메뉴 건너뛰기




Volumn 17, Issue 7, 2016, Pages 561-567

Femoral indicator injection for transpulmonary thermodilution using the EV1000/VolumeView®: do the same criteria apply as for the PiCCO®?

Author keywords

Central venous catheter; EV1000 VolumeView ; Femoral vein; Global end diastolic volume; Hemodynamic monitoring; Jugular vein; PiCCO ; Transpulmonary thermodilution

Indexed keywords

AGED; ARTICLE; BLOOD VESSEL PERMEABILITY; CASE REPORT; CENTRAL VENOUS CATHETER; COMPARATIVE STUDY; DIALYSIS CATHETER; FEMALE; FEMORAL VEIN; FIBEROPTIC OXIMETER CATHETER; GLOBAL EJECTION FRACTION; GLOBAL END DIASTOLIC VOLUME INDEX; HEART INDEX; HEMODYNAMIC PARAMETERS; HUMAN; HYPOVOLEMIC SHOCK; JUGULAR VEIN; MEASUREMENT ERROR; PRIORITY JOURNAL; PULMONARY VASCULAR PERMEABILITY INDEX; THERMODILUTION; THERMODILUTION DEVICE; VASCULAR ACCESS; VERY ELDERLY; CAPILLARY PERMEABILITY; DEVICES; HEART STROKE VOLUME; INJECTION; LUNG VOLUME; PROCEDURES;

EID: 84978743201     PISSN: 16731581     EISSN: 18621783     Source Type: Journal    
DOI: 10.1631/jzus.B1500244     Document Type: Article
Times cited : (11)

