메뉴 건너뛰기




Volumn 67, Issue 7, 2016, Pages 751-762

Safety and efficacy of everolimus- versus sirolimus-eluting stents 5-year results from SORT OUT IV

Author keywords

drug eluting stent(s); outcome; percutaneous coronary intervention; very late definite stent thrombosis

Indexed keywords

ADULT; ARTICLE; CLINICAL EFFECTIVENESS; CONTROLLED STUDY; DEVICE SAFETY; EVEROLIMUS ELUTING CORONARY STENT; FEMALE; HEART DEATH; HEART INFARCTION; HIGH RISK PATIENT; HUMAN; MAJOR ADVERSE CARDIAC EVENT; MAJOR CLINICAL STUDY; MALE; MIDDLE AGED; MULTICENTER STUDY; OUTCOME ASSESSMENT; PRIORITY JOURNAL; RANDOMIZED CONTROLLED TRIAL; RISK ASSESSMENT; SIROLIMUS ELUTING CORONARY STENT; STENT THROMBOSIS; TARGET VESSEL REVASCULARIZATION; CLINICAL TRIAL; CORONARY ARTERY DISEASE; DENMARK; DRUG ELUTING STENT; FOLLOW UP; INCIDENCE; KAPLAN MEIER METHOD; PERCUTANEOUS CORONARY INTERVENTION; POSTOPERATIVE COMPLICATIONS; PROCEDURES; PROSTHESIS DESIGN; RETROSPECTIVE STUDY; SINGLE BLIND PROCEDURE; SURVIVAL RATE; TIME FACTOR; TREATMENT OUTCOME; TRENDS;

EID: 84977456233     PISSN: 07351097     EISSN: 15583597     Source Type: Journal    
DOI: 10.1016/j.jacc.2015.11.051     Document Type: Article
Times cited : (112)

References (32)
  • 1
    • 0037030658 scopus 로고    scopus 로고
    • A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • M.C. Morice, P.W. Serruys, J.E. Sousa, and et al. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization N Engl J Med 346 2002 1773 1780
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3
  • 2
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • J.W. Moses, M.B. Leon, J.J. Popma, and et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery N Engl J Med 349 2003 1315 1323
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 3
    • 9144249927 scopus 로고    scopus 로고
    • A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease
    • G.W. Stone, S.G. Ellis, D.A. Cox, and et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease N Engl J Med 350 2004 221 231
    • (2004) N Engl J Med , vol.350 , pp. 221-231
    • Stone, G.W.1    Ellis, S.G.2    Cox, D.A.3
  • 4
    • 77956192634 scopus 로고    scopus 로고
    • Paclitaxel and sirolimus eluting stents versus bare metal stents: Long-term risk of stent thrombosis and other outcomes. from the Western Denmark Heart Registry
    • L.O. Jensen, H.H. Tilsted, P. Thayssen, and et al. Paclitaxel and sirolimus eluting stents versus bare metal stents: long-term risk of stent thrombosis and other outcomes. From the Western Denmark Heart Registry EuroIntervention 5 2010 898 905
    • (2010) EuroIntervention , vol.5 , pp. 898-905
    • Jensen, L.O.1    Tilsted, H.H.2    Thayssen, P.3
  • 5
    • 79959502100 scopus 로고    scopus 로고
    • 2-year follow-up of a randomized controlled trial of everolimus- and paclitaxel-eluting stents for coronary revascularization in daily practice. COMPARE (Comparison of the everolimus eluting XIENCE-V stent with the paclitaxel eluting TAXUS LIBERTE stent in all-comers: A randomized open label trial)
    • P.C. Smits, E. Kedhi, K.J. Royaards, and et al. 2-year follow-up of a randomized controlled trial of everolimus- and paclitaxel-eluting stents for coronary revascularization in daily practice. COMPARE (Comparison of the everolimus eluting XIENCE-V stent with the paclitaxel eluting TAXUS LIBERTE stent in all-comers: a randomized open label trial) J Am Coll Cardiol 58 2011 11 18
    • (2011) J Am Coll Cardiol , vol.58 , pp. 11-18
    • Smits, P.C.1    Kedhi, E.2    Royaards, K.J.3
  • 6
    • 79959508607 scopus 로고    scopus 로고
    • Randomized comparison of everolimus- and paclitaxel-eluting stents. 2-year follow-up from the SPIRIT (Clinical Evaluation of the XIENCE v Everolimus Eluting Coronary Stent System) IV trial
