Appl Physiol , vol.7 , pp. 218-221
    • Astrand, P.O.1    Ryhming, I.2
  • 6
    • 69749105447 scopus 로고    scopus 로고
    • Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometer
    • Bonomi AG, Plasqui G, Goris AH, Westerterp KR. Improving assessment of daily energy expenditure by identifying types of physical activity with a single accelerometer. J Appl Physiol 107: 655-661, 2009.
    • (2009) J Appl Physiol , vol.107 , pp. 655-661
    • Bonomi, A.G.1    Plasqui, G.2    Goris, A.H.3    Westerterp, K.R.4
  • 7
    • 34547638413 scopus 로고    scopus 로고
    • Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity
    • Brage S, Ekelund U, Brage N, Hennings MA, Froberg K, Franks PW, Wareham NJ, 2007. Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity. J Appl Physiol 103: 682-692, 2007.
    • (2007) J Appl Physiol , vol.103 , pp. 682-692
    • Brage, S.1    Ekelund, U.2    Brage, N.3    Hennings, M.A.4    Froberg, K.5    Franks, P.W.6    Wareham, N.J.7
  • 8
    • 24344491553 scopus 로고    scopus 로고
    • Energetic cost and preferred speed of walking in obese vs normal weight women
    • Browning RC, Kram R. Energetic cost and preferred speed of walking in obese vs. normal weight women. Obesity Res 13: 891-899, 2005.
    • (2005) Obesity Res , vol.13 , pp. 891-899
    • Browning, R.C.1    Kram, R.2
  • 11
    • 84856915771 scopus 로고    scopus 로고
    • Cross-validation of the polar fitness test TM via the polar f11 heart rate monitor in predicting v ? O2 max
    • Esco MR. Cross-validation of the polar fitness test TM via the polar f11 heart rate monitor in predicting V ? O2 max. J Exercise Physiol 14: 31-37, 2011.
    • (2011) J Exercise Physiol , vol.14 , pp. 31-37
    • Esco, M.R.1
  • 13
    • 0017064930 scopus 로고
    • The Canadian Home Fitness Test as a predictor of aerobic capacity
    • Jetté M, Campbell J, Mongeon J, Routhier R. The Canadian Home Fitness Test as a predictor of aerobic capacity. Can Med Assoc J 114: 680-682, 1976.
    • (1976) Can Med Assoc J , vol.114 , pp. 680-682
    • Jetté, M.1    Campbell, J.2    Mongeon, J.3    Routhier, R.4
  • 14
    • 0029614886 scopus 로고
    • Effects of weight loss vs aerobic exercise training on risk factors for coronary disease in healthy, obese, middle-aged and older men: A randomized controlled trial
    • Katzel LI, Bleecker ER, Colman EG, Rogus EM, Sorkin JD, Goldberg AP. Effects of weight loss vs aerobic exercise training on risk factors for coronary disease in healthy, obese, middle-aged and older men: a randomized controlled trial. J Am Med Assoc 274: 1915-1921, 1995.
    • (1995) J Am Med Assoc , vol.274 , pp. 1915-1921
    • Katzel, L.I.1    Bleecker, E.R.2    Colman, E.G.3    Rogus, E.M.4    Sorkin, J.D.5    Goldberg, A.P.6
  • 16
    • 78651075999 scopus 로고    scopus 로고
    • Mortality trends in the general population: The importance of cardiorespiratory fitness
    • Lee DC, Artero EG, Sui E, Blair SN. Mortality trends in the general population: the importance of cardiorespiratory fitness. J Psychopharmacol 24, Suppl 4: 27-35, 2010.
    • (2010) J Psychopharmacol , vol.24 , pp. 27-35
    • Lee, D.C.1    Artero, E.G.2    Sui, E.3    Blair, S.N.4
  • 17
    • 0033764678 scopus 로고    scopus 로고
    • Controlled 5-mo aerobic training improves heart rate but not heart rate variability or baroreflex sensitivity
    • Loimaala A, Huikuri H, Oja P, Pasanen M, Vuori I. Controlled 5-mo aerobic training improves heart rate but not heart rate variability or baroreflex sensitivity. J Appl Physiol 89: 1825-1829, 2000.
    • (2000) J Appl Physiol , vol.89 , pp. 1825-1829
    • Loimaala, A.1    Huikuri, H.2    Oja, P.3    Pasanen, M.4    Vuori, I.5
  • 18
    • 0002368073 scopus 로고
    • Relationship between a two mile run for time and maximal oxygen uptake
    • Mello RP, Murphy MM, Vogel JA. Relationship between a two mile run for time and maximal oxygen uptake. J Strength Cond Res 2: 9-12, 1988.