References (20)
  • 1
    • 78549250767 scopus 로고    scopus 로고
    • Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water
    • PID: 21092252
    • Bendjelid, K., Giraud, R., Siegenthaler, N., et al., 2010. Validation of a new transpulmonary thermodilution system to assess global end-diastolic volume and extravascular lung water. Crit. Care, 14(6):R209. http://dx.doi.org/10.1186/cc9332
    • (2010) Crit. Care , vol.14 , Issue.6 , pp. R209
    • Bendjelid, K.1    Giraud, R.2    Siegenthaler, N.3
  • 2
    • 84887731414 scopus 로고    scopus 로고
    • Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients
    • COI: 1:STN:280:DC%2BC3srovFentw%3D%3D, PID: 23625132
    • Bendjelid, K., Marx, G., Kiefer, N., et al., 2013. Performance of a new pulse contour method for continuous cardiac output monitoring: validation in critically ill patients. Br. J. Anaesth., 111(4):573–579. http://dx.doi.org/10.1093/bja/aet116
    • (2013) Br. J. Anaesth. , vol.111 , Issue.4 , pp. 573-579
    • Bendjelid, K.1    Marx, G.2    Kiefer, N.3
  • 3
    • 84926213161 scopus 로고    scopus 로고
    • Pulmonary vascular permeability index and global end-diastolic volume: are the data consistent in patients with femoral venous access for transpulmonary thermodilution: a prospective observational study
    • PID: 25928560
    • Berbara, H., Mair, S., Beitz, A., et al., 2014. Pulmonary vascular permeability index and global end-diastolic volume: are the data consistent in patients with femoral venous access for transpulmonary thermodilution: a prospective observational study. BMC Anesthesiol., 14:81. http://dx.doi.org/10.1186/1471-2253-14-81
    • (2014) BMC Anesthesiol. , vol.14 , pp. 81
    • Berbara, H.1    Mair, S.2    Beitz, A.3
  • 4
    • 0032884749 scopus 로고    scopus 로고
    • Measuring agreement in method comparison studies
    • COI: 1:STN:280:DyaK1MvivFOmug%3D%3D, PID: 10501650
    • Bland, J.M., Altman, D.G., 1999. Measuring agreement in method comparison studies. Stat. Methods Med. Res., 8(2):135–160.
    • (1999) Stat. Methods Med. Res. , vol.8 , Issue.2 , pp. 135-160
    • Bland, J.M.1    Altman, D.G.2
  • 5
    • 84920463516 scopus 로고    scopus 로고
    • Assessment of cardiac output with transpulmonary thermodilution during exercise in humans
    • PID: 25359719
    • Calbet, J.A., Boushel, R., 2015. Assessment of cardiac output with transpulmonary thermodilution during exercise in humans. J. Appl. Physiol., 118(1):1–10. http://dx.doi.org/10.1152/japplphysiol.00686.2014
    • (2015) J. Appl. Physiol. , vol.118 , Issue.1 , pp. 1-10
    • Calbet, J.A.1    Boushel, R.2
  • 6
    • 84944705136 scopus 로고    scopus 로고
    • Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre
    • Cho, Y.J., Koo, C.H., Kim, T.K., et al., 2015. Comparison of cardiac output measures by transpulmonary thermodilution, pulse contour analysis, and pulmonary artery thermodilution during off-pump coronary artery bypass surgery: a subgroup analysis of the cardiovascular anaesthesia registry at a single tertiary centre. J. Clin. Monit. Comput., online first. http://dx.doi.org/10.1007/s10877-015-9784-6
    • (2015) J. Clin. Monit. Comput.
    • Cho, Y.J.1    Koo, C.H.2    Kim, T.K.3
  • 7
    • 0033003166 scopus 로고    scopus 로고
    • A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques
    • COI: 1:STN:280:DC%2BD3s%2FmslCruw%3D%3D, PID: 12578081
    • Critchley, L.A., Critchley, J.A., 1999. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J. Clin. Monit. Comput., 15(2):85–91. http://dx.doi.org/10.1023/A:1009982611386
    • (1999) J. Clin. Monit. Comput. , vol.15 , Issue.2 , pp. 85-91
    • Critchley, L.A.1    Critchley, J.A.2
  • 8
    • 12244306921 scopus 로고    scopus 로고
    • The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population
    • PID: 15644643
    • Deshpande, K.S., Hatem, C., Ulrich, H.L., et al., 2005. The incidence of infectious complications of central venous catheters at the subclavian, internal jugular, and femoral sites in an intensive care unit population. Crit. Care Med., 33(1):13–20, discussion 234-235. http://dx.doi.org/10.1097/01.CCM.0000149838.47048.60
    • (2005) Crit. Care Med. , vol.33 , Issue.1 , pp. 13-20
    • Deshpande, K.S.1    Hatem, C.2    Ulrich, H.L.3
  • 9
    • 33846323221 scopus 로고    scopus 로고
    • Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients
    • PID: 17119923
    • Goepfert, M.S.G., Reuter, D.A., Akyol, D., et al., 2007. Goal-directed fluid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med., 33(1):96–103. http://dx.doi.org/10.1007/s00134-006-0404-2
    • (2007) Intensive Care Med. , vol.33 , Issue.1 , pp. 96-103
    • Goepfert, M.S.G.1    Reuter, D.A.2    Akyol, D.3
  • 10
    • 46149110753 scopus 로고    scopus 로고
    • Influence of insertion site on central venous catheter colonization and bloodstream infection rates
    • PID: 18317732
    • Gowardman, J.R., Robertson, I.K., Parkes, S., et al., 2008. Influence of insertion site on central venous catheter colonization and bloodstream infection rates. Intensive Care Med., 34(6):1038–1045. http://dx.doi.org/10.1007/s00134-008-1046-3
    • (2008) Intensive Care Med. , vol.34 , Issue.6 , pp. 1038-1045
