메뉴 건너뛰기




Volumn 12, Issue 4, 2005, Pages 15-19

Effect of the irregular inner shape of a glass vessel on prednisone dissolution results

Author keywords

[No Author keywords available]

Indexed keywords

PREDNISONE;

EID: 84962103849     PISSN: 1521298X     EISSN: None     Source Type: Journal    
DOI: 10.14227/DT120405P15     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 0028907748 scopus 로고
    • Evaluation of the performance of prednisone and salicylic acid USP dissolution calibrators
    • Achanta, A, S., Gray, V. A., Cecil, T. L., Grady, L. T., "Evaluation of the performance of prednisone and salicylic acid USP dissolution calibrators," Drug Dev. Ind. Pharm., 21, 1171-1182, 1995.
    • (1995) Drug Dev. Ind. Pharm , vol.21 , pp. 1171-1182
    • Achanta, A.S.1    Gray, V.A.2    Cecil, T.L.3    Grady, L.T.4
  • 2
    • 71649116235 scopus 로고    scopus 로고
    • Typical variability in dissolution testing and its qualification
    • Kaniwa, N., " Typical variability in dissolution testing and its qualification," Pharm. Tech. Japan, 18, 105-111, 2002.
    • (2002) Pharm. Tech. Japan , vol.18 , pp. 105-111
    • Kaniwa, N.1
  • 3
    • 33845185965 scopus 로고
    • Calibration of dissolution rate apparatuses: A User's Perspective
    • (Fall)
    • Skoug, J. W., " Calibration of dissolution rate apparatuses: A User's Perspective," Dissolution Technologies, 1(2, Fall), 3-5, 1994.
    • (1994) Dissolution Technologies , vol.1 , Issue.2 , pp. 3-5
    • Skoug, J.W.1
  • 4
    • 0032923660 scopus 로고    scopus 로고
    • Typical variability in drug dissolution testing: Study with USP and FDA calibrator tablets and a marketed drug (glibenclamide) product
    • Qureshi, S. A., McGilveray, I. J., "Typical variability in drug dissolution testing: study with USP and FDA calibrator tablets and a marketed drug (glibenclamide) product," Eur. J. Pharm. Sci. 7, 249-258, 1999.
    • (1999) Eur. J. Pharm. Sci , vol.7 , pp. 249-258
    • Qureshi, S.A.1    McGilveray, I.J.2
  • 5
    • 0036061632 scopus 로고    scopus 로고
    • Identifying source of error and variability in dissolution calibration and sample testing
    • Summer, 8
    • Gray, V. A., "Identifying source of error and variability in dissolution calibration and sample testing," American Pharmaceutical Review, Summer, 8, 2002.
    • (2002) American Pharmaceutical Review
    • Gray, V.A.1
  • 6
    • 0020085526 scopus 로고
    • Systematic error associated with apparatus 2 of the USP dissolution test II: Effects of deviations in vessel curvature from that of a sphere
    • Cox, D. C., Wells, C. E., Furman, W. B., Savage, T. S., King, A. C., "Systematic error associated with apparatus 2 of the USP dissolution test II: Effects of deviations in vessel curvature from that of a sphere," J. Pharm. Sci., 71, 395-399, 1982.
    • (1982) J. Pharm. Sci , vol.71 , pp. 395-399
    • Cox, D.C.1    Wells, C.E.2    Furman, W.B.3    Savage, T.S.4    King, A.C.5
  • 7
    • 84974623989 scopus 로고    scopus 로고
    • Geometric Irregularities Common to the Dissolution Vessel
    • (February)
    • Scott, P., "Geometric Irregularities Common to the Dissolution Vessel," Dissolution Technologies, 12, (1, February), 18-21, 2005.
    • (2005) Dissolution Technologies , vol.12 , Issue.1 , pp. 18-21
    • Scott, P.1
  • 11
    • 0005707565 scopus 로고    scopus 로고
    • Pharmacopeial Forum, 27, 3432-3439, 2001.
    • (2001) Pharmacopeial Forum , vol.27 , pp. 3432-3439
  • 12
    • 0033674245 scopus 로고    scopus 로고
    • Cause of high variability in drug dissolution testing and its impact on setting tolerances
    • Qureshi, S. A., Shabnam, J., " Cause of high variability in drug dissolution testing and its impact on setting tolerances," Eur. J. Pharm. Sci., 12, 271-276, 2001.
    • (2001) Eur. J. Pharm. Sci , vol.12 , pp. 271-276
    • Qureshi, S.A.1    Shabnam, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.