메뉴 건너뛰기




Volumn 2015-October, Issue , 2015, Pages 596-599

Contamination and AC pollution flashover characteristics of insulators under fog-haze environment

Author keywords

contamination; flashover voltage; fog haze; insulators; leakage current

Indexed keywords

CONTAMINATION; ELECTRIC INSULATORS; FLASHOVER; FOG; GLASS; INSULATING MATERIALS; LEAKAGE CURRENTS; MOISTURE; POLLUTION; PORCELAIN;

EID: 84962524122     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICPADM.2015.7295342     Document Type: Conference Paper
Times cited : (22)

References (14)
  • 1
    • 77950352820 scopus 로고    scopus 로고
    • Natural pollution test of composite and porcelain insulators under AC and DC stress
    • September
    • WANG Bin, LIANG Xidong, ZHANG Yibo, et al, "Natural pollution test of composite and porcelain insulators under AC and DC stress," High Voltage Engineering. China, Vol. 35, pp. 2322-2328, September 2009
    • (2009) High Voltage Engineering. China , vol.35 , pp. 2322-2328
    • Bin, W.1    Xidong, L.2    Yibo, Z.3
  • 2
    • 77950351405 scopus 로고    scopus 로고
    • Natural pollution deposit test of polymeric insulators operated under DC voltage
    • July
    • LI Zhenyu, LIANG Xidong, WANG Bin and ZHOU Yuanxiang, "Natural pollution deposit test of polymeric insulators operated under DC voltage," Power System Technology. China, Vol. 31, pp.10-14, July 2007
    • (2007) Power System Technology. China , vol.31 , pp. 10-14
    • Zhenyu, L.I.1    Xidong, L.2    Bin, W.3    Yuanxiang, Z.4
  • 3
    • 51849136803 scopus 로고    scopus 로고
    • A preliminary discussion on accumulated contamination regular pattern on composite insulators
    • May
    • WAND Biao, CHEN Huanjin and CHEN Wei, "A preliminary discussion on accumulated contamination regular pattern on composite insulators," Hebei Electric Power. China, Vol. 22, pp.30-32, May 2003
    • (2003) Hebei Electric Power. China , vol.22 , pp. 30-32
    • Biao, W.1    Huanjin, C.2    Wei, C.3
  • 4
    • 84869159518 scopus 로고    scopus 로고
    • Contrast observation on the contamination characteristics on line charged composite insulator
    • October
    • JIANG Jianwu, ZHAO Ling, FANG C'hunhua, et al, "Contrast observation on the contamination characteristics on line charged composite insulator," High Voltage Engineering. China, Vol. 38, pp. 2633-2639, October 2012
    • (2012) High Voltage Engineering. China , vol.38 , pp. 2633-2639
    • Jianwu, J.1    Ling, Z.2    C'Hunhua, F.3
  • 5
    • 84877885565 scopus 로고    scopus 로고
    • Comparison and analysis on natural contamination characteristics of uncharged composite insulator and XP-70 insulator
    • April
    • WAND Jianguo, WAND Kang, YAO Senjing, ZHAO Ling and FANG Chunhua, "Comparison and analysis on natural contamination characteristics of uncharged composite insulator and XP-70 insulator," High Voltage Engineering. China, Vol. 39, pp. 957-963, April 2013
    • (2013) High Voltage Engineering. China , vol.39 , pp. 957-963
    • Jianguo, W.1    Kang, W.2    Senjing, Y.3    Ling, Z.4    Chunhua, F.5
  • 6
    • 3142720700 scopus 로고    scopus 로고
    • Comparision of natural contaminants accumulated on surfaces of suspension and post insulators with DC and AC stress in northern China's inland areas
    • May
    • SU Zhiyi and LIU Yansheng, "Comparision of natural contaminants accumulated on surfaces of suspension and post insulators with DC and AC stress in northern China's inland areas," Power System Technology. China, Vol. 28, pp. 13-17, May 2004
    • (2004) Power System Technology. China , vol.28 , pp. 13-17
    • Zhiyi, S.U.1    Yansheng, L.2
  • 7
    • 0042711085 scopus 로고    scopus 로고
    • Elementary analysis of pollution rules of insulators on±500 kV DC transmission lines
    • June
    • CAI Wei, XIAO Yong and WU Guangya, "Elementary analysis of pollution rules of insulators on±500 kV DC transmission lines," High Voltage Engineering. China, Vol. 29, pp. 4, 40, June 2003