    • Gowardman, J.R.1    Robertson, I.K.2    Parkes, S.3
  • 11
    • 84873364233 scopus 로고    scopus 로고
    • Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome
    • PID: 23263578
    • Jozwiak, M., Silva, S., Persichini, R., et al., 2013. Extravascular lung water is an independent prognostic factor in patients with acute respiratory distress syndrome. Crit. Care Med., 41(2):472–480. http://dx.doi.org/10.1097/CCM.0b013e31826ab377
    • (2013) Crit. Care Med. , vol.41 , Issue.2 , pp. 472-480
    • Jozwiak, M.1    Silva, S.2    Persichini, R.3
  • 12
    • 84861553874 scopus 로고    scopus 로고
    • Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters
    • PID: 22647561
    • Kiefer, N., Hofer, C.K., Marx, G., et al., 2012. Clinical validation of a new thermodilution system for the assessment of cardiac output and volumetric parameters. Crit. Care, 16(3):R98. http://dx.doi.org/10.1186/cc11366
    • (2012) Crit. Care , vol.16 , Issue.3 , pp. R98
    • Kiefer, N.1    Hofer, C.K.2    Marx, G.3
  • 13
    • 33744506105 scopus 로고    scopus 로고
    • Extravascular lung water determined with single transpulmonary thermodilution correlates with the severity of sepsis-induced acute lung injury
    • PID: 16625129
    • Kuzkov, V.V., Kirov, M.Y., Sovershaev, M.A., et al., 2006. Extravascular lung water determined with single transpulmonary thermodilution correlates with the severity of sepsis-induced acute lung injury. Crit. Care Med., 34(6):1647–1653. http://dx.doi.org/10.1097/01.CCM.0000218817.24208.2E
    • (2006) Crit. Care Med. , vol.34 , Issue.6 , pp. 1647-1653
    • Kuzkov, V.V.1    Kirov, M.Y.2    Sovershaev, M.A.3
  • 14
    • 77950511663 scopus 로고    scopus 로고
    • Global and right ventricular end-diastolic volumes correlate better with preload after correction for ejection fraction
    • COI: 1:STN:280:DC%2BC3c3osVOjsw%3D%3D, PID: 20085545
    • Malbrain, M.L., de Potter, T.J., Dits, H., et al., 2010. Global and right ventricular end-diastolic volumes correlate better with preload after correction for ejection fraction. Acta Anaesthesiol. Scand., 54(5):622–631. http://dx.doi.org/10.1111/j.1399-6576.2009.02202.x
    • (2010) Acta Anaesthesiol. Scand. , vol.54 , Issue.5 , pp. 622-631
    • Malbrain, M.L.1    de Potter, T.J.2    Dits, H.3
  • 15
    • 0242468625 scopus 로고    scopus 로고
    • Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock
    • PID: 14605066
    • Michard, F., Alaya, S., Zarka, V., et al., 2003. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest, 124(5):1900–1908. http://dx.doi.org/10.1378/chest.124.5.1900
    • (2003) Chest , vol.124 , Issue.5 , pp. 1900-1908
    • Michard, F.1    Alaya, S.2    Zarka, V.3
  • 16
    • 34648825072 scopus 로고    scopus 로고
    • Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions
    • PID: 17905268
    • Renner, J., Gruenewald, M., Brand, P., et al., 2007. Global end-diastolic volume as a variable of fluid responsiveness during acute changing loading conditions. J. Cardiothorac. Vasc. Anesth., 21(5):650–654. http://dx.doi.org/10.1053/j.jvca.2007.05.006
    • (2007) J. Cardiothorac. Vasc. Anesth. , vol.21 , Issue.5 , pp. 650-654
    • Renner, J.1    Gruenewald, M.2    Brand, P.3
  • 17
    • 77952511173 scopus 로고    scopus 로고
    • Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter
    • PID: 20500825
    • Saugel, B., Umgelter, A., Schuster, T., et al., 2010. Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter. Crit. Care, 14:R95. http://dx.doi.org/10.1186/cc9030
    • (2010) Crit. Care , vol.14 , pp. R95
    • Saugel, B.1    Umgelter, A.2    Schuster, T.3
  • 18
    • 33947104274 scopus 로고    scopus 로고
    • Effect of the venous catheter site on transpulmonary thermodilution measurement variables
    • PID: 17255873
    • Schmidt, S., Westhoff, T.H., Hofmann, C., et al., 2007. Effect of the venous catheter site on transpulmonary thermodilution measurement variables. Crit. Care Med., 35(3): 783–786. http://dx.doi.org/10.1097/01.CCM.0000256720.11360.FB
    • (2007) Crit. Care Med. , vol.35 , Issue.3 , pp. 783-786
    • Schmidt, S.1    Westhoff, T.H.2    Hofmann, C.3
  • 19
    • 84943658396 scopus 로고    scopus 로고
    • The effects of fluid resuscitation according to PiCCO on the early stage of severe acute pancreatitis
    • PID: 26160657
    • Sun, Y., Lu, Z.H., Zhang, X.S., et al., 2015. The effects of fluid resuscitation according to PiCCO on the early stage of severe acute pancreatitis. Pancreatology, 15(5):497–502. http://dx.doi.org/10.1016/j.pan.2015.06.006
    • (2015) Pancreatology , vol.15 , Issue.5 , pp. 497-502
    • Sun, Y.1    Lu, Z.H.2    Zhang, X.S.3
  • 20
    • 84959565540 scopus 로고    scopus 로고
    • Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables
    • Yu, W.Q., Zhang, Y., Zhang, S.Y., et al., 2016. Impact of misplaced subclavian vein catheter into jugular vein on transpulmonary thermodilution measurement variables. J. Zhejiang Univ.-Sci. B (Biomed. & Biotechnol.), 17(1):60–66. http://dx.doi.org/10.1631/jzus.B1500167
    • (2016) J. Zhejiang Univ.-Sci. B (Biomed. & Biotechnol.) , vol.17 , Issue.1 , pp. 60-66
    • Yu, W.Q.1    Zhang, Y.2    Zhang, S.Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.