메뉴 건너뛰기




Volumn 84, Issue , 2017, Pages 261-266

The behavior of different transformer oils relating to the generation of fault gases after electrical flashovers

Author keywords

Dissolved gas analysis; Electrical flashover; Fault gases; Transformer oil

Indexed keywords

DISSOLUTION; ELECTRIC TRANSFORMER TESTING; FLAMMABILITY TESTING; FLASHOVER; GAS CHROMATOGRAPHY; HYDROCARBONS; INSULATING OIL; OIL FILLED TRANSFORMERS;

EID: 84976439834     PISSN: 01420615     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ijepes.2016.06.007     Document Type: Article
Times cited : (9)

References (18)
  • 1
    • 0027403807 scopus 로고
    • Static headspace gas chromatographic determination of fault gases dissolved in transformer insulating oils
    • [1] Leblanc, Y., Gilbert, R., Duval, M., Hubert, J., Static headspace gas chromatographic determination of fault gases dissolved in transformer insulating oils. J Chromatogr A 633 (1993), 185–193.
    • (1993) J Chromatogr A , vol.633 , pp. 185-193
    • Leblanc, Y.1    Gilbert, R.2    Duval, M.3    Hubert, J.4
  • 2
    • 84976369228 scopus 로고    scopus 로고
    • Mineral oil-impregnated electrical equipment in service – guide to the interpretation of dissolved and free gases analysis
    • International Electrotechnical Commission. International Standard IEC 60599:1999 + A1:2007, Edition 2, 1999 consolidated with amendment 1
    • [2] International Electrotechnical Commission. International Standard IEC 60599:1999 + A1:2007, Mineral oil-impregnated electrical equipment in service – guide to the interpretation of dissolved and free gases analysis. Edition 2, 1999 consolidated with amendment 1; 2007.
    • (2007)
  • 3
    • 29944439716 scopus 로고    scopus 로고
    • International Electrotechnical Commission
    • International Standard IEC 60567:2011, Oil-filled electrical equipment – sampling of gases and analysis of free and dissolved gases – guidance. Edition 4.0;
    • [3] International Electrotechnical Commission. International Standard IEC 60567:2011, Oil-filled electrical equipment – sampling of gases and analysis of free and dissolved gases – guidance. Edition 4.0; 2011.
    • (2011)
  • 4
    • 84863378779 scopus 로고    scopus 로고
    • A review of dissolved gas analysis in power transformers
    • [4] Sun, H.-C., Huang, Y.-C., Huang, C.-M., A review of dissolved gas analysis in power transformers. Energy Proc 14 (2012), 1220–1225.
    • (2012) Energy Proc , vol.14 , pp. 1220-1225
    • Sun, H.-C.1    Huang, Y.-C.2    Huang, C.-M.3
  • 5
    • 0016057142 scopus 로고
    • Monitoring oil cooling transformers by gas analysis
    • [5] Doernenburg, E., Strittmater, W., Monitoring oil cooling transformers by gas analysis. Brown Boveri Rev 61 (1974), 238–274.
    • (1974) Brown Boveri Rev , vol.61 , pp. 238-274
    • Doernenburg, E.1    Strittmater, W.2
  • 6
    • 47349088026 scopus 로고    scopus 로고
    • Institute of Electrical and Electronics Engineers
    • IEEE Standard C57.104-2008, IEEE guide for the interpretation of gases generated in oil-immersed transformers
    • [6] Institute of Electrical and Electronics Engineers. IEEE Standard C57.104-2008, IEEE guide for the interpretation of gases generated in oil-immersed transformers; 2008.
    • (2008)
  • 7
    • 84976405384 scopus 로고    scopus 로고
    • Fault gases formed in oil-filled breathing EHV power transformers. The interpretation of gas analysis data. IEEE Trans Power Appar Syst 1974;476–8. Conference paper C74
    • [7] Duval M. Fault gases formed in oil-filled breathing EHV power transformers. The interpretation of gas analysis data. IEEE Trans Power Appar Syst 1974;476–8. Conference paper C74.
    • Duval, M.1
  • 8
    • 0024768426 scopus 로고
    • Dissolved gas analysis: it can save your transformer
    • [8] Duval, M., Dissolved gas analysis: it can save your transformer. IEEE Electr Insul Mag 5 (1989), 22–27.
    • (1989) IEEE Electr Insul Mag , vol.5 , pp. 22-27
    • Duval, M.1
  • 9
    • 57849136556 scopus 로고    scopus 로고
    • The duval triangle for load tap changers, non-mineral oils and low temperature faults in transformers
