메뉴 건너뛰기




Volumn 27, Issue 1, 2017, Pages 138-148

Complication rates of CT-guided transthoracic lung biopsy: meta-analysis

Author keywords

Biopsy; Computed tomography, X Ray; Lung neoplasms; Meta analysis; Pneumothorax

Indexed keywords

ARTICLE; BIOPSY NEEDLE; COMPUTER ASSISTED TOMOGRAPHY; FINE NEEDLE ASPIRATION BIOPSY; HEMATOTHORAX; HEMOPTYSIS; HUMAN; LUNG COMPLICATION; LUNG HEMORRHAGE; LUNG PARENCHYMA; META ANALYSIS; PRIORITY JOURNAL; RISK FACTOR; TRANSTHORACIC BIOPSY; ADVERSE EFFECTS; DIAGNOSTIC IMAGING; HEALTH; IMAGE GUIDED BIOPSY; INCIDENCE; LARGE CORE NEEDLE BIOPSY; LUNG; LUNG NEOPLASMS; PNEUMOTHORAX; PROCEDURES; RETROSPECTIVE STUDY; X-RAY COMPUTED TOMOGRAPHY;

EID: 84964211727     PISSN: 09387994     EISSN: 14321084     Source Type: Journal    
DOI: 10.1007/s00330-016-4357-8     Document Type: Article
Times cited : (489)

References (75)
  • 1
    • 84895811460 scopus 로고    scopus 로고
    • Screening for lung cancer: U.S. Preventive services task force recommendation statement
    • PID: 24378917
    • Moyer VA (2014) Screening for lung cancer: U.S. Preventive services task force recommendation statement. Ann Intern Med 160:330–8
    • (2014) Ann Intern Med , vol.160 , pp. 330-338
    • Moyer, V.A.1
  • 2
    • 84937468353 scopus 로고    scopus 로고
    • ESR/ERS white paper on lung cancer screening
    • PID: 25929956
    • Kauczor H-U, Bonomo L, Gaga M et al (2015) ESR/ERS white paper on lung cancer screening. Eur Respir J 46:28–39
    • (2015) Eur Respir J , vol.46 , pp. 28-39
    • Kauczor, H.-U.1    Bonomo, L.2    Gaga, M.3
  • 3
    • 0030280623 scopus 로고    scopus 로고
    • Quality improvement guidelines for image-guided percutaneous biopsy in adults: society of cardiovascular & interventional radiology standards of practice committee
    • COI: 1:STN:280:DyaK2s7gvFCrtw%3D%3D, PID: 8951765
    • Cardella JF, Bakal CW, Bertino RE et al (1996) Quality improvement guidelines for image-guided percutaneous biopsy in adults: society of cardiovascular & interventional radiology standards of practice committee. J Vasc Interv Radiol 7:943–6
    • (1996) J Vasc Interv Radiol , vol.7 , pp. 943-946
    • Cardella, J.F.1    Bakal, C.W.2    Bertino, R.E.3
  • 4
    • 0242693998 scopus 로고    scopus 로고
    • Guidelines for radiologically guided lung biopsy
    • COI: 1:STN:280:DC%2BD3srhtVWruw%3D%3D, PID: 14586042
    • Manhire A, Charig M, Clelland C et al (2003) Guidelines for radiologically guided lung biopsy. Thorax 58:920–36
    • (2003) Thorax , vol.58 , pp. 920-936
    • Manhire, A.1    Charig, M.2    Clelland, C.3
  • 5
    • 84858197268 scopus 로고    scopus 로고
    • Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy
    • PID: 22933975
    • Beslic S, Zukic F, Milisic S (2012) Percutaneous transthoracic CT guided biopsies of lung lesions; fine needle aspiration biopsy versus core biopsy. Radiol Oncol 46:19–22
    • (2012) Radiol Oncol , vol.46 , pp. 19-22
    • Beslic, S.1    Zukic, F.2    Milisic, S.3
  • 6
    • 0038476397 scopus 로고    scopus 로고
    • Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures
    • PID: 12761311
    • Yeow KM, Tsay PK, Cheung YC, Lui KW, Pan KT, Chou AS (2003) Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures. J Vasc Interv Radiol 14:581–8
    • (2003) J Vasc Interv Radiol , vol.14 , pp. 581-588
    • Yeow, K.M.1    Tsay, P.K.2    Cheung, Y.C.3    Lui, K.W.4    Pan, K.T.5    Chou, A.S.6
  • 7
    • 0033805578 scopus 로고    scopus 로고
    • Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique
    • COI: 1:STN:280:DC%2BD3M%2FisVWmsQ%3D%3D, PID: 10960539
    • Laurent F, Latrabe V, Vergier B, Michel P (2000) Percutaneous CT-guided biopsy of the lung: comparison between aspiration and automated cutting needles using a coaxial technique. Cardiovasc Intervent Radiol 23:266–72
    • (2000) Cardiovasc Intervent Radiol , vol.23 , pp. 266-272
    • Laurent, F.1    Latrabe, V.2    Vergier, B.3    Michel, P.4
  • 8
    • 84900450744 scopus 로고    scopus 로고
    • Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease
    • Tuna T, Ozkaya S, Dirican A, Findik S, Atici AG, Erkan L (2013) Diagnostic efficacy of computed tomography-guided transthoracic needle aspiration and biopsy in patients with pulmonary disease. Oncol Targets Ther 6:1553–7
    • (2013) Oncol Targets Ther , vol.6 , pp. 1553-1557
    • Tuna, T.1    Ozkaya, S.2    Dirican, A.3    Findik, S.4    Atici, A.G.5    Erkan, L.6
  • 9
    • 84856927551 scopus 로고    scopus 로고
    • Fine-needle aspiration biopsy versus core-needle biopsy in diagnosing lung cancer: a systematic review
    • COI: 1:STN:280:DC%2BC383is1ahuw%3D%3D, PID: 22328844
    • Yao X, Gomes MM, Tsao MS, Allen CJ, Geddie W, Sekhon H (2012) Fine-needle aspiration biopsy versus core-needle biopsy in diagnosing lung cancer: a systematic review. Curr Oncol 19:e16–27
    • (2012) Curr Oncol , vol.19 , pp. e16-e27
    • Yao, X.1    Gomes, M.M.2    Tsao, M.S.3    Allen, C.J.4    Geddie, W.5    Sekhon, H.6
  • 10
    • 68049122102 scopus 로고    scopus 로고
    • Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement
    • PID: 19621072
    • Moher D, Liberati A, Tetzlaff J, Altman DG (2009) Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med 6:e1000097
    • (2009) PLoS Med , vol.6
    • Moher, D.1    Liberati, A.2    Tetzlaff, J.3    Altman, D.G.4
  • 12
    • 3242877827 scopus 로고    scopus 로고
    • Society of interventional radiology clinical practice guidelines
    • PID: 14514818
    • Sacks D, McClenny TE, Cardella JF, Lewis CA (2003) Society of interventional radiology clinical practice guidelines. J Vasc Interv Radiol 14:S199–202
    • (2003) J Vasc Interv Radiol , vol.14 , pp. S199-S202
    • Sacks, D.1    McClenny, T.E.2    Cardella, J.F.3    Lewis, C.A.4
  • 14
    • 79952279847 scopus 로고    scopus 로고
    • The results of computed tomography guided tru-cut transthoracic biopsy: complications and related risk factors
    • PID: 21327675
    • Besir FH, Altin R, Kart L et al (2011) The results of computed tomography guided tru-cut transthoracic biopsy: complications and related risk factors. Wien Klin Wochenschr 123:79–82
    • (2011) Wien Klin Wochenschr , vol.123 , pp. 79-82
    • Besir, F.H.1    Altin, R.2    Kart, L.3
  • 15
    • 43449111487 scopus 로고    scopus 로고
    • CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track
    • PID: 18270713
    • Billich C, Muche R, Brenner G et al (2008) CT-guided lung biopsy: incidence of pneumothorax after instillation of NaCl into the biopsy track. Eur Radiol 18:1146–52
    • (2008) Eur Radiol , vol.18 , pp. 1146-1152
    • Billich, C.1    Muche, R.2    Brenner, G.3
  • 16
    • 77954357074 scopus 로고    scopus 로고
    • Transthoracic lung and mediastinal biopsies obtained with the Tru-Cut technique: 10 years’ experience
    • Bozbas SS, Akcay S, Ergur FO, Aytekin C, Savas BS, Ozturk EF (2010) Transthoracic lung and mediastinal biopsies obtained with the Tru-Cut technique: 10 years’ experience. Turkish J Med Sci 40:495–501
    • (2010) Turkish J Med Sci , vol.40 , pp. 495-501
    • Bozbas, S.S.1    Akcay, S.2    Ergur, F.O.3    Aytekin, C.4    Savas, B.S.5    Ozturk, E.F.6
  • 17
    • 84878115250 scopus 로고    scopus 로고
    • Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy
    • PID: 22146973
    • Braak SJ, Herder GJ, van Heesewijk JP, van Strijen MJ (2012) Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy. Cardiovasc Intervent Radiol 35:1414–21
    • (2012) Cardiovasc Intervent Radiol , vol.35 , pp. 1414-1421
    • Braak, S.J.1    Herder, G.J.2    van Heesewijk, J.P.3    van Strijen, M.J.4
  • 18
    • 84902460820 scopus 로고    scopus 로고
    • Computer tomography-guided core biopsies in a county hospital in Sweden: Complication rate and diagnostic yield
    • PID: 24987473
    • Brandén E, Wallgren S, Högberg H, Koyi H (2014) Computer tomography-guided core biopsies in a county hospital in Sweden: Complication rate and diagnostic yield. Ann Thorac Med 9:149–53
    • (2014) Ann Thorac Med , vol.9 , pp. 149-153
    • Brandén, E.1    Wallgren, S.2    Högberg, H.3    Koyi, H.4
  • 19
    • 59349092350 scopus 로고    scopus 로고
    • Risk assessment of pneumothorax and pulmonary haemorrhage complicating percutaneous co-axial cutting needle lung biopsy
    • PID: 18977128
