메뉴 건너뛰기




Volumn 7, Issue 2, 1999, Pages 153-163

An efficient implementation of the iterative ML-EM image reconstruction algorithm for PET on a pentium PC platform

Author keywords

Expectation maximization (EM) algorithm; Image reconstruction; Maximum likelihood estimation; PC pentium; Positron emission tomography; Sparse matrix

Indexed keywords

IMAGE PROCESSING; ITERATIVE METHODS; MATRIX ALGEBRA; MAXIMUM ENTROPY METHODS; MAXIMUM LIKELIHOOD; MAXIMUM LIKELIHOOD ESTIMATION; MAXIMUM PRINCIPLE; POSITRON EMISSION TOMOGRAPHY; POSITRONS;

EID: 84974664199     PISSN: 13301136     EISSN: 18463908     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (20)

References (27)
  • 4
    • 85040731537 scopus 로고    scopus 로고
    • Iterative image reconstruction of dynamic PET studies, Acceleration through data compression and distributed processing
    • Stockholm, April
    • H. FRICKE, Iterative image reconstruction of dynamic PET studies, Acceleration through data compression and distributed processing, 1996 EC AT Technical Users' Meeting, Stockholm, April 1996.
    • (1996) 1996 EC AT Technical Users' Meeting
    • Fricke, H.1
  • 5
    • 0024681039 scopus 로고
    • A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs Priors
    • June
    • T. HEBERT AND R. LEAHY, A generalized EM algorithm for 3-D Bayesian reconstruction from Poisson data using Gibbs Priors, IEEE Trans. Med. Imag., 8(2), 194-202, June 1989.
    • (1989) IEEE Trans. Med. Imag. , vol.8 , Issue.2 , pp. 194-202
    • Hebert, T.1    Leahy, R.2
  • 6
    • 0347387783 scopus 로고
    • A parallelized algorithm for image reconstruction from noisy projections
    • T. Coleman and Y. Li, Eds., Philadelphia, SIAM
    • G. HERMAN, D. ODHNER, X. TOENNIES AND S. ZENIOS, A parallelized algorithm for image reconstruction from noisy projections, Proc. Workshop Large Scale Optimization, T. Coleman and Y. Li, Eds., Philadelphia, SIAM, 1990.
    • (1990) Proc. Workshop Large Scale Optimization
    • Herman, G.1    Odhner, D.2    Toennies, X.3    Zenios, S.4
  • 7
    • 0001465863 scopus 로고
    • Positron emission tomographic images and expectation maximization, A VLSI architecture for multiple iterations per second
    • W.F. JONES, L.G. BRYARS AND M.E. CASEY, Positron emission tomographic images and expectation maximization, A VLSI architecture for multiple iterations per second, IEEE Trans. Nucl. Sci., 35, 620-624, 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , pp. 620-624
    • Jones, W.F.1    Bryars, L.G.2    Casey, M.E.3
  • 8
    • 0023314408 scopus 로고
    • Implementing and accelerating the EM algorithm for Positron Emission Tomography
    • March
    • L. KAUFMAN, Implementing and accelerating the EM algorithm for Positron Emission Tomography, IEEE Trans. Med. Imag., 6(1), 37-51, March 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , Issue.1 , pp. 37-51
    • Kaufman, L.1
  • 9
    • 0024143308 scopus 로고
    • JR., AND D. L. SNYDER, A hardware architecture using finite - field arithmetic for computing maximum likelihood estimates in Emission Tomography
    • Dec
    • H. A. KLOTZ, JR., AND D. L. SNYDER, A hardware architecture using finite - field arithmetic for computing maximum likelihood estimates in Emission Tomography, IEEE Trans. Med. Imag., 7(4), Dec. 1988.
    • (1988) IEEE Trans. Med. Imag. , vol.7 , Issue.4
    • Klotz, H.A.1
  • 10
    • 0010260765 scopus 로고    scopus 로고
    • Maximum likelihood image reconstruction in Positron Emission Tomography, Convergence characteristics and stopping rules
    • Rutgers, The State University of New Jersey, New Brunswick, NJ, USA, January
