메뉴 건너뛰기




Volumn 36, Issue 7, 2016, Pages 663-670

Bioelectrical impedance is an accurate method to assess body composition in obese but not severely obese adolescents

Author keywords

Bioimpedance; Body composition; DXA; Pediatric obesity

Indexed keywords

ACCURACY; ADOLESCENT; ANALYTIC METHOD; ARM; ARTICLE; BIOIMPEDANCE ANALYSIS; BODY COMPOSITION; BODY COMPOSITION ANALYZER; BODY FAT; BODY WEIGHT; CONTROLLED STUDY; CORRELATION COEFFICIENT; DISEASE SEVERITY; DUAL ENERGY X RAY ABSORPTIOMETRY; FAT FREE MASS; FAT MASS; FEMALE; FRANCE; HUMAN; IMPEDANCE; INTERMETHOD COMPARISON; LEG; MAJOR CLINICAL STUDY; MALE; OBESITY; PRIORITY JOURNAL; REPRODUCIBILITY; SEGMENTAL BODY COMPOSITION; WHOLE BODY COMPOSITION; X RAY SYSTEM; BODY MASS; CHILD; CHILDHOOD OBESITY; COMPARATIVE STUDY; PHOTON ABSORPTIOMETRY;

EID: 84973299015     PISSN: 02715317     EISSN: 18790739     Source Type: Journal    
DOI: 10.1016/j.nutres.2016.04.003     Document Type: Article
Times cited : (66)

