-
1
-
-
84859509560
-
2012 hrs/ehra/ecas expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design
-
Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen S-A, et al. 2012 HRS/EHRA/ECAS Expert Consensus Statement on Catheter and Surgical Ablation of Atrial Fibrillation: recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 2012; 14: 528-606
-
(2012)
Europace
, vol.14
, pp. 528-606
-
-
Calkins, H.1
Kuck, K.H.2
Cappato, R.3
Brugada, J.4
Camm, A.J.5
Chen, S.-A.6
-
2
-
-
47149112945
-
Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study
-
Neumann T, Vogt J, Schumacher B, Dorszewski A, KunissM, NeuserHet al. Circumferential pulmonary vein isolation with the cryoballoon technique results from a prospective 3-center study. J Am Coll Cardiol 2008; 52: 273-8
-
(2008)
J Am Coll Cardiol
, vol.52
, pp. 273-278
-
-
Neumann, T.1
Vogt, J.2
Schumacher, B.3
Dorszewski, A.4
Kuniss, M.5
Neuser, H.6
-
3
-
-
59749099384
-
Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter
-
Boersma LVA, Wijffels MCEF, Oral H, Wever EFD, Morady F. Pulmonary vein isolation by duty-cycled bipolar and unipolar radiofrequency energy with a multielectrode ablation catheter. Heart Rhythm 2008; 5: 1635-42
-
(2008)
Heart Rhythm
, vol.5
, pp. 1635-1642
-
-
Boersma, L.V.A.1
Wijffels, M.C.E.F.2
Oral, H.3
Wever, E.F.D.4
Morady, F.5
-
4
-
-
34247364622
-
Pulmonary vein isolation by high-intensity focused ultrasound: First-in-man study with a steerable balloon catheter
-
Schmidt B, Antz M, Ernst S, Ouyang F, Falk P, Chun JKR, et al. Pulmonary vein isolation by high-intensity focused ultrasound: first-in-man study with a steerable balloon catheter. Heart Rhythm 2007; 4: 575-84
-
(2007)
Heart Rhythm
, vol.4
, pp. 575-584
-
-
Schmidt, B.1
Antz, M.2
Ernst, S.3
Ouyang, F.4
Falk, P.5
Chun, J.K.R.6
-
5
-
-
84883748037
-
Comparison of balloon catheter ablation technologies for pulmonary vein isolation: The laser versus cryo study
-
Bordignon S, Chun KRJ, Gunawardene M, Fuernkranz A, Urban V, Schulte-Hahn B, et al. Comparison of balloon catheter ablation technologies for pulmonary vein isolation: the laser versus cryo study. J Cardiovasc Electrophysiol 2013; 24: 987-94
-
(2013)
J Cardiovasc Electrophysiol
, vol.24
, pp. 987-994
-
-
Bordignon, S.1
Chun, K.R.J.2
Gunawardene, M.3
Fuernkranz, A.4
Urban, V.5
Schulte-Hahn, B.6
-
6
-
-
79961179981
-
Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: Comparison of different atrial fibrillation ablation technologies in a multicenter study
-
Herrera Siklódy C, Deneke T, Hocini M, Lehrmann H, Shin D-I, Miyazaki S, et al. Incidence of asymptomatic intracranial embolic events after pulmonary vein isolation: comparison of different atrial fibrillation ablation technologies in a multicenter study. J Am Coll Cardiol 2011; 58: 681-8
-
(2011)
J Am Coll Cardiol
, vol.58
, pp. 681-688
-
-
Herrera Sikloády, C.1
Deneke, T.2
Hocini, M.3
Lehrmann, H.4
Shin, D.-I.5
Miyazaki, S.6
-
7
-
-
79961204469
-
Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: Comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon
-
Gaita F, Leclercq JF, Schumacher B, Scaglione M, Toso E, Halimi F, et al. Incidence of silent cerebral thromboembolic lesions after atrial fibrillation ablation may change according to technology used: comparison of irrigated radiofrequency, multipolar nonirrigated catheter and cryoballoon. J Cardiovasc Electrophysiol 2011; 22: 961-8
-
(2011)
J Cardiovasc Electrophysiol
, vol.22
, pp. 961-968
-
-
Gaita, F.1
Leclercq, J.F.2
Schumacher, B.3
Scaglione, M.4
Toso, E.5
Halimi, F.6
-
8
-
-
84905654164
-
Safety and efficacy of multipolar pulmonary vein ablation catheter vs irrigated radiofrequency ablation for paroxysmal atrial fibrillation: A randomized multicentre trial
-
McCready J, Chow AW, Lowe MD, Segal OR, Ahsan S, de Bono J, et al. Safety and efficacy of multipolar pulmonary vein ablation catheter vs. irrigated radiofrequency ablation for paroxysmal atrial fibrillation: a randomized multicentre trial. Europace 2014; 16: 1145-53