    • G. KONTAXAKIS, Maximum likelihood image reconstruction in Positron Emission Tomography, Convergence characteristics and stopping rules, PhD Dissertation, Rutgers, The State University of New Jersey, New Brunswick, NJ, USA, January 1996.
    • (1996) PhD Dissertation
    • Kontaxakis, G.1
  • 11
    • 0030316358 scopus 로고    scopus 로고
    • A stopping criterion for the EM-MLE image reconstruction for PET
    • Newport Beach, CA, USA, Feb
    • G. KONTAXAKIS AND G.S. TZANAKOS, A stopping criterion for the EM-MLE image reconstruction for PET, Proc. of the SPIE Medical Imaging 1996 Symposium, 2710, 133-144, Newport Beach, CA, USA, Feb. 1996.
    • (1996) Proc. of the SPIE Medical Imaging 1996 Symposium , vol.2710 , pp. 133-144
    • Kontaxakis, G.1    Tzanakos, G.S.2
  • 12
    • 0013402826 scopus 로고    scopus 로고
    • Optimized implementation and performance evaluation of iterative image reconstruction algorithms for PET on distributed Pentium systems and a Web-based interface
    • May
    • G. KONTAXAKIS, L.G. STRAUSS AND G. VAN KAICK, Optimized implementation and performance evaluation of iterative image reconstruction algorithms for PET on distributed Pentium systems and a Web-based interface, J. Nucl. Med., S39, 8P, May 1998.
    • (1998) J. Nucl. Med. , vol.S39 , pp. 8
    • Kontaxakis, G.1    Strauss, L.G.2    Van Kaick, G.3
  • 13
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for Emission and Transmission Tomography
    • K. LANGE AND R. CARSON, EM reconstruction algorithms for Emission and Transmission Tomography, J. Comp. Ass. Tomogr., 8, 302-316, 1984.
    • (1984) J. Comp. Ass. Tomogr. , vol.8 , pp. 302-316
    • Lange, K.1    Carson, R.2
  • 14
    • 0022683404 scopus 로고
    • Accelerated iterative reconstruction for Positron Emission Tomography based on the EM Algorithm for maximum likelihood estimation
    • March
    • R.M. LEWITT AND G. MUEHLLEHNER, Accelerated iterative reconstruction for Positron Emission Tomography based on the EM Algorithm for maximum likelihood estimation, IEEE Trans. Med. Imag., 5(1), 16-22, March 1986.
    • (1986) IEEE Trans. Med. Imag. , vol.5 , Issue.1 , pp. 16-22
    • Lewitt, R.M.1    Muehllehner, G.2
  • 15
    • 9844251860 scopus 로고
    • Towards a practical implementation of the MLE algorithm for Positron Emission Tomography
    • Feb
    • J. LLACER, S. ANDREAE, E. VEKLEROV AND E. J. HOFFMAN, Towards a practical implementation of the MLE algorithm for Positron Emission Tomography, IEEE Trans. Nucl. Sci., 33(1), 468-477, Feb. 1986.
    • (1986) IEEE Trans. Nucl. Sci. , vol.33 , Issue.1 , pp. 468-477
    • Llacer, J.1    Andreae, S.2    Veklerov, E.3    Hoffman, E.J.4
  • 16
    • 0027213289 scopus 로고
    • Results of a clinical receiver operating characteristics study comparing filtered backprojection and maximum likelihood estimator images in FDG PET studies
    • July
    • J. LLACER, E. VEKLEROV, L.R. BAXTER, S.T. GRAFTON, L.K. GRIFFETH, R.A. HAWKINS, C.K. HOH, J.C. MAZZIOTTA, E.J. HOFFMAN AND C.E. METZ, Results of a clinical receiver operating characteristics study comparing filtered backprojection and maximum likelihood estimator images in FDG PET studies, J. Nucl. Med., 34(7), 1198-1203, July 1993.
    • (1993) J. Nucl. Med. , vol.34 , Issue.7 , pp. 1198-1203
    • Llacer, J.1    Veklerov, E.2    Baxter, L.R.3    Grafton, S.T.4    Griffeth, L.K.5    Hawkins, R.A.6    Hoh, C.L.7    Mazziotta, J.C.8    Hoffman, E.J.9    Metz, C.E.10
  • 17
    • 0021375475 scopus 로고
    • Matrix-based image reconstruction methods for tomography
    • Febr
    • J. LLACER AND J.D. MENG, Matrix-based image reconstruction methods for tomography, IEEE Trans. Nucl. Sci., 32(1), 855-864, Febr. 1985.