References (29)
  • 1
    • 84936805651 scopus 로고    scopus 로고
    • Comparison of anthropometric measurements in children to predict metabolic syndrome in adolescence: analysis of prospective cohort data
    • Wicklow B.A., Becker A., Chateau D., Palmer K., Kozyrskij A., Sellers E.A. Comparison of anthropometric measurements in children to predict metabolic syndrome in adolescence: analysis of prospective cohort data. Int J Obes 2015, 39:1070-1078.
    • (2015) Int J Obes , vol.39 , pp. 1070-1078
    • Wicklow, B.A.1    Becker, A.2    Chateau, D.3    Palmer, K.4    Kozyrskij, A.5    Sellers, E.A.6
  • 3
    • 40649109840 scopus 로고    scopus 로고
    • Gendered dimensions of obesity in childhood and adolescence
    • Sweeting H.N. Gendered dimensions of obesity in childhood and adolescence. Nutr J 2008, 7:1-14.
    • (2008) Nutr J , vol.7 , pp. 1-14
    • Sweeting, H.N.1
  • 6
    • 84927738301 scopus 로고    scopus 로고
    • Comparison of total body and abdominal adiposity indexes to dual x-ray absorptiometry scan in obese adolescents
    • Thivel D., O'Malley G., Pereira B., Duche P., Aucouturier J. Comparison of total body and abdominal adiposity indexes to dual x-ray absorptiometry scan in obese adolescents. Am J Hum Biol 2015, 27:334-338.
    • (2015) Am J Hum Biol , vol.27 , pp. 334-338
    • Thivel, D.1    O'Malley, G.2    Pereira, B.3    Duche, P.4    Aucouturier, J.5
  • 7
    • 0023488498 scopus 로고
    • Methods for the assessment of human body composition: traditional and new
    • Lukaski H.C. Methods for the assessment of human body composition: traditional and new. Am J Clin Nutr 1987, 46:537-556.
    • (1987) Am J Clin Nutr , vol.46 , pp. 537-556
    • Lukaski, H.C.1
  • 9
    • 3242705805 scopus 로고    scopus 로고
    • Validity and reliability of dual-energy X-ray absorptiometry for the assessment of abdominal adiposity
    • Glickman S.G., Marn C.S., Supiano M.A., Dengel D.R. Validity and reliability of dual-energy X-ray absorptiometry for the assessment of abdominal adiposity. J Appl Physiol 2004, 97:509-514.
    • (2004) J Appl Physiol , vol.97 , pp. 509-514
    • Glickman, S.G.1    Marn, C.S.2    Supiano, M.A.3    Dengel, D.R.4
  • 10
    • 84926141818 scopus 로고    scopus 로고
    • Comparison of total and segmental body composition using DXA and multifrequency bioimpedance in collegiate female athletes
    • Esco M.R., Snarr R.L., Leatherwood M.D., Chamberlain N.A., Redding M.L., Flatt A.A., et al. Comparison of total and segmental body composition using DXA and multifrequency bioimpedance in collegiate female athletes. J Strength Cond Res 2015, 29:918-925.
    • (2015) J Strength Cond Res , vol.29 , pp. 918-925
    • Esco, M.R.1    Snarr, R.L.2    Leatherwood, M.D.3    Chamberlain, N.A.4    Redding, M.L.5    Flatt, A.A.6
  • 11
    • 84874024023 scopus 로고    scopus 로고
    • Comparison of two bioelectrical impedance analysis devices with dual energy X-ray absorptiometry and magnetic resonance imaging in the estimation of body composition
    • Wang J.G., Zhang Y., Chen H.E., Li Y., Cheng X.G., Xu L., et al. Comparison of two bioelectrical impedance analysis devices with dual energy X-ray absorptiometry and magnetic resonance imaging in the estimation of body composition. J Strength Cond Res 2013, 27:236-243.
    • (2013) J Strength Cond Res , vol.27 , pp. 236-243
    • Wang, J.G.1    Zhang, Y.2    Chen, H.E.3    Li, Y.4    Cheng, X.G.5    Xu, L.6
  • 12
    • 84945969797 scopus 로고    scopus 로고
    • Comparisons of a multi-frequency bioelectrical impedance analysis to the dual-energy X-ray absorptiometry scan in healthy young adults depending on their physical activity level
    • Verney J., Schwartz C., Amiche S., Pereira B., Thivel D. Comparisons of a multi-frequency bioelectrical impedance analysis to the dual-energy X-ray absorptiometry scan in healthy young adults depending on their physical activity level. J Hum Kinet 2015, 47:73-80.
    • (2015) J Hum Kinet , vol.47 , pp. 73-80
    • Verney, J.1    Schwartz, C.2    Amiche, S.3    Pereira, B.4    Thivel, D.5
  • 13
    • 84922962580 scopus 로고    scopus 로고
