메뉴 건너뛰기




Volumn , Issue , 2005, Pages

The impact of statcom on distance relay

Author keywords

Distance relay; FACTS devices; Modelling; Power system protection; STATCOM

Indexed keywords

ELECTRIC CURRENT REGULATORS; ELECTRIC POWER FACTOR CORRECTION; ELECTRIC POWER TRANSMISSION; ELECTRIC RELAYS; FLEXIBLE AC TRANSMISSION SYSTEMS; MODELS; RELAY PROTECTION; STATIC SYNCHRONOUS COMPENSATORS; TRANSMISSION LINE THEORY;

EID: 84983097757     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (16)

References (10)
  • 3
    • 0005966456 scopus 로고
    • Protection requirements for flexible AC transmission system
    • Paris, France
    • M. Adamiak and R. Patterson, "Protection requirements for flexible AC transmission system," in Proc. CIGRE, Paris, France 1992
    • (1992) Proc. CIGRE
    • Adamiak, M.1    Patterson, R.2
  • 4
    • 0032187658 scopus 로고    scopus 로고
    • AEP UPFC project: Installation, commissioning and operation of the ±160 MVA STATCOM (phase I)
    • IEEE Transactions on Oct.
    • Schauder. C. et al, "AEP UPFC project: installation, commissioning and operation of the ±160 MVA STATCOM (phase I)", Power Delivery, IEEE Transactions on, Volume: 13, Issue: 4, Oct. 1998 Pages:1530-1535
    • (1998) Power Delivery , vol.13 , Issue.4 , pp. 1530-1535
    • Schauder, C.1
  • 5
    • 0036529608 scopus 로고    scopus 로고
    • Operation of impedance protection relays with the STATCOM
    • IEEE Transactions on April
    • K. El-Arroudi, G. Joos, D.T. McGillis, "Operation of impedance protection relays with the STATCOM," Power Delivery, IEEE Transactions on, Volume: 17, Issue: 2, April 2002 Pages:381-387.
    • (2002) Power Delivery , vol.17 , Issue.2 , pp. 381-387
    • El-Arroudi, K.1    Joos, G.2    McGillis, D.T.3
  • 6
    • 0033692106 scopus 로고    scopus 로고
    • Adaptive relay setting for flexible AC transmission systems (FACTS)
    • IEEE Transactions on Jan
    • P.K. Dash., A.K. Pradhan, G. Panda, A.C. Liew, "Adaptive relay setting for flexible AC transmission systems (FACTS)," Power Delivery, IEEE Transactions on, Volume: 15 Issue: 1, Jan 2000 Page(s): 38-43
    • (2000) Power Delivery , vol.15 , Issue.1 , pp. 38-43
    • Dash, P.K.1    Pradhan, A.K.2    Panda, G.3    Liew, A.C.4
  • 7
    • 84979745186 scopus 로고    scopus 로고
    • The impact of TCSC on distance protection relay
    • Proceedings. POWERCON '98. 1998 International Conference on 18-21 Aug.
    • W. G. Wang; X.G. Yin; J. Yu; X. ZH Duan; D. SH Chen "The impact of TCSC on distance protection relay," Power System Technology, 1998. Proceedings. POWERCON '98. 1998 International Conference on, Volume: 1, 18-21 Aug. 1998
    • (1998) Power System Technology, 1998 , vol.1
    • Wang, W.G.1    Yin, X.G.2    Yu, J.3    Zh Duan, X.4    Chen, D.5
  • 9
    • 84954410807 scopus 로고    scopus 로고
    • Digital simulation of power systems and power electronics using the MATLAB/Simulink power system blockset
    • IEEE 23-27 Jan. Vol. 4
    • G. Sybille, Le-Huy. Hoang "Digital simulation of power systems and power electronics using the MATLAB/Simulink Power System Blockset" Power Engineering Society Winter Meeting, 2000. IEEE, Volume: 4, 23-27 Jan. 2000 Pages: 2973-2981 Vol. 4
    • (2000) Power Engineering Society Winter Meeting, 2000 , vol.4 , pp. 2973-2981
    • Sybille, G.1    Hoang, L.-H.2
  • 10
    • 0032647271 scopus 로고    scopus 로고
    • STATCOM-STATic synchronous COMpensator: Theory, modeling, and applications
    • IEEE 31 Jan-4 Feb
    • Sen, K.K "STATCOM-STATic synchronous COMpensator: theory, modeling, and applications."; Power Engineering Society 1999 Winter Meeting, IEEE, Volume: 2, 31 Jan-4 Feb 1999 Pages: 1177-1183
    • (1999) Power Engineering Society 1999 Winter Meeting , vol.2 , pp. 1177-1183
    • Sen, K.K.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.