    • Chakrabarti B, Earis JE, Pandey R et al (2009) Risk assessment of pneumothorax and pulmonary haemorrhage complicating percutaneous co-axial cutting needle lung biopsy. Respir Med 103:449–55
    • (2009) Respir Med , vol.103 , pp. 449-455
    • Chakrabarti, B.1    Earis, J.E.2    Pandey, R.3
  • 20
    • 84905243303 scopus 로고    scopus 로고
    • Risk factors of pneumothorax after CT-guided coaxial cutting needle lung biopsy through aerated versus nonaerated lung
    • PID: 24854390
    • Lim C-S, Tan L-E, Wang J-Y et al (2014) Risk factors of pneumothorax after CT-guided coaxial cutting needle lung biopsy through aerated versus nonaerated lung. J Vasc Interv Radiol 25:1209–17
    • (2014) J Vasc Interv Radiol , vol.25 , pp. 1209-1217
    • Lim, C.-S.1    Tan, L.-E.2    Wang, J.-Y.3
  • 21
    • 0035277521 scopus 로고    scopus 로고
    • CT-guided percutaneous core biopsies of pulmonary lesions. Diagnostic accuracy, complications and therapeutic impact
    • Hanninen EL, Vogl TJ, Ricke J, Felix R, Lopez Hanninen E (2001) CT-guided percutaneous core biopsies of pulmonary lesions. Diagnostic accuracy, complications and therapeutic impact. Acta Radiol 42:151–5
    • (2001) Acta Radiol , vol.42 , pp. 151-155
    • Hanninen, E.L.1    Vogl, T.J.2    Ricke, J.3    Felix, R.4    Lopez Hanninen, E.5
  • 22
    • 33744804307 scopus 로고    scopus 로고
    • Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses
    • PID: 16541227
    • Heck SL, Blom P, Berstad A (2006) Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses. Eur Radiol 16:1387–92
    • (2006) Eur Radiol , vol.16 , pp. 1387-1392
    • Heck, S.L.1    Blom, P.2    Berstad, A.3
  • 23
    • 77749298656 scopus 로고    scopus 로고
    • Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period
    • PID: 20173164
    • Hiraki T, Mimura H, Gobara H et al (2010) Incidence of and risk factors for pneumothorax and chest tube placement after CT fluoroscopy-guided percutaneous lung biopsy: retrospective analysis of the procedures conducted over a 9-year period. AJR Am J Roentgenol 194:809–14
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 809-814
    • Hiraki, T.1    Mimura, H.2    Gobara, H.3
  • 24
    • 45849132404 scopus 로고    scopus 로고
    • Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy
    • COI: 1:STN:280:DC%2BD1czovFSksA%3D%3D, PID: 18351356
    • Khan MF, Straub R, Moghaddam SR et al (2008) Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol 18:1356–63
    • (2008) Eur Radiol , vol.18 , pp. 1356-1363
    • Khan, M.F.1    Straub, R.2    Moghaddam, S.R.3
  • 25
    • 37549057389 scopus 로고    scopus 로고
    • Diagnostic accuracy of CT-guided core biopsy of ground-glass opacity pulmonary lesions
    • PID: 18094317
    • Kim TJ, Lee JH-H, Lee CT-T et al (2008) Diagnostic accuracy of CT-guided core biopsy of ground-glass opacity pulmonary lesions. AJR Am J Roentgenol 190:234–9
    • (2008) AJR Am J Roentgenol , vol.190 , pp. 234-239
    • Kim, T.J.1    Lee, J.H.-H.2    Lee, C.T.-T.3
  • 26
    • 33748995913 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy using a puncture site-down positioning technique
    • PID: 16985136
    • Kinoshita F, Kato T, Sugiura K et al (2006) CT-guided transthoracic needle biopsy using a puncture site-down positioning technique. AJR Am J Roentgenol 187:926–32
    • (2006) AJR Am J Roentgenol , vol.187 , pp. 926-932
    • Kinoshita, F.1    Kato, T.2    Sugiura, K.3
  • 27
    • 0034523283 scopus 로고    scopus 로고
    • CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle
    • COI: 1:STN:280:DC%2BD3c3ktF2jtQ%3D%3D, PID: 10767187
    • Laurent F, Latrabe V, Vergier B, Montaudon M, Vernejoux JM, Dubrez J (2000) CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle. Clin Radiol 55:281–7
    • (2000) Clin Radiol , vol.55 , pp. 281-287
    • Laurent, F.1    Latrabe, V.2    Vergier, B.3    Montaudon, M.4    Vernejoux, J.M.5    Dubrez, J.6
  • 28
    • 33644835374 scopus 로고    scopus 로고
    • Percutaneous CT-guided multisampling core needle biopsy of thoracic lesions
    • Loubeyre P, Copercini M, Dietrich PY (2005) Percutaneous CT-guided multisampling core needle biopsy of thoracic lesions. Am J Roentgenol 185:1294–8