    • [9] Duval, M., The duval triangle for load tap changers, non-mineral oils and low temperature faults in transformers. IEEE Electr Insul Mag 24 (2008), 22–29.
    • (2008) IEEE Electr Insul Mag , vol.24 , pp. 22-29
    • Duval, M.1
  • 10
    • 84908667321 scopus 로고    scopus 로고
    • The duval pentagon – a new complementary tool for the interpretation of dissolved gas analysis in transformers
    • [10] Duval, M., Lamarre, L., The duval pentagon – a new complementary tool for the interpretation of dissolved gas analysis in transformers. IEEE Electr Insul Mag 30 (2014), 9–12.
    • (2014) IEEE Electr Insul Mag , vol.30 , pp. 9-12
    • Duval, M.1    Lamarre, L.2
  • 11
    • 0018021576 scopus 로고
    • IEEE and IEC codes to interpret incipient faults in transformers, using gas in oil analysis
    • [11] Rogers, R.R., IEEE and IEC codes to interpret incipient faults in transformers, using gas in oil analysis. IEEE Trans Electr Insul 13 (1978), 349–354.
    • (1978) IEEE Trans Electr Insul , vol.13 , pp. 349-354
    • Rogers, R.R.1
  • 12
    • 0035481368 scopus 로고    scopus 로고
    • A comparative study of neural network efficiency in power transformers diagnosis using dissolved gas analysis
    • [12] Guardado, J.L., Naredo, J.L., Moreno, P., Fuerte, C.R., A comparative study of neural network efficiency in power transformers diagnosis using dissolved gas analysis. IEEE Trans Power Delivery 16 (2001), 643–647.
    • (2001) IEEE Trans Power Delivery , vol.16 , pp. 643-647
    • Guardado, J.L.1    Naredo, J.L.2    Moreno, P.3    Fuerte, C.R.4
  • 13
    • 27844440423 scopus 로고    scopus 로고
    • Improving the IEC table for transformer failure diagnosis with knowledge extraction from neural networks
    • [13] Miranda, V., Castro, A.R.G., Improving the IEC table for transformer failure diagnosis with knowledge extraction from neural networks. IEEE Trans Power Delivery 20 (2005), 2509–2516.
    • (2005) IEEE Trans Power Delivery , vol.20 , pp. 2509-2516
    • Miranda, V.1    Castro, A.R.G.2
  • 14
    • 84976390012 scopus 로고    scopus 로고
    • Dissolved gas analysis of power transformer using fuzzy clustering and radial basis function neural network
    • [14] Lee, J.P., Lee, D.J., Kim, S.S., Ji, P.S., Lim, J.Y., Dissolved gas analysis of power transformer using fuzzy clustering and radial basis function neural network. J Electr Eng Technol 2 (2007), 157–164.
    • (2007) J Electr Eng Technol , vol.2 , pp. 157-164
    • Lee, J.P.1    Lee, D.J.2    Kim, S.S.3    Ji, P.S.4    Lim, J.Y.5
  • 15
    • 29944439716 scopus 로고    scopus 로고
    • International Electrotechnical Commission
    • International Standard IEC 60156:1995, Insulating liquids – determination of the breakdown voltage at power frequency – test method
    • [15] International Electrotechnical Commission. International Standard IEC 60156:1995, Insulating liquids – determination of the breakdown voltage at power frequency – test method; 1995.
    • (1995)
  • 16
    • 84976353743 scopus 로고    scopus 로고
    • International Electrotechnical Commission
    • International Standard IEC 60590:1977, Determination of the aromatic hydrocarbon content of new mineral insulating oils
    • [16] International Electrotechnical Commission. International Standard IEC 60590:1977, Determination of the aromatic hydrocarbon content of new mineral insulating oils; 1977.
    • (1997)
  • 17
    • 29944439716 scopus 로고    scopus 로고
    • International Electrotechnical Commission
    • International Standard IEC 60666:2010, Detection and determination of specified additives in mineral insulating oils
    • [17] International Electrotechnical Commission. International Standard IEC 60666:2010, Detection and determination of specified additives in mineral insulating oils; 2010.
    • (2010)
  • 18
    • 29944439716 scopus 로고    scopus 로고
    • International Electrotechnical Commission
    • International Standard IEC 60422:2013, Mineral insulating oils in electrical equipment – supervision and maintenance guidance
    • [18] International Electrotechnical Commission. International Standard IEC 60422:2013, Mineral insulating oils in electrical equipment – supervision and maintenance guidance; 2013.
    • (2013)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.