-
(2014)
Europace
, vol.16
, pp. 1145-1153
-
-
McCready, J.1
Chow, A.W.2
Lowe, M.D.3
Segal, O.R.4
Ahsan, S.5
De Bono, J.6
-
9
-
-
84877282475
-
Dutycycled bipolar/unipolar radiofrequency ablation for symptomatic atrial fibrillation induces significant pulmonary vein narrowing at long-Term follow-up
-
CompierMG, LeongDP, MarsanNA, DelgadoV, Zeppenfeld K, Schalij MJ, et al. Dutycycled bipolar/unipolar radiofrequency ablation for symptomatic atrial fibrillation induces significant pulmonary vein narrowing at long-Term follow-up. Europace 2013; 15: 690-6
-
(2013)
Europace
, vol.15
, pp. 690-696
-
-
Compier, M.G.1
Leong, D.P.2
Marsan, N.A.3
Delgado, V.4
Zeppenfeld, K.5
Schalij, M.J.6
-
10
-
-
84897970587
-
Acute safety and efficacy of a novelmultipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation
-
Deneke T, Schade A, Müller P, Schmitt R, Christopoulos G, Krug J, et al. Acute safety and efficacy of a novelmultipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation. J Cardiovasc Electrophysiol 2014; 25: 339-45
-
(2014)
J Cardiovasc Electrophysiol
, vol.25
, pp. 339-345
-
-
Deneke, T.1
Schade, A.2
Müller, P.3
Schmitt, R.4
Christopoulos, G.5
Krug, J.6
-
11
-
-
84894517340
-
Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation
-
Shin D-I, Kirmanoglou K, Eickholt C, Schmidt J, Clasen L, Butzbach B, et al. Initial results of using a novel irrigated multielectrode mapping and ablation catheter for pulmonary vein isolation. Heart Rhythm 2014; 11: 375-83
-
(2014)
Heart Rhythm
, vol.11
, pp. 375-383
-
-
Shin, D.-I.1
Kirmanoglou, K.2
Eickholt, C.3
Schmidt, J.4
Clasen, L.5
Butzbach, B.6
-
12
-
-
84906972566
-
Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): A report on feasibility and efficacy
-
Zellerhoff S, Daly M, Lim HS, Denis A, Komatsu Y, Jesel L, et al. Pulmonary vein isolation using a circular, open irrigated mapping and ablation catheter (nMARQ): a report on feasibility and efficacy. Europace 2014; 16: 1296-303
-
(2014)
Europace
, vol.16
, pp. 1296-1303
-
-
Zellerhoff, S.1
Daly, M.2
Lim, H.S.3
Denis, A.4
Komatsu, Y.5
Jesel, L.6
-
13
-
-
84924419518
-
Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation
-
Rillig A, Lin T, Burchard A, Kamioka M, Heeger C, MakimotoHet al. Modified energy settings are mandatory to minimize oesophageal injury using the novel multipolar irrigated radiofrequency ablation catheter for pulmonary vein isolation. Europace 2015; 17: 396-402
-
(2015)
Europace
, vol.17
, pp. 396-402
-
-
Rillig, A.1
Lin, T.2
Burchard, A.3
Kamioka, M.4
Heeger, C.5
Makimoto, H.6
-
14
-
-
84875508668
-
2012 focused update of the ESC guidelines for the management of atrial fibrillation: An update of the 2010 ESC guidelines for the management of atrial fibrillation developed with the special contribution of the european heart rhythm association
-
Camm AJ, Lip GYH, De Caterina R, Savelieva I, Atar D, Hohnloser SH, et al. 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation developed with the special contribution of the European Heart Rhythm Association. Europace 2012; 14: 1385-413
-
(2012)
Europace
, vol.14
, pp. 1385-1413
-
-
Camm, A.J.1
Lip, G.Y.H.2
De Caterina, R.3
Savelieva, I.4
Atar, D.5
Hohnloser, S.H.6
-
15
-
-
78650176642
-
Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: Biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns
-
Kühne M, Suter Y, Altmann D, Ammann P, Schaer B, Osswald S, et al. Cryoballoon versus radiofrequency catheter ablation of paroxysmal atrial fibrillation: biomarkers of myocardial injury, recurrence rates, and pulmonary vein reconnection patterns. Heart Rhythm 2010; 7: 1770-6
-
(2010)
Heart Rhythm
, vol.7
, pp. 1770-1776
-
-
Kühne, M.1
Suter, Y.2
Altmann, D.3
Ammann, P.4
Schaer, B.5
Osswald, S.6
-
16
-
-
84875753938