    • (2005) Am J Roentgenol , vol.185 , pp. 1294-1298
    • Loubeyre, P.1    Copercini, M.2    Dietrich, P.Y.3
  • 29
    • 84863594725 scopus 로고    scopus 로고
    • Diagnostic accuracy of CT readings on coin lesions in the lung as compared with transthoracic CT-guided needle biopsy results
    • COI: 1:STN:280:DC%2BC38jovFOktw%3D%3D, PID: 22782457
    • Maataoui A, Vogl TJ, Jacobi V, Khan MF (2012) Diagnostic accuracy of CT readings on coin lesions in the lung as compared with transthoracic CT-guided needle biopsy results. Pneumologie 66:432–6
    • (2012) Pneumologie , vol.66 , pp. 432-436
    • Maataoui, A.1    Vogl, T.J.2    Jacobi, V.3    Khan, M.F.4
  • 30
    • 84895167880 scopus 로고    scopus 로고
    • CT-guided core biopsy and percutaneous fiducial seed placement in the lung: can these procedures be combined without an increase in complication rate or decrease in technical success?
    • Mendiratta-Lala M, Sheiman R, Brook OR, Gourtsoyianni S, Mahadevan A, Siewert B (2014) CT-guided core biopsy and percutaneous fiducial seed placement in the lung: can these procedures be combined without an increase in complication rate or decrease in technical success? Eur J Radiol
    • (2014) Eur J Radiol
    • Mendiratta-Lala, M.1    Sheiman, R.2    Brook, O.R.3    Gourtsoyianni, S.4    Mahadevan, A.5    Siewert, B.6
  • 31
    • 3242763913 scopus 로고    scopus 로고
    • Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions
    • PID: 14963689
    • Montaudon M, Latrabe V, Pariente A, Corneloup O, Begueret H, Laurent F (2004) Factors influencing accuracy of CT-guided percutaneous biopsies of pulmonary lesions. Eur Radiol 14:1234–40
    • (2004) Eur Radiol , vol.14 , pp. 1234-1240
    • Montaudon, M.1    Latrabe, V.2    Pariente, A.3    Corneloup, O.4    Begueret, H.5    Laurent, F.6
  • 32
    • 84918529987 scopus 로고    scopus 로고
    • Computed tomography-guided percutaneous lung biopsy: impact of lesion proximity to diaphragm on biopsy yield and pneumothorax rate
    • PID: 25314026
    • Patel MV, Ahmed O, Jilani D, Zangan S (2014) Computed tomography-guided percutaneous lung biopsy: impact of lesion proximity to diaphragm on biopsy yield and pneumothorax rate. J Thorac Imaging 29:344–9
    • (2014) J Thorac Imaging , vol.29 , pp. 344-349
    • Patel, M.V.1    Ahmed, O.2    Jilani, D.3    Zangan, S.4
  • 33
    • 84860007179 scopus 로고    scopus 로고
    • CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose
    • PID: 21752567
    • Prosch H, Stadler A, Schilling M et al (2012) CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: accuracy, complications and radiation dose. Eur J Radiol 81:1029–33
    • (2012) Eur J Radiol , vol.81 , pp. 1029-1033
    • Prosch, H.1    Stadler, A.2    Schilling, M.3
  • 34
    • 15744399561 scopus 로고    scopus 로고
    • CT-guided automated cutting needle biopsy by a combined method for accurate specific diagnosis of focal lung lesions
    • PID: 15786749
    • Satoh S, Ohdama S, Matsubara O, Okochi Y, Tanaka R, Kimula Y (2005) CT-guided automated cutting needle biopsy by a combined method for accurate specific diagnosis of focal lung lesions. Radiat Med 23:30–6
    • (2005) Radiat Med , vol.23 , pp. 30-36
    • Satoh, S.1    Ohdama, S.2    Matsubara, O.3    Okochi, Y.4    Tanaka, R.5    Kimula, Y.6
  • 35
    • 77953151961 scopus 로고    scopus 로고
    • Evaluation of an interactive breath-hold control system in CT-guided lung biopsy
    • COI: 1:STN:280:DC%2BC3czpsVOgtg%3D%3D, PID: 20143287
    • Schoth F, Plumhans C, Kraemer N et al (2010) Evaluation of an interactive breath-hold control system in CT-guided lung biopsy. Röfo 182:507–11
    • (2010) Röfo , vol.182 , pp. 507-511
    • Schoth, F.1    Plumhans, C.2    Kraemer, N.3
  • 36
    • 84888051022 scopus 로고    scopus 로고
    • Immediate cytology improves accuracy and decreases complication rate in real-time computed tomography-guided needle lung biopsy
    • PID: 23239643
    • Tachibana K, Nakazato Y, Tsuchida S et al (2013) Immediate cytology improves accuracy and decreases complication rate in real-time computed tomography-guided needle lung biopsy. Diagn Cytopathol 41:1063–8