    • Comparison of methods for the measurement of body composition in overweight and obese Brazilian children and adolescents before and after a lifestyle modification program
    • Lyra A., Bonfitto A.J., Barbosa V.L., Bezerra A.C., Longui C.A., Monte O., et al. Comparison of methods for the measurement of body composition in overweight and obese Brazilian children and adolescents before and after a lifestyle modification program. Ann Nutr Metab 2015, 66:26-30.
    • (2015) Ann Nutr Metab , vol.66 , pp. 26-30
    • Lyra, A.1    Bonfitto, A.J.2    Barbosa, V.L.3    Bezerra, A.C.4    Longui, C.A.5    Monte, O.6
  • 14
  • 15
    • 84910075407 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis to estimate body composition, and change in adiposity, in overweight and obese adolescents: comparison with dual-energy x-ray absorptiometry
    • Wan C.S., Ward L.C., Halim J., Gow M.L., Ho M., Briody J.N., et al. Bioelectrical impedance analysis to estimate body composition, and change in adiposity, in overweight and obese adolescents: comparison with dual-energy x-ray absorptiometry. BMC Pediatr 2014, 14:249.
    • (2014) BMC Pediatr , vol.14 , pp. 249
    • Wan, C.S.1    Ward, L.C.2    Halim, J.3    Gow, M.L.4    Ho, M.5    Briody, J.N.6
  • 16
    • 0034116222 scopus 로고    scopus 로고
    • Human body composition: in vivo methods
    • Ellis K.J. Human body composition: in vivo methods. Physiol Rev 2000, 80:649-680.
    • (2000) Physiol Rev , vol.80 , pp. 649-680
    • Ellis, K.J.1
  • 17
    • 84926126933 scopus 로고    scopus 로고
    • Agreement of bioelectric impedance analysis and dual-energy X-ray absorptiometry for body composition evaluation in adults with cystic fibrosis
    • Ziai S., Coriati A., Chabot K., Mailhot M., Richter M.V., Rabasa-Lhoret R. Agreement of bioelectric impedance analysis and dual-energy X-ray absorptiometry for body composition evaluation in adults with cystic fibrosis. J Cyst Fibros 2014, 13:585-588.
    • (2014) J Cyst Fibros , vol.13 , pp. 585-588
    • Ziai, S.1    Coriati, A.2    Chabot, K.3    Mailhot, M.4    Richter, M.V.5    Rabasa-Lhoret, R.6
  • 18
    • 0034611996 scopus 로고    scopus 로고
    • Establishing a standard definition for child overweight and obesity worldwide: international survey
    • Cole T.J., Bellizzi M.C., Flegal K.M., Dietz W.H. Establishing a standard definition for child overweight and obesity worldwide: international survey. BMJ 2000, 320:1240-1243.
    • (2000) BMJ , vol.320 , pp. 1240-1243
    • Cole, T.J.1    Bellizzi, M.C.2    Flegal, K.M.3    Dietz, W.H.4
  • 19
    • 0037093925 scopus 로고    scopus 로고
    • Sample size requirements for estimating intraclass correlations with desired precision
    • Bonett D.G. Sample size requirements for estimating intraclass correlations with desired precision. Stat Med 2002, 21:1331-1335.
    • (2002) Stat Med , vol.21 , pp. 1331-1335
    • Bonett, D.G.1
  • 21
    • 17844400838 scopus 로고    scopus 로고
    • Assessing intra, inter and total agreement with replicated readings
    • Barnhart H.X., Song J., Haber M.J. Assessing intra, inter and total agreement with replicated readings. Stat Med 2005, 24:1371-1384.
    • (2005) Stat Med , vol.24 , pp. 1371-1384
    • Barnhart, H.X.1    Song, J.2    Haber, M.J.3
  • 22
    • 0036489067 scopus 로고    scopus 로고
    • Statistical methods in assessing agreement: models, issues & tools
    • Lin L.I., Hedayat A.S., Sinha B., Yang M. Statistical methods in assessing agreement: models, issues & tools. J Am Stat Assoc 2002, 97:257-270.
    • (2002) J Am Stat Assoc , vol.97 , pp. 257-270
    • Lin, L.I.1    Hedayat, A.S.2    Sinha, B.3    Yang, M.4
  • 23
    • 84924054251 scopus 로고    scopus 로고
    • Foot-to-foot bioelectrical impedance accurately tracks direction of adiposity change in overweight and obese 7- to 13-year-old children
    • Kasvis P., Cohen T.R., Loiselle S.E., Kim N., Hazell T.J., Vanstone C.A., et al. Foot-to-foot bioelectrical impedance accurately tracks direction of adiposity change in overweight and obese 7- to 13-year-old children. Nutr Res 2015, 35:206-213.
    • (2015) Nutr Res , vol.35 , pp. 206-213
