메뉴 건너뛰기




Volumn 2016-June, Issue , 2016, Pages

Pulse rate variability and blood oxidation content identification using miniature wearable wrist device

Author keywords

blood oxidation; embedded system; heart rate; identification; photoplethysmography; pulse rate; variability

Indexed keywords

BIOMETRICS; BLOOD; EMBEDDED SYSTEMS; IDENTIFICATION (CONTROL SYSTEMS); OXIDATION; PHOTOPLETHYSMOGRAPHY; WEARABLE COMPUTERS; WEARABLE TECHNOLOGY;

EID: 84978802761     PISSN: 21578672     EISSN: 21578702     Source Type: Conference Proceeding    
DOI: 10.1109/IWSSIP.2016.7502766     Document Type: Conference Paper
Times cited : (30)

References (14)
  • 2
    • 16444377933 scopus 로고    scopus 로고
    • Heart rate variability: Measurement and clinical utility
    • R. E. Kleiger, P. K. Stein, and J. T. Bigger, "Heart rate variability: Measurement and clinical utility, " Ann. Noninvasive Electrocardiol., vol. 10, no. 1, pp. 88-101, 2005.
    • (2005) Ann. Noninvasive Electrocardiol. , vol.10 , Issue.1 , pp. 88-101
    • Kleiger, R.E.1    Stein, P.K.2    Bigger, J.T.3
  • 3
    • 6344251621 scopus 로고    scopus 로고
    • Heart rate variability: A noninvasive electrocardiographic method to measure the autonomic nervous system
    • J. Sztajzel, "Heart rate variability: A noninvasive electrocardiographic method to measure the autonomic nervous system, " Swiss Med. Wkly., vol. 134, no. 35-36, pp. 514-522, 2004.
    • (2004) Swiss Med. Wkly. , vol.134 , Issue.35-36 , pp. 514-522
    • Sztajzel, J.1
  • 5
    • 0038458908 scopus 로고    scopus 로고
    • Heart rate monitoring: Applications and limitations
    • J. Achten and A. E. Jeukendrup, "Heart rate monitoring: applications and limitations, " Sports Med., vol. 33, no. 7, pp. 517-538, 2003.
    • (2003) Sports Med. , vol.33 , Issue.7 , pp. 517-538
    • Achten, J.1    Jeukendrup, A.E.2
  • 6
    • 84857719533 scopus 로고    scopus 로고
    • Non-invasive measurement of blood components: Sensor for an in vivo hemoglobin measurement
    • J. Kraitl, U. Timm, H. Ewald, and E. Lewis, "Non-invasive measurement of blood components: Sensor for an in vivo hemoglobin measurement, " Proc. Int. Conf. Sens. Technol. ICST, pp. 253-257, 2011.
    • (2011) Proc. Int. Conf. Sens. Technol. ICST , pp. 253-257
    • Kraitl, J.1    Timm, U.2    Ewald, H.3    Lewis, E.4
  • 7
    • 84864204847 scopus 로고    scopus 로고
    • Measuring of oxygen saturation using pulse oximeter based on fuzzy logic
    • G. Ates and K. Polat, "Measuring of oxygen saturation using pulse oximeter based on fuzzy logic, " 2012 IEEE Int. Symp. Med. Meas. Appl. Proc, pp. 1-6, 2012.
    • (2012) 2012 IEEE Int. Symp. Med. Meas. Appl. Proc , pp. 1-6
    • Ates, G.1    Polat, K.2
  • 8
    • 84896743083 scopus 로고    scopus 로고
    • Development of simultaneous monitoring system for non-invasive blood pressure and blood oxygen saturation
    • C. Jian, G. Shumei, and S. Yilin, "Development of simultaneous monitoring system for non-invasive blood pressure and blood oxygen saturation, " 2013 IEEE 11th Int. Conf. Electron. Meas. Instruments, vol. 2, pp. 968-973, 2013.
    • (2013) 2013 IEEE 11th Int. Conf. Electron. Meas. Instruments , vol.2 , pp. 968-973
    • Jian, C.1    Shumei, G.2    Yilin, S.3
  • 12
    • 65949112991 scopus 로고    scopus 로고
    • Flash storage today
    • August
    • A. Leventhal, "Flash Storage Today, " Queue, vol. 6, no. August, p. 24, 2008.
    • (2008) Queue , vol.6 , pp. 24
    • Leventhal, A.1
  • 14
    • 84891682826 scopus 로고    scopus 로고
    • Brezkontaktno merjenje frekvence srcnega utripa ter spremenljivosti frekvence srcnega utripa
    • J. Kranjec, S. Begus, G. Gersak, and J. Drnovsek, "Brezkontaktno merjenje frekvence srcnega utripa ter spremenljivosti frekvence srcnega utripa, " Elektroteh. Vestnik/Electrotechnical Rev., vol. 80, no. 3, pp. 135-140, 2013.
    • (2013) Elektroteh. Vestnik/Electrotechnical Rev. , vol.80 , Issue.3 , pp. 135-140
    • Kranjec, J.1    Begus, S.2    Gersak, G.3    Drnovsek, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.