    • (2013) Diagn Cytopathol , vol.41 , pp. 1063-1068
    • Tachibana, K.1    Nakazato, Y.2    Tsuchida, S.3
  • 37
  • 38
    • 4544366568 scopus 로고    scopus 로고
    • Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies
    • PID: 15364752
    • Yeow K-M, Su I-H, Pan K-T et al (2004) Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies. Chest 126:748–54
    • (2004) Chest , vol.126 , pp. 748-754
    • Yeow, K.-M.1    Su, I.-H.2    Pan, K.-T.3
  • 39
    • 63649145063 scopus 로고    scopus 로고
    • CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications
    • PID: 18294798
    • Yildirim E, Kirbas I, Harman A et al (2009) CT-guided cutting needle lung biopsy using modified coaxial technique: factors effecting risk of complications. Eur J Radiol 70:57–60
    • (2009) Eur J Radiol , vol.70 , pp. 57-60
    • Yildirim, E.1    Kirbas, I.2    Harman, A.3
  • 40
    • 2342588136 scopus 로고    scopus 로고
    • Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients
    • PID: 15126658
    • Covey AM, Gandhi R, Brody LA, Getrajdman G, Thaler HT, Brown KT (2004) Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients. J Vasc Interv Radiol 15:479–83
    • (2004) J Vasc Interv Radiol , vol.15 , pp. 479-483
    • Covey, A.M.1    Gandhi, R.2    Brody, L.A.3    Getrajdman, G.4    Thaler, H.T.5    Brown, K.T.6
  • 41
    • 37849030524 scopus 로고    scopus 로고
    • Computed-tomographic-guided biopsy of thoracic nodules: a revision of 583 lesions
    • PID: 18265716
    • D’Alessandro V, Parracino T, Stranieri A et al (2007) Computed-tomographic-guided biopsy of thoracic nodules: a revision of 583 lesions. Clin Ter 158:509–13
    • (2007) Clin Ter , vol.158 , pp. 509-513
    • D’Alessandro, V.1    Parracino, T.2    Stranieri, A.3
  • 43
    • 36849010205 scopus 로고    scopus 로고
    • CT-guided percutaneous transthoracic needle biopsy of lung lesions - 2-Year experience at the Institute of Radiology in Ljubljana
    • Kocijancic I, Kocijancic K (2007) CT-guided percutaneous transthoracic needle biopsy of lung lesions - 2-Year experience at the Institute of Radiology in Ljubljana. Radiol Oncol 41:99–106
    • (2007) Radiol Oncol , vol.41 , pp. 99-106
    • Kocijancic, I.1    Kocijancic, K.2
  • 44
    • 0033917474 scopus 로고    scopus 로고
    • Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy
    • COI: 1:STN:280:DC%2BD3czksl2mtA%3D%3D, PID: 10887232
    • Lang EK, Ghavami R, Schreiner VC, Archibald S, Ramirez J (2000) Autologous blood clot seal to prevent pneumothorax at CT-guided lung biopsy. Radiology 216:93–6
    • (2000) Radiology , vol.216 , pp. 93-96
    • Lang, E.K.1    Ghavami, R.2    Schreiner, V.C.3    Archibald, S.4    Ramirez, J.5
  • 45
    • 55649115272 scopus 로고    scopus 로고
    • Percutaneous CT-guided fine-needle aspiration of pulmonary lesions: results and complications in 409 patients
    • COI: 1:STN:280:DC%2BD1cjmsFShsg%3D%3D, PID: 19032391
    • Laspas F, Roussakis A, Efthimiadou R, Papaioannou D, Papadopoulos S, Andreou J (2008) Percutaneous CT-guided fine-needle aspiration of pulmonary lesions: results and complications in 409 patients. J Med Imaging Radiat Oncol 52:458–62
    • (2008) J Med Imaging Radiat Oncol , vol.52 , pp. 458-462
    • Laspas, F.1    Roussakis, A.2    Efthimiadou, R.3    Papaioannou, D.4    Papadopoulos, S.5    Andreou, J.6
  • 46
    • 56749140897 scopus 로고    scopus 로고
    • Computed tomography-guided transthoracic needle aspiration biopsy of intrapulmonary lesions: utility of a liquid-based cytopreparatory technique
    • PID: 19068669
    • Lee YS, Jin GY, Han YM, Chung MJ, Park HS (2008) Computed tomography-guided transthoracic needle aspiration biopsy of intrapulmonary lesions: utility of a liquid-based cytopreparatory technique. Acta Cytol 52:665–70
    • (2008) Acta Cytol , vol.52 , pp. 665-670
    • Lee, Y.S.1    Jin, G.Y.2    Han, Y.M.3    Chung, M.J.4    Park, H.S.5
  • 47
    • 0142157645 scopus 로고    scopus 로고
    • Head and neck cancer patients with pulmonary nodules: value and role of CT-guided transthoracic needle aspiration biopsies
