메뉴 건너뛰기




Volumn 9401, Issue , 2016, Pages 28-35

Improving patient specific neurosurgical models with intraoperative ultrasound and augmented reality visualizations in a neuronavigation environment

Author keywords

[No Author keywords available]

Indexed keywords

AUGMENTED REALITY; BIOINFORMATICS; NEUROSURGERY; ULTRASONIC IMAGING; VISUALIZATION;

EID: 84962383059     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/978-3-319-31808-0_4     Document Type: Conference Paper
Times cited : (8)

References (11)
  • 1
    • 0022505393 scopus 로고
    • A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope
    • Roberts, D.W., et al.: A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. J. Neurosurg. 65(4), 545–549 (1986)
    • (1986) J. Neurosurg , vol.65 , Issue.4 , pp. 545-549
    • Roberts, D.W.1
  • 2
    • 84945466920 scopus 로고    scopus 로고
    • Augmented reality in neurovascular surgery: Feasibility and first uses in the operating room
    • Kersten-Oertel, M., et al.: Augmented reality in neurovascular surgery: Feasibility and first uses in the operating room. Int. J. Comput. Assist. Radiol. Surg. 10(11), 1823–1836 (2015)
    • (2015) Int. J. Comput. Assist. Radiol. Surg , vol.10 , Issue.11 , pp. 1823-1836
    • Kersten-Oertel, M.1
  • 3
    • 79960559000 scopus 로고    scopus 로고
    • New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: System description and validation
    • Mercier, L., et al.: New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: System description and validation. Int. J. Comput. Assist. Radiol. Surg. 6(4), 507–522 (2011)
    • (2011) Int. J. Comput. Assist. Radiol. Surg , vol.6 , Issue.4 , pp. 507-522
    • Mercier, L.1
  • 4
    • 84879724941 scopus 로고    scopus 로고
    • A new method for structural volume analysis of longitudinal brain MRI data and its application in studying the growth trajectories of anatomical brain structures in childhood
    • Aubert-Broche, B., et al.: A new method for structural volume analysis of longitudinal brain MRI data and its application in studying the growth trajectories of anatomical brain structures in childhood. Neuroimage 82, 393–402 (2013)
    • (2013) Neuroimage , vol.82 , pp. 393-402
    • Aubert-Broche, B.1
  • 5
    • 41649106122 scopus 로고    scopus 로고
    • An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images
    • Coupe, P., et al.: An optimized blockwise nonlocal means denoising filter for 3-D magnetic resonance images. IEEE Trans. Med. Imaging 27(4), 425–441 (2008)
    • (2008) IEEE Trans. Med. Imaging , vol.27 , Issue.4 , pp. 425-441
    • Coupe, P.1
  • 6
    • 0031987382 scopus 로고    scopus 로고
    • A nonparametric method for automatic correction of intensity nonuniformity in MRI data
    • Sled, J.G., Zijdenbos, A.P., Evans, A.C.: A nonparametric method for automatic correction of intensity nonuniformity in MRI data. IEEE Trans. Med. Imaging 17(1), 87–97 (1998)
    • (1998) IEEE Trans. Med. Imaging , vol.17 , Issue.1 , pp. 87-97
    • Sled, J.G.1    Zijdenbos, A.P.2    Evans, A.C.3
  • 7
    • 33750281106 scopus 로고    scopus 로고
    • Active surface approach for extraction of the human cerebral cortex from MRI
    • In: Larsen, R., Nielsen, M., Sporring, J. (eds.), Springer, Heidelberg
    • Eskildsen, S.F., Østergaard, L.R.: Active surface approach for extraction of the human cerebral cortex from MRI. In: Larsen, R., Nielsen, M., Sporring, J. (eds.) MICCAI 2006. LNCS, vol. 4191, pp. 823–830. Springer, Heidelberg (2006)
    • (2006) MICCAI 2006. LNCS , vol.4191 , pp. 823-830
    • Eskildsen, S.F.1    Østergaard, L.R.2
  • 8
    • 84880230985 scopus 로고    scopus 로고
    • Fast rigid registration of pre-operative magnetic resonance images to intra-operative ultrasound for neurosurgery based on high confidence gradient orientations
    • De Nigris, D., Collins, D.L., Arbel, T.: Fast rigid registration of pre-operative magnetic resonance images to intra-operative ultrasound for neurosurgery based on high confidence gradient orientations. Int. J. Comput. Assist. Radiol. Surg. 8(4), 649–661 (2013)
    • (2013) Int. J. Comput. Assist. Radiol. Surg , vol.8 , Issue.4 , pp. 649-661
    • De Nigris, D.1    Collins, D.L.2    Arbel, T.3
  • 9
    • 84867492785 scopus 로고    scopus 로고
    • A realistic test and development environment for mixed reality in neurosurgery
    • In: Linte, C.A., Moore, J.T., Chen, E.C., Holmes III, D.R. (eds.), Springer, Heidelberg
    • Drouin, S., Kersten-Oertel, M., Chen, S.J.-S., Collins, D.: A realistic test and development environment for mixed reality in neurosurgery. In: Linte, C.A., Moore, J.T., Chen, E.C., Holmes III, D.R. (eds.) AE-CAI 2011. LNCS, vol. 7264, pp. 13–23. Springer, Heidelberg (2012)
    • (2012) AE-CAI 2011. LNCS , vol.7264 , pp. 13-23
    • Drouin, S.1    Kersten-Oertel, M.2    Chen, S.J.3    Collins, D.4
  • 10
    • 84860627008 scopus 로고    scopus 로고
    • Augmented reality visualization for guidance in neurovascular surgery. Stud. Health Technol
    • Kersten-Oertel, M., et al.: Augmented reality visualization for guidance in neurovascular surgery. Stud. Health Technol. Inform. 173, 225–229 (2012)
    • (2012) Inform , vol.173 , pp. 225-229
    • Kersten-Oertel, M.1
  • 11
    • 44849129210 scopus 로고    scopus 로고
    • Augmented reality endoscopic system (ARES): Preliminary results
    • Caversaccio, M., et al.: Augmented reality endoscopic system (ARES): preliminary results. Rhinology 46(2), 156–158 (2008)
    • (2008) Rhinology , vol.46 , Issue.2 , pp. 156-158
    • Caversaccio, M.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.