메뉴 건너뛰기




Volumn , Issue , 2015, Pages

Monitoring of power transformer bushings in high voltage substations

Author keywords

bushing; maintanence; monitoring; power system; power transformer

Indexed keywords

CAPACITANCE; ELECTRIC POWER SYSTEM MEASUREMENT; MONITORING; NETWORK MANAGEMENT; POWER TRANSFORMERS; TRANSFORMER WINDINGS;

EID: 84964598951     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/AMPS.2015.7312741     Document Type: Conference Paper
Times cited : (12)

References (16)
  • 4
    • 0033724112 scopus 로고    scopus 로고
    • On-line diagnostics of high-voltage bushings and current transformers using the sum current method
    • Jan
    • M.F. Lachman, W. Walter, P.A. von Guggenberg, "On-line diagnostics of high-voltage bushings and current transformers using the sum current method," IEEE Trans. on Power Del., vol. 15, no. 1, pp.155-162, Jan. 2000
    • (2000) IEEE Trans. on Power Del , vol.15 , Issue.1 , pp. 155-162
    • Lachman, M.F.1    Walter, W.2    Von Guggenberg, P.A.3
  • 9
    • 33745634614 scopus 로고    scopus 로고
    • Frequency response of oil impregnated press board and paper samples for estimating moisture in transformer insulation
    • C. Ekanavake, S. M. Gubanski, A. Graczkowski, K. Walczak, "Frequency response of oil impregnated press board and paper samples for estimating moisture in transformer insulation", IEEE Trans. Power Del., vol. 2, pp. 1309-1317, 2006
    • (2006) IEEE Trans. Power Del , vol.2 , pp. 1309-1317
    • Ekanavake, C.1    Gubanski, S.M.2    Graczkowski, A.3    Walczak, K.4
  • 11
    • 77956992185 scopus 로고    scopus 로고
    • Lightning-induced overvoltages transmitted over distribution transformer with MV spark-gap operation-part 1: High-frequency transformer model
    • N. A. Sabiha, M. Lehtonen, "Lightning-induced overvoltages transmitted over distribution transformer with MV spark-gap operation-part 1: high-frequency transformer model", IEEE Trans. Power Del., vol. 25, pp. 2472-2480, 2010
    • (2010) IEEE Trans. Power Del , vol.25 , pp. 2472-2480
    • Sabiha, N.A.1    Lehtonen, M.2
  • 12
    • 84863063203 scopus 로고    scopus 로고
    • High-frequency model of metal-oxide surge arrester for researching on VFTO
    • L. Xin, W. Jing, X. Jianyuan, "High-frequency model of metal-oxide surge arrester for researching on VFTO", 1st Int. Conf. on Switching Technology, pp. 577-581, 2011
    • (2011) 1st Int. Conf. on Switching Technology , pp. 577-581
    • Xin, L.1    Jing, W.2    Jianyuan, X.3
  • 15
    • 84870008951 scopus 로고    scopus 로고
    • Approaches for suppressing of lightning overvoltage in the gas-insulated substation (GIS)
    • A. Tavakoli, A.Gholami, A.Parizad, "Approaches for suppressing of lightning overvoltage in the gas-insulated substation (GIS)", Asia-Pacific Power and Energy Eng. Conf., pp. 1-5, 2010
    • (2010) Asia-Pacific Power and Energy Eng. Conf , pp. 1-5
    • Tavakoli, A.1    Gholami, A.2    Parizad, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.