    • PID: 14603448
    • Mesurolle B, Mignon F, Meingan P, Domenge C, Vasile M, Sigal R (2003) Head and neck cancer patients with pulmonary nodules: value and role of CT-guided transthoracic needle aspiration biopsies. Head Neck 25:889–94
    • (2003) Head Neck , vol.25 , pp. 889-894
    • Mesurolle, B.1    Mignon, F.2    Meingan, P.3    Domenge, C.4    Vasile, M.5    Sigal, R.6
  • 48
    • 38949124072 scopus 로고    scopus 로고
    • CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less
    • COI: 1:STN:280:DC%2BD1c7hslGntg%3D%3D, PID: 18275867
    • Ng YL, Patsios D, Roberts H et al (2008) CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less. Clin Radiol 63:272–7
    • (2008) Clin Radiol , vol.63 , pp. 272-277
    • Ng, Y.L.1    Patsios, D.2    Roberts, H.3
  • 49
    • 72049086415 scopus 로고    scopus 로고
    • Chest computed tomography (CT) immediately after CT-guided transthoracic needle aspiration biopsy as a predictor of overt pneumothorax
    • PID: 19949733
    • Noh TJ, Lee CH, Kang YA et al (2009) Chest computed tomography (CT) immediately after CT-guided transthoracic needle aspiration biopsy as a predictor of overt pneumothorax. Korean J Intern Med 24:343–9
    • (2009) Korean J Intern Med , vol.24 , pp. 343-349
    • Noh, T.J.1    Lee, C.H.2    Kang, Y.A.3
  • 50
    • 77952682493 scopus 로고    scopus 로고
    • Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: a study based on the experience of the cytopathologist
    • PID: 20429755
    • Priola AM, Priola SM, Cataldi A et al (2010) Diagnostic accuracy and complication rate of CT-guided fine needle aspiration biopsy of lung lesions: a study based on the experience of the cytopathologist. Acta Radiol 51:527–33
    • (2010) Acta Radiol , vol.51 , pp. 527-533
    • Priola, A.M.1    Priola, S.M.2    Cataldi, A.3
  • 51
    • 0036285893 scopus 로고    scopus 로고
    • Intervention in patients with pneumothorax immediately following CT-guided fine needle aspiration of pulmonary nodules
    • PID: 12070429
    • Shantaveerappa HN, Mathai MG, Byrd RP Jr, Karnad AB, Mehta JB, Roy TM (2002) Intervention in patients with pneumothorax immediately following CT-guided fine needle aspiration of pulmonary nodules. Med Sci Monit 8:CR401–4
    • (2002) Med Sci Monit , vol.8 , pp. CR401-CR404
    • Shantaveerappa, H.N.1    Mathai, M.G.2    Byrd, R.P.3    Karnad, A.B.4    Mehta, J.B.5    Roy, T.M.6
  • 52
    • 84878333822 scopus 로고    scopus 로고
    • Does repeating CT-guided transthoracic fine needle aspiration increase diagnostic yield and complication rate? a single institution experience
    • PID: 24046779
    • Yazar E, Secik F, Yildiz P (2013) Does repeating CT-guided transthoracic fine needle aspiration increase diagnostic yield and complication rate? a single institution experience. Iran J Radiol 10:56–60
    • (2013) Iran J Radiol , vol.10 , pp. 56-60
    • Yazar, E.1    Secik, F.2    Yildiz, P.3
  • 53
    • 84871716153 scopus 로고    scopus 로고
    • Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions
    • PID: 23079048
    • Zhuang YP, Wang HY, Zhang J, Feng Y, Zhang L (2013) Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy in cavitary pulmonary lesions. Eur J Radiol 82:182–6
    • (2013) Eur J Radiol , vol.82 , pp. 182-186
    • Zhuang, Y.P.1    Wang, H.Y.2    Zhang, J.3    Feng, Y.4    Zhang, L.5
  • 54
    • 79961037018 scopus 로고    scopus 로고
    • Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records
    • PID: 21810706
    • Wiener RS, Schwartz LM, Woloshin S, Welch HG (2011) Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records. Ann Intern Med 155:137–44
    • (2011) Ann Intern Med , vol.155 , pp. 137-144
    • Wiener, R.S.1    Schwartz, L.M.2    Woloshin, S.3    Welch, H.G.4
  • 55
    • 33745223023 scopus 로고    scopus 로고
    • CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan
    • PID: 16530369
    • Tomiyama N, Yasuhara Y, Nakajima Y et al (2006) CT-guided needle biopsy of lung lesions: a survey of severe complication based on 9783 biopsies in Japan. Eur J Radiol 59:60–4
    • (2006) Eur J Radiol , vol.59 , pp. 60-64
    • Tomiyama, N.1    Yasuhara, Y.2    Nakajima, Y.3
