메뉴 건너뛰기




Volumn 125, Issue , 2016, Pages 276-286

Efficacy of greenhouse natural ventilation: Environmental monitoring and CFD simulations of a study case

Author keywords

Airflow; CFD simulation; Cooling; Greenhouse

Indexed keywords

COOLING; FINITE ELEMENT METHOD; GREENHOUSES; NUMERICAL MODELS; ROOFS; VENTILATION; VENTS;

EID: 84970956287     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2016.05.014     Document Type: Article
Times cited : (124)

References (32)
  • 1
    • 33646495553 scopus 로고    scopus 로고
    • Effect of vent openings and insect screens on greenhouse ventilation
    • N. Katsoulas, T. Bartzanas, T. Boulard, M. Mermier, and C. Kittas Effect of vent openings and insect screens on greenhouse ventilation Biosyst. Eng. 93 2006 427 436 10.1016/j.biosystemseng.2005.01.001
    • (2006) Biosyst. Eng. , vol.93 , pp. 427-436
    • Katsoulas, N.1    Bartzanas, T.2    Boulard, T.3    Mermier, M.4    Kittas, C.5
  • 4
    • 72149103794 scopus 로고    scopus 로고
    • Dynamic modeling and simulation of greenhouse environments under several scenarios: A web-based application
    • E. Fitz-Rodríguez, C. Kubota, G.A. Giacomelli, M.E. Tignor, S.B. Wilson, and M. McMahon Dynamic modeling and simulation of greenhouse environments under several scenarios: a web-based application Comput. Electron. Agric. 70 2010 105 116 10.1016/j.compag.2009.09.010
    • (2010) Comput. Electron. Agric. , vol.70 , pp. 105-116
    • Fitz-Rodríguez, E.1    Kubota, C.2    Giacomelli, G.A.3    Tignor, M.E.4    Wilson, S.B.5    McMahon, M.6
  • 5
    • 71749111279 scopus 로고    scopus 로고
    • Design and technology for greenhouse cooling in tropical and subtropical regions: A review
    • K.S. Kumar, K.N. Tiwari, and M.K. Jha Design and technology for greenhouse cooling in tropical and subtropical regions: a review Energy Build. 41 2009 1269 1275 10.1016/j.enbuild.2009.08.003
    • (2009) Energy Build. , vol.41 , pp. 1269-1275
    • Kumar, K.S.1    Tiwari, K.N.2    Jha, M.K.3
  • 6
    • 77951096942 scopus 로고    scopus 로고
    • Modeling and evaluation of greenhouse for floriculture in subtropics
    • K.S. Kumar, M.K. Jha, K.N. Tiwari, and A. Singh Modeling and evaluation of greenhouse for floriculture in subtropics Energy Build. 42 2010 1075 1083 10.1016/j.enbuild.2010.01.021
    • (2010) Energy Build. , vol.42 , pp. 1075-1083
    • Kumar, K.S.1    Jha, M.K.2    Tiwari, K.N.3    Singh, A.4
  • 7
    • 69749114965 scopus 로고    scopus 로고
    • A study of natural ventilation in an Almería-type greenhouse with insect screens by means of tri-sonic anemometry
    • F.D. Molina-Aiz, D.L. Valera, A.A. Peña, J.A. Gil, and A. López A study of natural ventilation in an Almería-type greenhouse with insect screens by means of tri-sonic anemometry Biosyst. Eng. 104 2009 224 242 10.1016/j.biosystemseng.2009.06.013
    • (2009) Biosyst. Eng. , vol.104 , pp. 224-242
    • Molina-Aiz, F.D.1    Valera, D.L.2    Peña, A.A.3    Gil, J.A.4    López, A.5
  • 8
    • 3342920188 scopus 로고    scopus 로고
    • Effect of vent arrangement on windward ventilation of a tunnel greenhouse
    • T. Bartzanas, T. Boulard, and C. Kittas Effect of vent arrangement on windward ventilation of a tunnel greenhouse Biosyst. Eng. 88 2004 479 490 10.1016/j.biosystemseng.2003.10.006
    • (2004) Biosyst. Eng. , vol.88 , pp. 479-490
    • Bartzanas, T.1    Boulard, T.2    Kittas, C.3
  • 9
    • 62649174081 scopus 로고    scopus 로고
    • Model development and experimental validation of a floriculture greenhouse under natural ventilation
    • A. Ganguly, and S. Ghosh Model development and experimental validation of a floriculture greenhouse under natural ventilation Energy Build. 41 2009 521 527 10.1016/j.enbuild.2008.11.021
    • (2009) Energy Build. , vol.41 , pp. 521-527