    • G.W. Stone, A. Rizvi, K. Sudhir, and et al. Randomized comparison of everolimus- and paclitaxel-eluting stents. 2-year follow-up from the SPIRIT (Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System) IV trial J Am Coll Cardiol 58 2011 19 25
    • (2011) J Am Coll Cardiol , vol.58 , pp. 19-25
    • Stone, G.W.1    Rizvi, A.2    Sudhir, K.3
  • 7
    • 84858377141 scopus 로고    scopus 로고
    • Randomized comparison of everolimus-eluting and sirolimus-eluting stents in patients treated with percutaneous coronary intervention: The Scandinavian Organization for Randomized Trials with Clinical Outcomes IV (SORT OUT IV)
    • L.O. Jensen, P. Thayssen, H.S. Hansen, and et al. Randomized comparison of everolimus-eluting and sirolimus-eluting stents in patients treated with percutaneous coronary intervention: the Scandinavian Organization for Randomized Trials with Clinical Outcomes IV (SORT OUT IV) Circulation 125 2012 1246 1255
    • (2012) Circulation , vol.125 , pp. 1246-1255
    • Jensen, L.O.1    Thayssen, P.2    Hansen, H.S.3
  • 8
    • 77950300349 scopus 로고    scopus 로고
    • Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): A randomised controlled superiority trial
    • K. Rasmussen, M. Maeng, A. Kaltoft, and et al. Efficacy and safety of zotarolimus-eluting and sirolimus-eluting coronary stents in routine clinical care (SORT OUT III): a randomised controlled superiority trial Lancet 375 2010 1090 1099
    • (2010) Lancet , vol.375 , pp. 1090-1099
    • Rasmussen, K.1    Maeng, M.2    Kaltoft, A.3
  • 9
    • 77954392890 scopus 로고    scopus 로고
    • Comparison of zotarolimus-eluting and everolimus-eluting coronary stents
    • P.W. Serruys, S. Silber, S. Garg, and et al. Comparison of zotarolimus-eluting and everolimus-eluting coronary stents N Engl J Med 363 2010 136 146
    • (2010) N Engl J Med , vol.363 , pp. 136-146
    • Serruys, P.W.1    Silber, S.2    Garg, S.3
  • 10
    • 84859586982 scopus 로고    scopus 로고
    • Stent thrombosis with drug-eluting and bare-metal stents: Evidence from a comprehensive network meta-analysis
    • T. Palmerini, G. Biondi-Zoccai, R.D. Della, and et al. Stent thrombosis with drug-eluting and bare-metal stents: evidence from a comprehensive network meta-analysis Lancet 379 2012 1393 1402
    • (2012) Lancet , vol.379 , pp. 1393-1402
    • Palmerini, T.1    Biondi-Zoccai, G.2    Della, R.D.3
  • 11
    • 84890792687 scopus 로고    scopus 로고
    • 5-year results of a randomized comparison of XIENCE v everolimus-eluting and TAXUS paclitaxel-eluting stents: Final results from the SPIRIT III trial (clinical evaluation of the XIENCE v everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions)
    • H. Gada, A.J. Kirtane, W. Newman, and et al. 5-year results of a randomized comparison of XIENCE V everolimus-eluting and TAXUS paclitaxel-eluting stents: final results from the SPIRIT III trial (clinical evaluation of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions) JACC Cardiovasc Interv 6 2013 1263 1266
    • (2013) JACC Cardiovasc Interv , vol.6 , pp. 1263-1266
    • Gada, H.1    Kirtane, A.J.2    Newman, W.3
  • 12
    • 84902303806 scopus 로고    scopus 로고
    • Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study): A multicentre, open-label, randomised superiority trial
    • M. Maeng, H.H. Tilsted, L.O. Jensen, and et al. Differential clinical outcomes after 1 year versus 5 years in a randomised comparison of zotarolimus-eluting and sirolimus-eluting coronary stents (the SORT OUT III study): a multicentre, open-label, randomised superiority trial Lancet 383 2014 2047 2056
    • (2014) Lancet , vol.383 , pp. 2047-2056
    • Maeng, M.1    Tilsted, H.H.2    Jensen, L.O.3
  • 13
    • 82755195016 scopus 로고    scopus 로고
    • Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial
    • G.G. Stefanini, B. Kalesan, P.W. Serruys, and et al. Long-term clinical outcomes of biodegradable polymer biolimus-eluting stents versus durable polymer sirolimus-eluting stents in patients with coronary artery disease (LEADERS): 4 year follow-up of a randomised non-inferiority trial Lancet 378 2011 1940 1948
    • (2011) Lancet , vol.378 , pp. 1940-1948
    • Stefanini, G.G.1    Kalesan, B.2    Serruys, P.W.3
  • 14
    • 84898950220 scopus 로고    scopus 로고
    • 4-year clinical outcomes and predictors of repeat revascularization in patients treated with new-generation drug-eluting stents: A report from the RESOLUTE All-Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent with an Everolimus-Eluting Stent for Percutaneous Coronary Intervention)
    • M. Taniwaki, G.G. Stefanini, S. Silber, and et al. 4-year clinical outcomes and predictors of repeat revascularization in patients treated with new-generation drug-eluting stents: a report from the RESOLUTE All-Comers trial (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) J Am Coll Cardiol 63 2014 1617 1625
    • (2014) J Am Coll Cardiol , vol.63 , pp. 1617-1625
    • Taniwaki, M.1    Stefanini, G.G.2    Silber, S.3
  • 15
    • 84918781319 scopus 로고    scopus 로고
    • Endeavor zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent: 4 year results of the PROTECT randomized trial
    • W. Wijns, P.G. Steg, L. Mauri, and et al. Endeavor zotarolimus-eluting stent reduces stent thrombosis and improves clinical outcomes compared with cypher sirolimus-eluting stent: 4 year results of the PROTECT randomized trial Eur Heart J 35 2014 2812 2820
    • (2014) Eur Heart J , vol.35 , pp. 2812-2820
    • Wijns, W.1    Steg, P.G.2    Mauri, L.3
  • 16
    • 53149141718 scopus 로고    scopus 로고
    • Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): A randomised non-inferiority trial
    • S. Windecker, P.W. Serruys, S. Wandel, and et al. Biolimus-eluting stent with biodegradable polymer versus sirolimus-eluting stent with durable polymer for coronary revascularisation (LEADERS): a randomised non-inferiority trial Lancet 372 2008 1163 1173
    • (2008) Lancet , vol.372 , pp. 1163-1173
    • Windecker, S.1    Serruys, P.W.2    Wandel, S.3
  • 17
    • 84906791962 scopus 로고    scopus 로고
    • Three-year outcomes after revascularization with everolimus- and sirolimus-eluting stents from the SORT OUT IV trial
    • L.O. Jensen, P. Thayssen, M. Maeng, and et al. Three-year outcomes after revascularization with everolimus- and sirolimus-eluting stents from the SORT OUT IV trial J Am Coll Cardiol Intv 7 2014 840 848
    • (2014) J Am Coll Cardiol Intv , vol.7 , pp. 840-848
    • Jensen, L.O.1    Thayssen, P.2    Maeng, M.3
  • 18
    • 77952966080 scopus 로고    scopus 로고
    • Rationale and design of a randomized clinical comparison of everolimus-Eluting (Xience V/Promus) and sirolimus-Eluting (cypher select+) coronary stents in unselected patients with coronary heart disease
    • L.O. Jensen, P. Thayssen, H.H. Tilsted, and et al. Rationale and design of a randomized clinical comparison of everolimus-Eluting (Xience V/Promus) and sirolimus-Eluting (cypher select+) coronary stents in unselected patients with coronary heart disease Cardiology 116 2010 73 78
    • (2010) Cardiology , vol.116 , pp. 73-78
    • Jensen, L.O.1    Thayssen, P.2    Tilsted, H.H.3
  • 19
    • 34247558672 scopus 로고    scopus 로고
    • Clinical end points in coronary stent trials: A case for standardized definitions
    • D.E. Cutlip, S. Windecker, R. Mehran, and et al. Clinical end points in coronary stent trials: a case for standardized definitions Circulation 115 2007 2344 2351
    • (2007) Circulation , vol.115 , pp. 2344-2351