    • (1988) J Strength Cond Res , vol.2 , pp. 9-12
    • Mello, R.P.1    Murphy, M.M.2    Vogel, J.A.3
  • 19
    • 0041627691 scopus 로고    scopus 로고
    • A feedback-controlled treadmill (treadmill-on-demand) and the spontaneous speed of walking and running in humans
    • Minetti AE, Boldrini L, Brusamolin L, Zamparo P, McKee T. A feedback-controlled treadmill (treadmill-on-demand) and the spontaneous speed of walking and running in humans. J Appl Physiol 95: 838-843, 2003.
    • (2003) J Appl Physiol , vol.95 , pp. 838-843
    • Minetti, A.E.1    Boldrini, L.2    Brusamolin, L.3    Zamparo, P.4    McKee, T.5
  • 21
    • 0033867933 scopus 로고    scopus 로고
    • Submaximal exercise testing: Clinical application and interpretation
    • Noonan V, Dean E. Submaximal exercise testing: clinical application and interpretation. Phys Ther 80: 782-807, 2000.
    • (2000) Phys Ther , vol.80 , pp. 782-807
    • Noonan, V.1    Dean, E.2
  • 22
    • 33747033914 scopus 로고    scopus 로고
    • Accelerometry and heart rate as a measure of physical fitness: Cross-validation
    • Plasqui G, Westerterp KR. Accelerometry and heart rate as a measure of physical fitness: cross-validation. Med Sci Sports Exerc 38: 1510-1514, 2006.
    • (2006) Med Sci Sports Exerc , vol.38 , pp. 1510-1514
    • Plasqui, G.1    Westerterp, K.R.2
  • 23
    • 0034983999 scopus 로고    scopus 로고
    • Estimating energy expenditure by heart-rate monitoring without individual calibration
    • Rennie KL, Hennings SJ, Mitchell J, Wareham NJ. Estimating energy expenditure by heart-rate monitoring without individual calibration. Med Sci Sports Exerc 33: 939-945, 2001.
    • (2001) Med Sci Sports Exerc , vol.33 , pp. 939-945
    • Rennie, K.L.1    Hennings, S.J.2    Mitchell, J.3    Wareham, N.J.4
  • 24
    • 77950986201 scopus 로고    scopus 로고
    • Robust beat detector for ambulatory cardiac monitoring
    • Annual International Conference of the IEEE. Minneapolis, MN: IEEE
    • Romero I, Grundlehner B, Penders J. Robust beat detector for ambulatory cardiac monitoring. In: Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE. Minneapolis, MN: IEEE, 2009, p. 950-953.
    • (2009) Engineering in Medicine and Biology Society, 2009. EMBC 2009 , pp. 950-953
    • Romero, I.1    Grundlehner, B.2    Penders, J.3
  • 25
    • 35348971908 scopus 로고    scopus 로고
    • An artificial neural network model of energy expenditure using nonintegrated acceleration signals
    • Rothney MP, Neumann M, Béziat A, Chen KY. An artificial neural network model of energy expenditure using nonintegrated acceleration signals. J Appl Physiol 103: 1419-1427, 2007.
    • (2007) J Appl Physiol , vol.103 , pp. 1419-1427
    • Rothney, M.P.1    Neumann, M.2    Béziat, A.3    Chen, K.Y.4
  • 26
    • 0037629912 scopus 로고    scopus 로고
    • Predicting maximum oxygen uptake from a modified 3-minute step test
    • Santo AS, Golding LA. Predicting maximum oxygen uptake from a modified 3-minute step test. Res Q Exer Sport 741: 110-115, 2003.
    • (2003) Res Q Exer Sport , vol.741 , pp. 110-115
    • Santo, A.S.1    Golding, L.A.2
  • 29
    • 84867044701 scopus 로고    scopus 로고
    • Comparing vo2max determined by using the relation between heart rate and accelerometry with submaximal estimated vo2max
    • Tonis T, Gorter K, Vollenbroek-Hutten M, Hermens H. Comparing vo2max determined by using the relation between heart rate and accelerometry with submaximal estimated vo2max. J Sports Med Phys Fitness 52: 337-343, 2012.
    • (2012) J Sports Med Phys Fitness , vol.52 , pp. 337-343
    • Tonis, T.1    Gorter, K.2    Vollenbroek-Hutten, M.3    Hermens, H.4
  • 30
    • 1442301553 scopus 로고    scopus 로고
    • Estimation of VO2max from the ratio between HRmax and HRrest-The heart rate ratio method
    • Uth N, Sørensen H, Overgaard K, Pedersen PK. Estimation of VO2max from the ratio between HRmax and HRrest-the heart rate ratio method. Eur J Appl Physiol 91: 111-115, 2004.
    • (2004) Eur J Appl Physiol , vol.91 , pp. 111-115
    • Uth, N.1    Sørensen, H.2    Overgaard, K.3    Pedersen, P.K.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.