    • (2003) High Voltage Engineering. China , vol.29 , pp. 4-40
    • Wei, C.1    Yong, X.2    Guangya, W.U.3
  • 8
    • 84962608949 scopus 로고    scopus 로고
    • AC pollution flashover performance of standard suspension insulators at high altitude sites
    • May
    • YUAN Jihe, JINAG Xingliang, ZHANG Zhijin, HU Jianlin and SUN Caixin, "AC pollution flashover performance of standard suspension insulators at high altitude sites," Power System Technology. China, Vol. 35, pp. 58-61, May 2009
    • (2009) Power System Technology. China , vol.35 , pp. 58-61
    • Jihe, Y.1    Xingliang, J.2    Zhijin, Z.3    Jianlin, H.U.4    Caixin, S.5
  • 9
    • 33749005639 scopus 로고    scopus 로고
    • Influence of ESDD and NSDD on AC flashover characteristic of artificially polluted XP-160 insulators
    • August
    • JINAG Xingliang, SHU Lichun, ZHANG Yongji, ZHANG Zhijin and HU Jianlin, "Influence of ESDD and NSDD on AC flashover characteristic of artificially polluted XP-160 insulators," Proceedings of the CSEE. China, Vol. 26, pp. 24-28, August 2006
    • (2006) Proceedings of the CSEE. China , vol.26 , pp. 24-28
    • Xingliang, J.1    Lichun, S.2    Yongji, Z.3    Zhijin, Z.4    Jianlin, H.U.5
  • 10
    • 33745661241 scopus 로고    scopus 로고
    • Effect of both salt and non-soluble deposit densities on flashover voltage of 110kV composite insulator
    • May
    • JIANG Xingliang, CHEN Aijun, ZHANG Zhijin, HU Jianlin and SUN Caixin, "Effect of both salt and non-soluble deposit densities on flashover voltage of 110kV composite insulator," Proceedings of the CSEE. China, Vol. 26, pp. 150-154, May 2006
    • (2006) Proceedings of the CSEE. China , vol.26 , pp. 150-154
    • Xingliang, J.1    Aijun, C.2    Zhijin, Z.3    Jianlin, H.U.4    Caixin, S.5
  • 11
    • 77249128992 scopus 로고    scopus 로고
    • Investigation of flashover voltage and non-uniform pollution correction coefficient of short samples of composite insulator intended for ± 800 kV UHVDC
    • January
    • JIANG Xingliang, WANG Shaohua., ZHANG Zhijin, HU Jianlin and HU Qin, "Investigation of flashover voltage and non-uniform pollution correction coefficient of short samples of composite insulator intended for ± 800 kV UHVDC," IEEE Trans. Dielectr. Electr. Insul. Vol. 17, pp. 71-80, January 2010
    • (2010) IEEE Trans. Dielectr. Electr. Insul , vol.17 , pp. 71-80
    • Xingliang, J.1    Shaohua, W.2    Zhijin, Z.3    Jianlin, H.U.4    Qin, H.U.5
  • 12
    • 33745121642 scopus 로고    scopus 로고
    • Artificial pollution tests on high-voltage insulators to be used on AC systems
    • Beijing: Standard Press of China
    • "Artificial pollution tests on high-voltage insulators to be used on AC systems," GB/T4585-2004, Beijing: Standard Press of China, 2004
    • (2004) GB/T4585-2004
  • 13
    • 84962499478 scopus 로고    scopus 로고
    • Selection and dimensioning of high voltage for polluted conditions, part 1: Definitions, information and general principles
    • "Selection and dimensioning of high voltage for polluted conditions, part 1: definitions, information and general principles," IEC60815-1 Geneva: International Organization for Standardization, 2002
    • (2002) IEC60815-1 Geneva: International Organization for Standardization
  • 14
    • 84880345742 scopus 로고    scopus 로고
    • Research of adhesion force between dust particles and insulator surface using atomic force microscope
    • June
    • WANG Jing, LI Yan, LIANG Xidong and LIU Yingyan, "Research of adhesion force between dust particles and insulator surface using atomic force microscope," High Voltage Engineering. China, Vol. 39, pp. 1352-1359, June 2013
    • (2013) High Voltage Engineering. China , vol.39 , pp. 1352-1359
    • Jing, W.1    Yan, L.I.2    Xidong, L.3    Yingyan, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.