    • Ganguly, A.1    Ghosh, S.2
  • 10
  • 13
    • 58149241071 scopus 로고    scopus 로고
    • The impact of insect screens and ventilation openings on the greenhouse microclimate
    • C. Kittas, N. Katsoulas, T. Bartzanas, M. Mermier, and T. Boulard The impact of insect screens and ventilation openings on the greenhouse microclimate Trans. ASABE 51 2008 2151 2165
    • (2008) Trans. ASABE , vol.51 , pp. 2151-2165
    • Kittas, C.1    Katsoulas, N.2    Bartzanas, T.3    Mermier, M.4    Boulard, T.5
  • 14
    • 77954861067 scopus 로고    scopus 로고
    • Comparison of finite element and finite volume methods for simulation of natural ventilation in greenhouses
    • F.D. Molina-Aiz, H. Fatnassi, T. Boulard, J.C. Roy, and D.L. Valera Comparison of finite element and finite volume methods for simulation of natural ventilation in greenhouses Comput. Electron. Agric. 72 2010 69 86 10.1016/j.compag.2010.03.002
    • (2010) Comput. Electron. Agric. , vol.72 , pp. 69-86
    • Molina-Aiz, F.D.1    Fatnassi, H.2    Boulard, T.3    Roy, J.C.4    Valera, D.L.5
  • 15
    • 84928347146 scopus 로고    scopus 로고
    • Present and future of the numerical methods in buildings and infrastructures areas of biosystems engineering
    • F. Ayuga Present and future of the numerical methods in buildings and infrastructures areas of biosystems engineering J. Agric. Eng. 46 2015 1 10.4081/jae.2015.436
    • (2015) J. Agric. Eng. , vol.46 , pp. 1
    • Ayuga, F.1
  • 16
    • 50049122667 scopus 로고    scopus 로고
    • Wind driven ventilation of a mono-span greenhouse with a rose crop and continuous screened side vents and its effect on flow patterns and microclimate
    • M. Teitel, O. Liran, J. Tanny, and M. Barak Wind driven ventilation of a mono-span greenhouse with a rose crop and continuous screened side vents and its effect on flow patterns and microclimate Biosyst. Eng. 101 2008 111 122 10.1016/j.biosystemseng.2008.05.012
    • (2008) Biosyst. Eng. , vol.101 , pp. 111-122
    • Teitel, M.1    Liran, O.2    Tanny, J.3    Barak, M.4
  • 18
    • 84894426590 scopus 로고    scopus 로고
    • Air exchange and ventilation efficiencies of a monospan greenhouse with one inflow and one outflow through longitudinal side openings
    • M. Teitel, and E. Wenger Air exchange and ventilation efficiencies of a monospan greenhouse with one inflow and one outflow through longitudinal side openings Biosyst. Eng. 119 2014 98 107 10.1016/j.biosystemseng.2013.11.001
    • (2014) Biosyst. Eng. , vol.119 , pp. 98-107
    • Teitel, M.1    Wenger, E.2
  • 19
    • 84875855332 scopus 로고    scopus 로고
    • The past, present and future of CFD for agro-environmental applications, Comput
    • I.-B. Lee, J.P.P. Bitog, S.-W. Hong, I.-H. Seo, K.-S. Kwon, T. Bartzanas, and et al. The past, present and future of CFD for agro-environmental applications, Comput Electron. Agric. 93 2013 168 183 10.1016/j.compag.2012.09.006
    • (2013) Electron. Agric. , vol.93 , pp. 168-183
    • Lee, I.-B.1    Bitog, J.P.P.2    Hong, S.-W.3    Seo, I.-H.4    Kwon, K.-S.5    Bartzanas, T.6
  • 20
    • 77349098779 scopus 로고    scopus 로고
    • Numerical simulation of thermal behavior of a ventilated arc greenhouse during a solar day
    • D.K. Fidaros, C.A. Baxevanou, T. Bartzanas, and C. Kittas Numerical simulation of thermal behavior of a ventilated arc greenhouse during a solar day Renew. Energy 35 2010 1380 1386 10.1016/j.renene.2009.11.013
    • (2010) Renew. Energy , vol.35 , pp. 1380-1386
    • Fidaros, D.K.1    Baxevanou, C.A.2    Bartzanas, T.3    Kittas, C.4
  • 21
    • 84970943468 scopus 로고    scopus 로고
    • http://www.climatedata.eu/climate.php?loc=itxx0006&lang=en, (2016).
    • (2016)
  • 22
    • 84879717874 scopus 로고    scopus 로고