    • Cutlip, D.E.1    Windecker, S.2    Mehran, R.3
  • 20
    • 84874441236 scopus 로고    scopus 로고
    • Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): A randomised non-inferiority trial
    • E.H. Christiansen, L.O. Jensen, P. Thayssen, and et al. Biolimus-eluting biodegradable polymer-coated stent versus durable polymer-coated sirolimus-eluting stent in unselected patients receiving percutaneous coronary intervention (SORT OUT V): a randomised non-inferiority trial Lancet 381 2013 661 669
    • (2013) Lancet , vol.381 , pp. 661-669
    • Christiansen, E.H.1    Jensen, L.O.2    Thayssen, P.3
  • 21
    • 0033616908 scopus 로고    scopus 로고
    • Estimation of failure probabilities in the presence of competing risks: New representations of old estimators
    • T.A. Gooley, W. Leisenring, J. Crowley, and B.E. Storer Estimation of failure probabilities in the presence of competing risks: new representations of old estimators Stat Med 18 1999 695 706
    • (1999) Stat Med , vol.18 , pp. 695-706
    • Gooley, T.A.1    Leisenring, W.2    Crowley, J.3    Storer, B.E.4
  • 22
    • 84884360751 scopus 로고    scopus 로고
    • Meta-analysis of everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease: Final 3-year results of the SPIRIT clinical trials program (Clinical Evaluation of the Xience v Everolimus Eluting Coronary Stent System in the Treatment of Patients with de Novo Native Coronary Artery Lesions)
    • G.D. Dangas, P.W. Serruys, D.J. Kereiakes, and et al. Meta-analysis of everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease: final 3-year results of the SPIRIT clinical trials program (Clinical Evaluation of the Xience V Everolimus Eluting Coronary Stent System in the Treatment of Patients With De Novo Native Coronary Artery Lesions) J Am Coll Cardiol Intv 6 2013 914 922
    • (2013) J Am Coll Cardiol Intv , vol.6 , pp. 914-922
    • Dangas, G.D.1    Serruys, P.W.2    Kereiakes, D.J.3
  • 23
    • 79956278957 scopus 로고    scopus 로고
    • Late-term clinical outcomes with zotarolimus- and sirolimus-eluting stents. 5-year follow-up of the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in de Novo Native Coronary Artery Lesions)
    • D.E. Kandzari, L. Mauri, J.J. Popma, and et al. Late-term clinical outcomes with zotarolimus- and sirolimus-eluting stents. 5-year follow-up of the ENDEAVOR III (A Randomized Controlled Trial of the Medtronic Endeavor Drug [ABT-578] Eluting Coronary Stent System Versus the Cypher Sirolimus-Eluting Coronary Stent System in De Novo Native Coronary Artery Lesions) J Am Coll Cardiol Intv 4 2011 543 550
    • (2011) J Am Coll Cardiol Intv , vol.4 , pp. 543-550
    • Kandzari, D.E.1    Mauri, L.2    Popma, J.J.3
  • 24
    • 79959494161 scopus 로고    scopus 로고
    • Five-year clinical and angiographic outcomes of a randomized comparison of sirolimus-eluting and paclitaxel-eluting stents: Results of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization LATE trial
    • L. Raber, L. Wohlwend, M. Wigger, and et al. Five-year clinical and angiographic outcomes of a randomized comparison of sirolimus-eluting and paclitaxel-eluting stents: results of the Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization LATE trial Circulation 123 2011 2819 2828
    • (2011) Circulation , vol.123 , pp. 2819-2828
    • Raber, L.1    Wohlwend, L.2    Wigger, M.3
  • 25
    • 84882803077 scopus 로고    scopus 로고
    • Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: Final 5-year report of the LEADERS (Limus Eluted from A Durable Versus ERodable Stent Coating) randomized, noninferiority trial
