Volumn 93, Issue 3, 2016, Pages 229-234

Decontamination of heater-cooler units associated with contamination by atypical mycobacteria

Author keywords

Cardiopulmonary bypass surgery; Decontamination; Heater cooler unit; Mycobacterium chimaera; Water

Indexed keywords

CHLORINE; PERACETIC ACID;

EID: 84963938755     PISSN: 01956701     EISSN: 15322939     Source Type: Journal    
DOI: 10.1016/j.jhin.2016.02.007     Document Type: Article
Times cited : (62)

References (15)
  • 1
    • 84938338068 scopus 로고    scopus 로고
    • Epidemiology and ecology of opportunistic premise plumbing pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa
    • Falkinham J.O., Hilborn E.D., Arduino M.J., Pruden A., Edwards M.A. Epidemiology and ecology of opportunistic premise plumbing pathogens: Legionella pneumophila, Mycobacterium avium, and Pseudomonas aeruginosa. Environ Health Perspect 2015, 123:749-758.
    • (2015) Environ Health Perspect , vol.123 , pp. 749-758
    • Falkinham, J.O.1    Hilborn, E.D.2    Arduino, M.J.3    Pruden, A.4    Edwards, M.A.5
  • 2
    • 10844263356 scopus 로고    scopus 로고
    • An outbreak of bacteremias associated with Mycobacterium mucogenicum in a hospital water supply
    • Kline S., Cameron S., Streifel A., et al. An outbreak of bacteremias associated with Mycobacterium mucogenicum in a hospital water supply. Infect Control Hosp Epidemiol 2004, 25:1042-1049.
    • (2004) Infect Control Hosp Epidemiol , vol.25 , pp. 1042-1049
    • Kline, S.1    Cameron, S.2    Streifel, A.3
  • 3
    • 0035448584 scopus 로고    scopus 로고
    • Mycobacterium xenopi spinal infections after discovertebral surgery: investigation and screening of a large outbreak
    • Astagneau P., Desplaces N., Vincent V., et al. Mycobacterium xenopi spinal infections after discovertebral surgery: investigation and screening of a large outbreak. Lancet 2001, 358(9283):747-751.
    • (2001) Lancet , vol.358 , Issue.9283 , pp. 747-751
    • Astagneau, P.1    Desplaces, N.2    Vincent, V.3
  • 4
    • 10844258919 scopus 로고    scopus 로고
    • Mycobacterium simae outbreak associated with a hospital water supply
    • Conger N.G., O'Connell R.J., Laurel V.L., et al. Mycobacterium simae outbreak associated with a hospital water supply. Infect Control Hosp Epidemiol 2004, 25:1050-1055.
    • (2004) Infect Control Hosp Epidemiol , vol.25 , pp. 1050-1055
    • Conger, N.G.1    O'Connell, R.J.2    Laurel, V.L.3
  • 5
    • 84948671530 scopus 로고    scopus 로고
    • Prolonged outbreak of Mycobacterium chimaera infection after open-chest heart surgery
    • Sax H., Bloemberg G., Hasse B., et al. Prolonged outbreak of Mycobacterium chimaera infection after open-chest heart surgery. Clin Infect Dis 2015, 61:67-75.
    • (2015) Clin Infect Dis , vol.61 , pp. 67-75
    • Sax, H.1    Bloemberg, G.2    Hasse, B.3
  • 6
    • 84973308024 scopus 로고    scopus 로고
    • Rapid risk assessment, invasive cardiovascular infection by Mycobacterium chimaera potentially associated with heater cooler units used during cardiac surgery
    • April 2015. [last accessed February].
    • European Centre for Disease Prevention and Control. Rapid risk assessment, invasive cardiovascular infection by Mycobacterium chimaera potentially associated with heater cooler units used during cardiac surgery. April 2015. Available at: [last accessed February 2016]. http://ecdc.europa.eu/en/publications/Publications/mycobacterium-chimaera-infection-associated-with-heater-cooler-units-rapid-risk-assessment-30-April-2015.pdf.
    • (2016)
  • 7
    • 84948684471 scopus 로고    scopus 로고
    • Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery
    • Kohler P., Kutser S.P., Bloemberg G., et al. Healthcare-associated prosthetic heart valve, aortic vascular graft, and disseminated Mycobacterium chimaera infections subsequent to open heart surgery. Eur Heart J 2015, 36:2745-2753.
    • (2015) Eur Heart J , vol.36 , pp. 2745-2753
    • Kohler, P.1    Kutser, S.P.2    Bloemberg, G.3
  • 9
    • 84973359808 scopus 로고    scopus 로고
    • Heater Cooler System 3T, operating instructions
    • Version 02/2015. [last accessed February].
    • Sorin Group. Heater Cooler System 3T, operating instructions. Version 02/2015. Available at: [last accessed February 2016]. http://www.livanova.sorin.com/products/cardiac-surgery/perfusion/hlm/3t.
    • (2016)
  • 11
    • 84973329179 scopus 로고    scopus 로고
    • Infections associated with heater cooler units in cardiopulmonary bypass and ECMO
    • October 2015. [last accessed February 2016].
    • Public Health England. Infections associated with heater cooler units in cardiopulmonary bypass and ECMO. Information for healthcare providers in England, October 2015. Available at: [last accessed February 2016]. https://www.gov.uk/government/uploads/system/uploads/attachment_data/file/474218/Infections_associated_with_heater_cooler_units_version_1.pdf.
    • Information for healthcare providers in England
  • 12
    • 84973314131 scopus 로고    scopus 로고
    • Heater cooler devices used during cardiac surgery: risk of infection with Mycobacterium species. All manufacturers
    • June 2015. [last accessed February 2016].
    • Medical Device Alert, MDA/2015/022. Heater cooler devices used during cardiac surgery: risk of infection with Mycobacterium species. All manufacturers. June 2015. Available at: [last accessed February 2016]. https://assets.digital.cabinet-office.gov.uk/media/557958c640f0b615b8000025/MDA-2015-022_Heater-coolers.pdf.
  • 13
    • 77952283792 scopus 로고    scopus 로고
    • Inhibitory effect of biocides on the viable masses and matrices of Staphylococcus aureus and Pseudomonas aeruginosa biofilms
    • Toté K., Horemans T., Vanden Berghe D., Maes L., Cos P. Inhibitory effect of biocides on the viable masses and matrices of Staphylococcus aureus and Pseudomonas aeruginosa biofilms. Appl Environ Microbiol 2010, 76:3135-3142.
    • (2010) Appl Environ Microbiol , vol.76 , pp. 3135-3142
    • Toté, K.1    Horemans, T.2    Vanden Berghe, D.3    Maes, L.4    Cos, P.5
  • 14
    • 33750497656 scopus 로고    scopus 로고
    • Hospital outbreak of atypical mycobacterial infection of port sites after laparoscopic surgery
    • Vijayaraghavan R., Chandrashekhar R., Sujatha Y., Belagavi C.S. Hospital outbreak of atypical mycobacterial infection of port sites after laparoscopic surgery. J Hosp Infect 2006, 64:344-347.
    • (2006) J Hosp Infect , vol.64 , pp. 344-347
    • Vijayaraghavan, R.1    Chandrashekhar, R.2    Sujatha, Y.3    Belagavi, C.S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.