  • 57
    • 34548026790 scopus 로고    scopus 로고
    • Nonfatal systemic air embolism complicating percutaneous CT-guided transthoracic needle biopsy: four cases from a single institution
    • PID: 17699141
    • Hiraki T, Fujiwara H, Sakurai J et al (2007) Nonfatal systemic air embolism complicating percutaneous CT-guided transthoracic needle biopsy: four cases from a single institution. Chest 132:684–90
    • (2007) Chest , vol.132 , pp. 684-690
    • Hiraki, T.1    Fujiwara, H.2    Sakurai, J.3
  • 58
    • 0031985261 scopus 로고    scopus 로고
    • Needle-track metastasis after transthoracic needle biopsy
    • COI: 1:STN:280:DyaK1c7gtFOrsw%3D%3D, PID: 9440831
    • Ayar D, Golla B, Lee JY, Nath H (1998) Needle-track metastasis after transthoracic needle biopsy. J Thorac Imaging 13:2–6
    • (1998) J Thorac Imaging , vol.13 , pp. 2-6
    • Ayar, D.1    Golla, B.2    Lee, J.Y.3    Nath, H.4
  • 59
    • 84856580700 scopus 로고    scopus 로고
    • Systemic air embolism during percutaneous core needle biopsy of the lung: frequency and risk factors
    • PID: 22309812
    • Freund MC, Petersen J, Goder KC, Bunse T, Wiedermann F, Glodny B (2012) Systemic air embolism during percutaneous core needle biopsy of the lung: frequency and risk factors. BMC Pulm Med 12:2
    • (2012) BMC Pulm Med , vol.12 , pp. 2
    • Freund, M.C.1    Petersen, J.2    Goder, K.C.3    Bunse, T.4    Wiedermann, F.5    Glodny, B.6
  • 61
    • 81055145962 scopus 로고    scopus 로고
    • Factors effecting risk of pneumothorax (PNX) in CT-guided transthoracic needle biopsy of lung lesions: results of 708 consecutive procedures
    • Priola AM, Novello S, Priola SM et al (2007) Factors effecting risk of pneumothorax (PNX) in CT-guided transthoracic needle biopsy of lung lesions: results of 708 consecutive procedures. J Thorac Oncol 2:S362
    • (2007) J Thorac Oncol , vol.2 , pp. S362
    • Priola, A.M.1    Novello, S.2    Priola, S.M.3
  • 62
    • 8744265055 scopus 로고    scopus 로고
    • Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung
    • PID: 15539721
    • Choi CM, Um SW, Yoo CG et al (2004) Incidence and risk factors of delayed pneumothorax after transthoracic needle biopsy of the lung. Chest 126:1516–21
    • (2004) Chest , vol.126 , pp. 1516-1521
    • Choi, C.M.1    Um, S.W.2    Yoo, C.G.3
  • 63
    • 0036247314 scopus 로고    scopus 로고
    • The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor
    • PID: 12006438
    • Saji H, Nakamura H, Tsuchida T et al (2002) The incidence and the risk of pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor. Chest 121:1521–6
    • (2002) Chest , vol.121 , pp. 1521-1526
    • Saji, H.1    Nakamura, H.2    Tsuchida, T.3
  • 64
    • 79951954625 scopus 로고    scopus 로고
    • CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance
    • PID: 20730613
    • Kim GR, Hur J, Lee SM et al (2011) CT fluoroscopy-guided lung biopsy versus conventional CT-guided lung biopsy: a prospective controlled study to assess radiation doses and diagnostic performance. Eur Radiol 21:232–9
    • (2011) Eur Radiol , vol.21 , pp. 232-239
    • Kim, G.R.1    Hur, J.2    Lee, S.M.3
  • 65
    • 85032039163 scopus 로고    scopus 로고
    • CT-fluoroscopy guided versus multislice ct biopsy mode guided lung biopsies: Accuracy, complications and radiation dose
    • Prosch H, Schilling M, Stadlert A, Eisenhuber E, Oschatz E, Mostbeck G (2009) CT-fluoroscopy guided versus multislice ct biopsy mode guided lung biopsies: Accuracy, complications and radiation dose. J Thorac Imaging 24:w25
    • (2009) J Thorac Imaging , vol.24 , pp. w25
    • Prosch, H.1    Schilling, M.2    Stadlert, A.3    Eisenhuber, E.4    Oschatz, E.5    Mostbeck, G.6
  • 66
    • 6044236701 scopus 로고    scopus 로고
    • Computed tomography-guided transthoracic fine-needle aspiration in diagnosis of lung cancer: a comparison of single-pass needle and multiple-pass coaxial needle systems and the value of immediate cytological assessment
    • PID: 15363014