    • P.W. Serruys, V. Farooq, B. Kalesan, and et al. Improved safety and reduction in stent thrombosis associated with biodegradable polymer-based biolimus-eluting stents versus durable polymer-based sirolimus-eluting stents in patients with coronary artery disease: final 5-year report of the LEADERS (Limus Eluted From A Durable Versus ERodable Stent Coating) randomized, noninferiority trial J Am Coll Cardiol Intv 6 2013 777 789
    • (2013) J Am Coll Cardiol Intv , vol.6 , pp. 777-789
    • Serruys, P.W.1    Farooq, V.2    Kalesan, B.3
  • 26
    • 84872154794 scopus 로고    scopus 로고
    • The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation
    • P. Thayssen, L.O. Jensen, J.F. Lassen, and et al. The risk and prognostic impact of definite stent thrombosis or in-stent restenosis after coronary stent implantation EuroIntervention 8 2012 591 598
    • (2012) EuroIntervention , vol.8 , pp. 591-598
    • Thayssen, P.1    Jensen, L.O.2    Lassen, J.F.3
  • 27
    • 84929884068 scopus 로고    scopus 로고
    • Duration of dual antiplatelet therapy after drug-eluting stent implantation: A systematic review and meta-analysis of randomized controlled trials
    • G. Giustino, U. Baber, S. Sartori, and et al. Duration of dual antiplatelet therapy after drug-eluting stent implantation: a systematic review and meta-analysis of randomized controlled trials J Am Coll Cardiol 65 2015 1298 1310
    • (2015) J Am Coll Cardiol , vol.65 , pp. 1298-1310
    • Giustino, G.1    Baber, U.2    Sartori, S.3
  • 28
    • 77951868945 scopus 로고    scopus 로고
    • Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease
    • G.W. Stone, A. Rizvi, W. Newman, and et al. Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease N Engl J Med 362 2010 1663 1674
    • (2010) N Engl J Med , vol.362 , pp. 1663-1674
    • Stone, G.W.1    Rizvi, A.2    Newman, W.3
  • 29
    • 84888638226 scopus 로고    scopus 로고
    • Everolimus-eluting stents in patients undergoing percutaneous coronary intervention: Final 3-year results of the Clinical Evaluation of the XIENCE v Everolimus Eluting Coronary Stent System in the Treatment of Subjects with de Novo Native Coronary Artery Lesions trial
    • S.J. Brener, D.J. Kereiakes, C.A. Simonton, and et al. Everolimus-eluting stents in patients undergoing percutaneous coronary intervention: final 3-year results of the Clinical Evaluation of the XIENCE V Everolimus Eluting Coronary Stent System in the Treatment of Subjects With de Novo Native Coronary Artery Lesions trial Am Heart J 166 2013 1035 1042
    • (2013) Am Heart J , vol.166 , pp. 1035-1042
    • Brener, S.J.1    Kereiakes, D.J.2    Simonton, C.A.3
  • 30
    • 84884401830 scopus 로고    scopus 로고
    • Event detection using population-based health care databases in randomized clinical trials: A novel research tool in interventional cardiology
    • L. Thuesen, L.O. Jensen, H.H. Tilsted, and et al. Event detection using population-based health care databases in randomized clinical trials: a novel research tool in interventional cardiology Clin Epidemiol 5 2013 357 361
    • (2013) Clin Epidemiol , vol.5 , pp. 357-361
    • Thuesen, L.1    Jensen, L.O.2    Tilsted, H.H.3
  • 31
    • 84886258945 scopus 로고    scopus 로고
    • Thrombus aspiration during ST-segment elevation myocardial infarction
    • O. Frobert, B. Lagerqvist, G.K. Olivecrona, and et al. Thrombus aspiration during ST-segment elevation myocardial infarction N Engl J Med 369 2013 1587 1597
    • (2013) N Engl J Med , vol.369 , pp. 1587-1597
    • Frobert, O.1    Lagerqvist, B.2    Olivecrona, G.K.3
  • 32
    • 77950296974 scopus 로고    scopus 로고
    • Sorting out drug-eluting stents
    • M.W. Webster, and J.A. Ormiston Sorting out drug-eluting stents Lancet 375 2010 1060 1062
    • (2010) Lancet , vol.375 , pp. 1060-1062
    • Webster, M.W.1    Ormiston, J.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.