메뉴 건너뛰기




Volumn 118, Issue , 2016, Pages 27-36

Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin façade

Author keywords

Double skin fa ade; EnergyPlus; Multi storey office building; Statistical indicators; Validation

Indexed keywords

AIR; COMPUTER SOFTWARE; OFFICE BUILDINGS;

EID: 84962329568     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2016.02.045     Document Type: Article
Times cited : (116)

References (24)
  • 1
    • 0242335863 scopus 로고    scopus 로고
    • Optimal operation of a south double skin facade
    • E. Gratia, and A. De Herde Optimal operation of a south double skin facade Energy Build. 36 2003 41 60
    • (2003) Energy Build. , vol.36 , pp. 41-60
    • Gratia, E.1    De Herde, A.2
  • 2
    • 33847637178 scopus 로고    scopus 로고
    • Are energy consumptions decreased with the addition of a double-skin
    • E. Gratia, and A. De Herde Are energy consumptions decreased with the addition of a double-skin Energy Build. 39 2007 605 619
    • (2007) Energy Build. , vol.39 , pp. 605-619
    • Gratia, E.1    De Herde, A.2
  • 3
    • 0036457831 scopus 로고    scopus 로고
    • Modeling simulation of a double-skin facade system
    • J. Hensen, M. Bartak, and F. Drkal Modeling simulation of a double-skin facade system ASHRAE Trans. 108 2 2002 1251 1259
    • (2002) ASHRAE Trans. , vol.108 , Issue.2 , pp. 1251-1259
    • Hensen, J.1    Bartak, M.2    Drkal, F.3
  • 4
    • 80755144036 scopus 로고    scopus 로고
    • Difficulties and limitations in performance simulation of a double skin facade with EnergyPlus
    • D. Kim, and C. Park Difficulties and limitations in performance simulation of a double skin facade with EnergyPlus Energy Build. 43 2011 3635 3645
    • (2011) Energy Build. , vol.43 , pp. 3635-3645
    • Kim, D.1    Park, C.2
  • 6
    • 84861795411 scopus 로고    scopus 로고
    • Operation and control strategies for multi-storey double skin facades during the heating season
    • W. Choi, J. Joe, Y. Kwak, and J.-H. Huh Operation and control strategies for multi-storey double skin facades during the heating season Energy Build. 49 2012 454 465
    • (2012) Energy Build. , vol.49 , pp. 454-465
    • Choi, W.1    Joe, J.2    Kwak, Y.3    Huh, J.-H.4
  • 7
    • 84873889604 scopus 로고    scopus 로고
    • Load characteristics and operation strategies of building integrated with multi story double skin facade
    • J. Joe, W. Choi, Y. Kwak, and J.-H. Huh Load characteristics and operation strategies of building integrated with multi story double skin facade Energy Build. 60 2013 185 198
    • (2013) Energy Build. , vol.60 , pp. 185-198
    • Joe, J.1    Choi, W.2    Kwak, Y.3    Huh, J.-H.4
  • 8
    • 84896981085 scopus 로고    scopus 로고
    • Optimal design of a multi-story double skin facade
    • J. Joe, W. Choi, Y. Kwak, and J.-H. Huh Optimal design of a multi-story double skin facade Energy Build. 76 2014 143 150
    • (2014) Energy Build. , vol.76 , pp. 143-150
    • Joe, J.1    Choi, W.2    Kwak, Y.3    Huh, J.-H.4
  • 9
    • 84896516439 scopus 로고    scopus 로고
    • Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell
    • N. Mateus, and et al. Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell Energy Build. 75 2014 511 522
    • (2014) Energy Build. , vol.75 , pp. 511-522
    • Mateus, N.1
  • 10
    • 84911900253 scopus 로고    scopus 로고
    • Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facrossed d signade
    • A.S. Ancrossed d signelković, and et al. Experimental research of the thermal characteristics of a multi-storey naturally ventilated double skin facrossed d signade Energy Build. 86 2015 766 781
    • (2015) Energy Build. , vol.86 , pp. 766-781
    • Ancrossed D Signelković, A.S.1
  • 17
    • 33746233629 scopus 로고    scopus 로고
    • Series of experiments for empirical validation of solar gain modeling in building energy simulation codes-experimental setup, test cell characterization, specifications and uncertainty analysis
    • H. Manz, and et al. Series of experiments for empirical validation of solar gain modeling in building energy simulation codes-experimental setup, test cell characterization, specifications and uncertainty analysis Build. Environ. 41 2006 1784 1797
    • (2006) Build. Environ. , vol.41 , pp. 1784-1797
    • Manz, H.1
  • 18
    • 69349093895 scopus 로고    scopus 로고
    • Investigation on energy performance of double skin facade in Hong Kong
    • A.L.S. Chan, T.T. Chow, K.F. Fong, and Z. Lin Investigation on energy performance of double skin facade in Hong Kong Energy Build. 41 2009 1135 1142
    • (2009) Energy Build. , vol.41 , pp. 1135-1142
    • Chan, A.L.S.1    Chow, T.T.2    Fong, K.F.3    Lin, Z.4
  • 19
    • 84976391058 scopus 로고    scopus 로고
    • An empirical validation of building simulation software for modeling of doubleskin facade (DSF)
    • Glasgow, Scotland
    • O. Kalyanova et al., An empirical validation of building simulation software for modeling of doubleskin facade (DSF), Proceedings of 11th International Conference on Building Simulation, Glasgow, Scotland (2009)
    • (2009) Proceedings of 11th International Conference on Building Simulation
    • Kalyanova, O.1
  • 20
    • 79951517121 scopus 로고    scopus 로고
    • Empirical validation and modelling of a naturally ventilated rainscreen facade building
    • C. Marinosci, and et al. Empirical validation and modelling of a naturally ventilated rainscreen facade building Energy Build. 43 2011 853 886
    • (2011) Energy Build. , vol.43 , pp. 853-886
    • Marinosci, C.1
  • 21
    • 79960734626 scopus 로고    scopus 로고
    • Assessment of natural and hybrid ventilation models in whole-building energy simulations
    • Z. Zhai, and et al. Assessment of natural and hybrid ventilation models in whole-building energy simulations Energy Build. 43 2011 2251 2261
    • (2011) Energy Build. , vol.43 , pp. 2251-2261
    • Zhai, Z.1
  • 22
    • 67449143232 scopus 로고    scopus 로고
    • Contribution of natural ventilation in a double skin envelope to heating load reduction in winter
    • Y. Kim, and et al. Contribution of natural ventilation in a double skin envelope to heating load reduction in winter Build. Environ. 44 2009 2236 2244
    • (2009) Build. Environ. , vol.44 , pp. 2236-2244
    • Kim, Y.1
  • 23
    • 77955566336 scopus 로고    scopus 로고
    • Thermal behaviour of a ventilated double skin facade in hot arid climate
    • N. Hashemi, and et al. Thermal behaviour of a ventilated double skin facade in hot arid climate Energy Build. 42 2010 1823 1832
    • (2010) Energy Build. , vol.42 , pp. 1823-1832
    • Hashemi, N.1
  • 24
    • 84875208432 scopus 로고    scopus 로고
    • Numerical modelling of ventilated facades: A review
    • A. De Gracia, and et al. Numerical modelling of ventilated facades: A review Renew. Sustain. Energy Rev. 22 2013 539 549
    • (2013) Renew. Sustain. Energy Rev. , vol.22 , pp. 539-549
    • De Gracia, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.