-
Dabigatran vs warfarin for radiofrequency catheter ablation of atrial fibrillation
-
Kim J-S, She F, Jongnarangsin K, Chugh A, Latchamsetty R, Ghanbari H, et al. Dabigatran vs warfarin for radiofrequency catheter ablation of atrial fibrillation. Heart Rhythm 2013; 10: 483-9
-
(2013)
Heart Rhythm
, vol.10
, pp. 483-489
-
-
Kim, J.-S.1
She, F.2
Jongnarangsin, K.3
Chugh, A.4
Latchamsetty, R.5
Ghanbari, H.6
-
17
-
-
84878046350
-
The optimal range of international normalized ratio for radiofrequency catheter ablation of atrial fibrillation during therapeutic anticoagulation with warfarin
-
Kim J-S, Jongnarangsin K, Latchamsetty R, Chugh A, Ghanbari H, Crawford T, et al. The optimal range of international normalized ratio for radiofrequency catheter ablation of atrial fibrillation during therapeutic anticoagulation with warfarin. Circ Arrhythm Electrophysiol 2013; 6: 302-9
-
(2013)
Circ Arrhythm Electrophysiol
, vol.6
, pp. 302-309
-
-
Kim, J.-S.1
Jongnarangsin, K.2
Latchamsetty, R.3
Chugh, A.4
Ghanbari, H.5
Crawford, T.6
-
18
-
-
84891874394
-
Cryoballoon versus rf ablation in paroxysmal atrial fibrillation: Results from the German ablation registry
-
Schmidt M, Dorwarth U, Andresen D, Brachmann J, Kuck K-H, KunissMet al. Cryoballoon versus RF ablation in paroxysmal atrial fibrillation: results from the German Ablation Registry. J Cardiovasc Electrophysiol 2014; 25: 1-7
-
(2014)
J Cardiovasc Electrophysiol
, vol.25
, pp. 1-7
-
-
Schmidt, M.1
Dorwarth, U.2
Andresen, D.3
Brachmann, J.4
Kuck, K.-H.5
Kuniss, M.6
-
19
-
-
84864648442
-
Pulmonary vein isolation to treat paroxysmal atrial fibrillation: Conventional versus multi-electrode radiofrequency ablation
-
Beukema RJ, Elvan A, Smit JJJ, Delnoy PPHM, Misier ARR, Reddy V. Pulmonary vein isolation to treat paroxysmal atrial fibrillation: conventional versus multi-electrode radiofrequency ablation. J Interv Card Electrophysiol 2012; 34: 143-52
-
(2012)
J Interv Card Electrophysiol
, vol.34
, pp. 143-152
-
-
Beukema, R.J.1
Elvan, A.2
Smit, J.J.J.3
Delnoy, P.P.H.M.4
Misier, A.R.R.5
Reddy, V.6
-
20
-
-
84897037721
-
Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: Verification of intracardiac signals with a second circular mapping catheter
-
Rosso R, Halkin A, Michowitz Y, Belhassen B, Glick A, Viskin S. Radiofrequency ablation of paroxysmal atrial fibrillation with the new irrigated multipolar nMARQ ablation catheter: verification of intracardiac signals with a second circular mapping catheter. Heart Rhythm 2014; 11: 559-65
-
(2014)
Heart Rhythm
, vol.11
, pp. 559-565
-
-
Rosso, R.1
Halkin, A.2
Michowitz, Y.3
Belhassen, B.4
Glick, A.5
Viskin, S.6
-
21
-
-
84883011022
-
Pulmonary vein isolation using a visually guided laser balloon catheter: The first 200-patient multicenter clinical experience
-
Dukkipati SR, Kuck K-H, Neuzil P, Woollett I, Kautzner J, McElderry HT, et al. Pulmonary vein isolation using a visually guided laser balloon catheter: the first 200-patient multicenter clinical experience. Circ Arrhythm Electrophysiol 2013; 6: 467-72
-
(2013)
Circ Arrhythm Electrophysiol
, vol.6
, pp. 467-472
-
-
Dukkipati, S.R.1
Kuck, K.-H.2
Neuzil, P.3
Woollett, I.4
Kautzner, J.5
McElderry, H.T.6
-
22
-
-
84926410287
-
Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQTM): Feasibility, acute and short-Term efficacy, safety, and impact on postablation silent cerebral ischemia
-
ScaglioneM, Caponi D, Anselmino M, Clemente FD, Blandino A, Ferraris F, et al. Pulmonary vein isolation with a new multipolar irrigated radiofrequency ablation catheter (nMARQTM): feasibility, acute and short-Term efficacy, safety, and impact on postablation silent cerebral ischemia. J Cardiovasc Electrophysiol 2014; 25: 1299-305
-
(2014)
J Cardiovasc Electrophysiol
, vol.25
, pp. 1299-1305
-
-
Scaglione, M.1
Caponi, D.2
Anselmino, M.3
Clemente, F.D.4
Blandino, A.5
Ferraris, F.6
|