    • Numerical simulation of solar radiation, air flow and temperature distribution in a naturally ventilated tunnel greenhouse
    • C. Baxevanou, D. Fidaros, T. Bartzanas, and C. Kittas Numerical simulation of solar radiation, air flow and temperature distribution in a naturally ventilated tunnel greenhouse Agric. Eng. Int. CIGR J. 12 2010 48 67
    • (2010) Agric. Eng. Int. CIGR J. , vol.12 , pp. 48-67
    • Baxevanou, C.1    Fidaros, D.2    Bartzanas, T.3    Kittas, C.4
  • 23
    • 0022793493 scopus 로고
    • An equal-order velocity-pressure formulation that does not exhibit spurious pressure modes
    • J.G. Rice, and R.J. Schnipke An equal-order velocity-pressure formulation that does not exhibit spurious pressure modes Comput. Methods Appl. Mech. Eng. 58 1986 135 149 10.1016/0045-7825(86)90093-9
    • (1986) Comput. Methods Appl. Mech. Eng. , vol.58 , pp. 135-149
    • Rice, J.G.1    Schnipke, R.J.2
  • 24
    • 0023148235 scopus 로고
    • Finite element method for free and forced convection heat transfer
    • R.J. Schnipke, and J.G. Rice Finite element method for free and forced convection heat transfer Int. J. Numer. Methods Eng. 24 1987 117 128
    • (1987) Int. J. Numer. Methods Eng. , vol.24 , pp. 117-128
    • Schnipke, R.J.1    Rice, J.G.2
  • 26
    • 78650223332 scopus 로고    scopus 로고
    • A parameter robust Petrov-Galerkin scheme for advection-diffusion-reaction equations
    • C. de Falco, and E. O'Riordan A parameter robust Petrov-Galerkin scheme for advection-diffusion-reaction equations Numer. Algorithms 56 2010 107 127 10.1007/s11075-010-9376-y
    • (2010) Numer. Algorithms , vol.56 , pp. 107-127
    • De Falco, C.1    O'Riordan, E.2
  • 27
    • 84930613150 scopus 로고    scopus 로고
    • Aerodynamic study of greenhouses using computational fluid dynamics
    • E. Rico-García Aerodynamic study of greenhouses using computational fluid dynamics Int. J. Phys. Sci. 6 2011 10.5897/ijps11.852
    • (2011) Int. J. Phys. Sci. , vol.6
    • Rico-García, E.1
  • 29
    • 36048980030 scopus 로고    scopus 로고
    • Simulations of pollutant dispersion within idealised urban-type geometries with CFD and integral models
    • S. Di Sabatino, R. Buccolieri, B. Pulvirenti, and R. Britter Simulations of pollutant dispersion within idealised urban-type geometries with CFD and integral models Atmos. Environ. 41 2007 8316 8329 10.1016/j.atmosenv.2007.06.052
    • (2007) Atmos. Environ. , vol.41 , pp. 8316-8329
    • Di Sabatino, S.1    Buccolieri, R.2    Pulvirenti, B.3    Britter, R.4
  • 30
    • 33846850076 scopus 로고    scopus 로고
    • Multivariate calibration of hyperspectral-ray energy spectra for proximal soil sensing
    • R.A.V. Rossel, H.J. Taylor, and A.B. McBratney Multivariate calibration of hyperspectral-ray energy spectra for proximal soil sensing Eur. J. Soil Sci. 58 2007 343 353 10.1111/j. 1365-2389.2006.00859.x
    • (2007) Eur. J. Soil Sci. , vol.58 , pp. 343-353
    • Rossel, R.A.V.1    Taylor, H.J.2    McBratney, A.B.3
  • 31
    • 84892960976 scopus 로고    scopus 로고
    • Current status and future advances for wind speed and power forecasting
    • J. Jung, and R.P. Broadwater Current status and future advances for wind speed and power forecasting Renew. Sustain. Energy Rev. 31 2014 762 777 10.1016/j.rser.2013.12.054
    • (2014) Renew. Sustain. Energy Rev. , vol.31 , pp. 762-777
    • Jung, J.1    Broadwater, R.P.2
  • 32
    • 84970982266 scopus 로고    scopus 로고
    • A simple weather forecasting model using mathematical regression, indian res
    • P. Mathur, and S. Mathur A simple weather forecasting model using mathematical regression, indian res Indian Res. J. Ext. Educ. 12 2012 161 168
    • (2012) Indian Res. J. Ext. Educ. , vol.12 , pp. 161-168
    • Mathur, P.1    Mathur, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.