    • Kasvis, P.1    Cohen, T.R.2    Loiselle, S.E.3    Kim, N.4    Hazell, T.J.5    Vanstone, C.A.6
  • 24
    • 85006391475 scopus 로고    scopus 로고
    • Assessment of body composition by dual-energy X-ray absorptiometry, bioimpedance analysis and anthropometrics in children: the physical activity and nutrition in children study
    • Tompuri T.T., Lakka T.A., Hakulinen M., Lindi V., Laaksonen D.E., Kilpelainen T.O., et al. Assessment of body composition by dual-energy X-ray absorptiometry, bioimpedance analysis and anthropometrics in children: the physical activity and nutrition in children study. Clin Physiol Funct Imaging 2015, 35:21-33.
    • (2015) Clin Physiol Funct Imaging , vol.35 , pp. 21-33
    • Tompuri, T.T.1    Lakka, T.A.2    Hakulinen, M.3    Lindi, V.4    Laaksonen, D.E.5    Kilpelainen, T.O.6
  • 25
    • 84973301586 scopus 로고    scopus 로고
    • Comparison between two methods of bioelectrical impedance analyses for accuracy in measuring abdominal visceral fat area
    • Park K.S., Lee D.H., Lee J., Kim Y.J., Jung K.Y., Kim K.M., et al. Comparison between two methods of bioelectrical impedance analyses for accuracy in measuring abdominal visceral fat area. J Diabetes Complicat 2015.
    • (2015) J Diabetes Complicat
    • Park, K.S.1    Lee, D.H.2    Lee, J.3    Kim, Y.J.4    Jung, K.Y.5    Kim, K.M.6
  • 26
    • 84889085045 scopus 로고    scopus 로고
    • Estimation of abdominal fat mass: validity of abdominal bioelectrical impedance analysis and a new model based on anthropometry compared with dual-energy x-ray absorptiometry
    • Manios Y., Kanellakis S., Moschonis G., Pipidis I., Skoufas E., Zafiropulos V. Estimation of abdominal fat mass: validity of abdominal bioelectrical impedance analysis and a new model based on anthropometry compared with dual-energy x-ray absorptiometry. Menopause 2013, 20:1280-1283.
    • (2013) Menopause , vol.20 , pp. 1280-1283
    • Manios, Y.1    Kanellakis, S.2    Moschonis, G.3    Pipidis, I.4    Skoufas, E.5    Zafiropulos, V.6
  • 27
    • 77957579043 scopus 로고    scopus 로고
    • A new simple method for estimating trunk and visceral fat by bioelectrical impedance: comparison with magnetic resonance imaging and dual X-ray absorptiometry in Czech adolescents
    • Zamrazilova H., Hlavaty P., Dusatkova L., Sedlackova B., Hainerova I.A., Kunesova M., et al. A new simple method for estimating trunk and visceral fat by bioelectrical impedance: comparison with magnetic resonance imaging and dual X-ray absorptiometry in Czech adolescents. Cas Lek Cesk 2010, 149:417-422.
    • (2010) Cas Lek Cesk , vol.149 , pp. 417-422
    • Zamrazilova, H.1    Hlavaty, P.2    Dusatkova, L.3    Sedlackova, B.4    Hainerova, I.A.5    Kunesova, M.6
  • 28
    • 77952040673 scopus 로고    scopus 로고
    • Estimation of abdominal fat compartments by bioelectrical impedance: the validity of the ViScan measurement system in comparison with MRI
    • Thomas E.L., Collins A.L., McCarthy J., Fitzpatrick J., Durighel G., Goldstone A.P., et al. Estimation of abdominal fat compartments by bioelectrical impedance: the validity of the ViScan measurement system in comparison with MRI. Eur J Clin Nutr 2010, 64:525-533.
    • (2010) Eur J Clin Nutr , vol.64 , pp. 525-533
    • Thomas, E.L.1    Collins, A.L.2    McCarthy, J.3    Fitzpatrick, J.4    Durighel, G.5    Goldstone, A.P.6
  • 29
    • 84885854723 scopus 로고    scopus 로고
    • Bioelectrical impedance analysis to estimate body composition in children and adolescents: a systematic review and evidence appraisal of validity, responsiveness, reliability and measurement error
    • Talma H., Chinapaw M.J., Bakker B., HiraSing R.A., Terwee C.B., Altenburg T.M. Bioelectrical impedance analysis to estimate body composition in children and adolescents: a systematic review and evidence appraisal of validity, responsiveness, reliability and measurement error. Obes Rev 2013, 14:895-905.
    • (2013) Obes Rev , vol.14 , pp. 895-905
    • Talma, H.1    Chinapaw, M.J.2    Bakker, B.3    HiraSing, R.A.4    Terwee, C.B.5    Altenburg, T.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.