메뉴 건너뛰기




Volumn 12, Issue 1, 2005, Pages 6-8

USP dissolution calibrators: Re-examination and appraisal

Author keywords

[No Author keywords available]

Indexed keywords

SALICYLIC ACID;

EID: 84974624200     PISSN: 1521298X     EISSN: None     Source Type: Journal    
DOI: 10.14227/DT120105P6     Document Type: Note
Times cited : (10)

References (7)
  • 1
    • 0020085526 scopus 로고
    • Systematic Error Associated with Apparatus 2 of the USP Dissolution Test II: Effects of Deviations in Vessel Curvature from That of a Sphere
    • DC Cox, Wells CE, Furman WB, Savage TS, King AC, Systematic Error Associated with Apparatus 2 of the USP Dissolution Test II: Effects of Deviations in Vessel Curvature from That of a Sphere, J. Pharm Sci, 71(4), 395-399; 1982
    • (1982) J. Pharm Sci , vol.71 , Issue.4 , pp. 395-399
    • Cox, D.C.1    Wells, C.E.2    Furman, W.B.3    Savage, T.S.4    King, A.C.5
  • 2
    • 33845191613 scopus 로고
    • Reproducibility of Dissolution Test Results
    • JF Hamilton, Moore TW, Kerner CM, Reproducibility of Dissolution Test Results, PF 21(5), 1383-1386; 1995
    • (1995) PF , vol.21 , Issue.5 , pp. 1383-1386
    • Hamilton, J.F.1    Moore, T.W.2    Kerner, C.M.3
  • 3
    • 0012499112 scopus 로고
    • Dissolution Testing: Limitations of the USP Prednisone and Salicylic Acid Calibrator Tablets
    • TW Moore, Hamilton JF, Kerner CM, Dissolution Testing: Limitations of the USP Prednisone and Salicylic Acid Calibrator Tablets, PF 21(5), 1387-1396; 1995
    • (1995) PF , vol.21 , Issue.5 , pp. 1387-1396
    • Moore, T.W.1    Hamilton, J.F.2    Kerner, C.M.3
  • 4
    • 0000828169 scopus 로고    scopus 로고
    • Dissolution Calibrator Tablets: A Recommendation for New Calibrator Tablets to Replace Both Current USP Calibrator Tablets
    • TW Moore, Shangraw RF, Habib Y, Dissolution Calibrator Tablets: A Recommendation for New Calibrator Tablets to Replace Both Current USP Calibrator Tablets, PF 22(3), 2423-2428; 1996
    • (1996) PF , vol.22 , Issue.3 , pp. 2423-2428
    • Moore, T.W.1    Shangraw, R.F.2    Habib, Y.3
  • 5
    • 0006896685 scopus 로고    scopus 로고
    • Dissolution Testing: Collaborative Study of the In-house NCDA #2 Dissolution Calibrator Tablets with USP Apparatus 2
    • TW Moore, Cox DC, Dissolution Testing: Collaborative Study of the In-house NCDA #2 Dissolution Calibrator Tablets with USP Apparatus 2, PF 23(3), 4250-4255; 1997
    • (1997) PF , vol.23 , Issue.3 , pp. 4250-4255
    • Moore, T.W.1    Cox, D.C.2
  • 6
    • 0345709077 scopus 로고    scopus 로고
    • Dissolution Calibrator Tablets: A Scaled-up Lot of a New Calibrator Tablet Recommended to Replace Both Current USP Calibrator Tablets
    • TW Moore, Cox DC, Demarest DA, Dissolution Calibrator Tablets: A Scaled-up Lot of a New Calibrator Tablet Recommended to Replace Both Current USP Calibrator Tablets, PF 23(6), 5352-5363; 1997
    • (1997) PF , vol.23 , Issue.6 , pp. 5352-5363
    • Moore, T.W.1    Cox, D.C.2    Demarest, D.A.3
  • 7
    • 0005736590 scopus 로고    scopus 로고
    • Pharmaceutical Research and Manufacturers of America (PhRMA), Dissolution Calibration: Recommendations for Reduced Chemical Testing and Enhanced Mechanical Calibration
    • Subcommittee on Dissolution Calibration, Pharmaceutical Research and Manufacturers of America (PhRMA), Dissolution Calibration: Recommendations for Reduced Chemical Testing and Enhanced Mechanical Calibration, PF 26(4), 1149-1166; 2000
    • (2000) Dissolution Calibration: Recommendations for Reduced Chemical Testing and Enhanced Mechanical Calibration, PF , vol.26 , Issue.4 , pp. 1149-1166


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.