    • (1985) IEEE Trans. Nucl. Sci. , vol.32 , Issue.1 , pp. 855-864
    • Llacer, J.1    Meng, J.D.2
  • 18
    • 85040715536 scopus 로고
    • Bayesian image reconstruction for Emission Tomography, implementation of the EM algorithm and Good's roughness prior on massively parallel processors
    • March
    • M.I. MILLER, B. ROYSAM AND A.W. MCCARTHY, Bayesian image reconstruction for Emission Tomography, implementation of the EM algorithm and Good's roughness prior on massively parallel processors, Inti. Conf. on Acoustics, Speech and Signal Processing, March 1988.
    • (1988) Inti. Conf. on Acoustics, Speech and Signal Processing
    • Miller, M.I.1    Roysam, B.2    Mccarthy, A.W.3
  • 19
    • 0026669029 scopus 로고
    • Fast maximum-likelihood reconstruction
    • Sept
    • T.R. MILLER AND J.W. WALLIS, Fast maximum-likelihood reconstruction, J. Nucl. Med., 33(9), 1710-1711, Sept. 1992.
    • (1992) J. Nucl. Med. , vol.33 , Issue.9 , pp. 1710-1711
    • Miller, T.R.1    Wallis, J.W.2
  • 20
    • 85040725490 scopus 로고
    • Parallel PET reconstruction by EM iteration with reduced processor communications
    • Univ. of Tennessee, Knoxville, TN, USA, Dec
    • S.P. OLESEN, J. GREGOR AND M.G. THOMASON, Parallel PET reconstruction by EM iteration with reduced processor communications, Technical Report CS-94-256, Univ. of Tennessee, Knoxville, TN, USA, Dec. 1994.
    • (1994) Technical Report CS-94-256
    • Olesen, S.P.1    Gregor, J.2    Thomason, M.G.3
  • 21
    • 0029358349 scopus 로고
    • Linear array implementation of the EM algorithm for PET image reconstruction
    • Aug
    • K. RAJAN, L.M. PATNAIK AND J. RAMAKRISHNA, Linear array implementation of the EM algorithm for PET image reconstruction, IEEE Trans. Nucl. Sci., 42(4), 1439-1444, Aug. 1995.
    • (1995) IEEE Trans. Nucl. Sci. , vol.42 , Issue.4 , pp. 1439-1444
    • Rajan, K.1    Patnaik, L.M.2    Ramakrishna, J.3
  • 22
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction in Positron Emission Tomography
    • L.A. SHEPP AND Y. VARDI, Maximum likelihood reconstruction in Positron Emission Tomography, IEEE Trans. Med. I mag., 1, 113-122, 1982.
    • (1982) IEEE Trans. Med. I mag. , vol.1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 24
    • 0029826105 scopus 로고    scopus 로고
    • Fluorine-18 deoxyglucose and falsepositive results, a major problem in the diagnostics of oncological patients
    • Oct
    • L.G. STRAUSS, Fluorine-18 deoxyglucose and falsepositive results, a major problem in the diagnostics of oncological patients, Eur. J. Nucl. Med., (23) 10, 1409-1415, Oct. 1996.
    • (1996) Eur. J. Nucl. Med. , vol.10 , Issue.23 , pp. 1409-1415
    • Strauss, L.G.1
  • 25
    • 0010293907 scopus 로고
    • A statistical model for Positron Emission Tomography
    • March
    • Y. VARDI, L.A. SHEPP AND L. KAUFMAN, A statistical model for Positron Emission Tomography, J. Amer. Stat. Assoc., 80(389), 8-20, March 1985.
    • (1985) J. Amer. Stat. Assoc. , vol.80 , Issue.389 , pp. 8-20
    • Vardi, Y.1    Shepp, L.A.2    Kaufman, L.3
  • 26
    • 84939061977 scopus 로고
    • MLE reconstruction of a brain phantom using a Monte Carlo probability matrix and a statistical stopping rule
    • Feb
    • E. VEKLEROV, J. LLACER, E. J. HOFFMAN, MLE reconstruction of a brain phantom using a Monte Carlo probability matrix and a statistical stopping rule, IEEE Trans. Nucl. Sci., 35(1), 603-607, Feb. 1988.
    • (1988) IEEE Trans. Nucl. Sci. , vol.35 , Issue.1 , pp. 603-607
    • Veklerov, E.1    Llacer, J.2    Hoffman, E.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.