    • Kucuk CU, Yilmaz A, Akkaya E (2004) Computed tomography-guided transthoracic fine-needle aspiration in diagnosis of lung cancer: a comparison of single-pass needle and multiple-pass coaxial needle systems and the value of immediate cytological assessment. Respirology 9:392–6
    • (2004) Respirology , vol.9 , pp. 392-396
    • Kucuk, C.U.1    Yilmaz, A.2    Akkaya, E.3
  • 67
    • 84947472092 scopus 로고    scopus 로고
    • Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients
    • Nour-Eldin N-EA, Alsubhi M, Emam A, et al (2015) Pneumothorax complicating coaxial and non-coaxial CT-guided lung biopsy: comparative analysis of determining risk factors and management of pneumothorax in a retrospective review of 650 patients. Cardiovasc Interv Radiol
    • (2015) Cardiovasc Interv Radiol
    • Nour-Eldin, N.-E.A.1    Alsubhi, M.2    Emam, A.3
  • 68
    • 0033397134 scopus 로고    scopus 로고
    • Pneumothorax post CT-guided lung biopsy: a comparison between detection on chest radiographs and CT
    • COI: 1:STN:280:DC%2BD3c7mvVWitQ%3D%3D, PID: 10703472
    • Bungay HK, Berger J, Traill ZC, Gleeson FV (1999) Pneumothorax post CT-guided lung biopsy: a comparison between detection on chest radiographs and CT. Br J Radiol 72:1160–3
    • (1999) Br J Radiol , vol.72 , pp. 1160-1163
    • Bungay, H.K.1    Berger, J.2    Traill, Z.C.3    Gleeson, F.V.4
  • 69
    • 84999543438 scopus 로고    scopus 로고
    • CT guided core biopsies in a county hospital in Sweden - Diagnostic yield and complication rate
    • Branden E, Wallgren S, Koyi H (2011) CT guided core biopsies in a county hospital in Sweden - Diagnostic yield and complication rate. Chest 140(4)
    • (2011) Chest , vol.140 , Issue.4
    • Branden, E.1    Wallgren, S.2    Koyi, H.3
  • 70
    • 0037369194 scopus 로고    scopus 로고
    • Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules?
    • PID: 12591702
    • Yamagami T, Iida S, Kato T, Tanaka O, Nishimura T (2003) Combining fine-needle aspiration and core biopsy under CT fluoroscopy guidance: a better way to treat patients with lung nodules? AJR Am J Roentgenol 180:811–5
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 811-815
    • Yamagami, T.1    Iida, S.2    Kato, T.3    Tanaka, O.4    Nishimura, T.5
  • 71
    • 33644650726 scopus 로고    scopus 로고
    • Transthoracic fine-needle aspiration vs concurrent core needle biopsy in diagnosis of intrathoracic lesions: a retrospective comparison of diagnostic accuracy
    • PID: 16613349
    • Gong Y, Sneige N, Guo M, Hicks ME, Moran CA (2006) Transthoracic fine-needle aspiration vs concurrent core needle biopsy in diagnosis of intrathoracic lesions: a retrospective comparison of diagnostic accuracy. Am J Clin Pathol 125:438–44
    • (2006) Am J Clin Pathol , vol.125 , pp. 438-444
    • Gong, Y.1    Sneige, N.2    Guo, M.3    Hicks, M.E.4    Moran, C.A.5
  • 72
    • 0030051348 scopus 로고    scopus 로고
    • Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients
    • COI: 1:STN:280:DyaK287psVSkug%3D%3D, PID: 8628859
    • Klein JS, Salomon G, Stewart EA (1996) Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients. Radiology 198:715–20
    • (1996) Radiology , vol.198 , pp. 715-720
    • Klein, J.S.1    Salomon, G.2    Stewart, E.A.3
  • 73
  • 74
    • 84863957973 scopus 로고    scopus 로고
    • Advances in fine needle aspiration cytology for the diagnosis of pulmonary carcinoma
    • PID: 21776344
    • Hasanovic A, Rekhtman N, Sigel CS, Moreira AL (2011) Advances in fine needle aspiration cytology for the diagnosis of pulmonary carcinoma. Patholog Res Int 2011:897292
    • (2011) Patholog Res Int , vol.2011 , pp. 897292
    • Hasanovic, A.1    Rekhtman, N.2    Sigel, C.S.3    Moreira, A.L.4
  • 75
    • 84908574660 scopus 로고    scopus 로고
    • Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screening
    • PID: 25282285
    • Horeweg N, van Rosmalen J, Heuvelmans MA et al (2014) Lung cancer probability in patients with CT-detected pulmonary nodules: a prespecified analysis of data from the NELSON trial of low-dose CT screening. Lancet Oncol 15:1332–41
    • (2014) Lancet Oncol , vol.15 , pp. 1332-1341
    • Horeweg, N.1    van Rosmalen, J.2    Heuvelmans, M.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.