-
1
-
-
80052249350
-
How to treat stage D heart failure? When to implant left ventricular assist devices in the era of continuous flow pumps?
-
COI: 1:CAS:528:DC%2BC3MXht1Cjsb7J, PID: 21817817
-
Kinugawa K. How to treat stage D heart failure? When to implant left ventricular assist devices in the era of continuous flow pumps? Circ J. 2011;75(9):2038–45.
-
(2011)
Circ J
, vol.75
, Issue.9
, pp. 2038-2045
-
-
Kinugawa, K.1
-
2
-
-
84901193378
-
Sixth INTERMACS annual report: a 10,000-patient database
-
Kirklin JK, Naftel DC, Pagani FD, et al. Sixth INTERMACS annual report: a 10,000-patient database. J Heart Lung Transpl. 2014;33(6):555–64.
-
(2014)
J Heart Lung Transpl
, vol.33
, Issue.6
, pp. 555-564
-
-
Kirklin, J.K.1
Naftel, D.C.2
Pagani, F.D.3
-
3
-
-
84925446141
-
Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation
-
PID: 25381791
-
Imamura T, Kinugawa K, Fujino T, et al. Aortic insufficiency in patients with sustained left ventricular systolic dysfunction after axial flow assist device implantation. Circ J. 2015;79(1):104–11. doi:10.1253/circj.CJ-14-0944.
-
(2015)
Circ J
, vol.79
, Issue.1
, pp. 104-111
-
-
Imamura, T.1
Kinugawa, K.2
Fujino, T.3
-
4
-
-
84877271579
-
Magnitude and time course of changes induced by continuous-flow left ventricular assist device unloading in chronic heart failure: insights into cardiac recovery
-
PID: 23500219
-
Drakos SG, Wever-Pinzon O, Selzman CH, et al. Magnitude and time course of changes induced by continuous-flow left ventricular assist device unloading in chronic heart failure: insights into cardiac recovery. J Am Coll Cardiol. 2013;61(19):1985–94.
-
(2013)
J Am Coll Cardiol
, vol.61
, Issue.19
, pp. 1985-1994
-
-
Drakos, S.G.1
Wever-Pinzon, O.2
Selzman, C.H.3
-
5
-
-
84897111173
-
Preoperative beta-blocker treatment is a key for deciding left ventricular assist device implantation strategy as a bridge to recovery
-
COI: 1:CAS:528:DC%2BC2cXks1OgsLs%3D, PID: 24337665
-
Imamura T, Kinugawa K, Hatano M, et al. Preoperative beta-blocker treatment is a key for deciding left ventricular assist device implantation strategy as a bridge to recovery. J Artif Organs. 2014;17(1):23–32.
-
(2014)
J Artif Organs.
, vol.17
, Issue.1
, pp. 23-32
-
-
Imamura, T.1
Kinugawa, K.2
Hatano, M.3
-
6
-
-
0025264898
-
Neuronal mapping of the heart with 6-[18F]fluorometaraminol
-
COI: 1:CAS:528:DyaK3cXhtFGhs7s%3D, PID: 2308146
-
Wieland DM, Rosenspire KC, Hutchins GD, et al. Neuronal mapping of the heart with 6-[18F]fluorometaraminol. J Med Chem. 1990;33(3):956–64.
-
(1990)
J Med Chem
, vol.33
, Issue.3
, pp. 956-964
-
-
Wieland, D.M.1
Rosenspire, K.C.2
Hutchins, G.D.3
-
7
-
-
0028893627
-
Uptake mechanisms of meta-[123I]iodobenzylguanidine in isolated rat heart
-
COI: 1:CAS:528:DyaK2MXkslGisbY%3D, PID: 7735158
-
Degrado TR, Zalutsky MR, Vaidyanathan G. Uptake mechanisms of meta-[123I]iodobenzylguanidine in isolated rat heart. Nucl Med Biol. 1995;22(1):1–12.
-
(1995)
Nucl Med Biol
, vol.22
, Issue.1
, pp. 1-12
-
-
Degrado, T.R.1
Zalutsky, M.R.2
Vaidyanathan, G.3
-
8
-
-
79954438987
-
Determination of the survival rate in patients with congestive heart failure stratified by (1)(2)(3)I-MIBG imaging: a meta-analysis from the studies performed in Japan
-
PID: 21210256
-
Kuwabara Y, Tamaki N, Nakata T, Yamashina S, Yamazaki J. Determination of the survival rate in patients with congestive heart failure stratified by (1)(2)(3)I-MIBG imaging: a meta-analysis from the studies performed in Japan. Ann Nucl Med. 2011;25(2):101–7.
-
(2011)
Ann Nucl Med
, vol.25
, Issue.2
, pp. 101-107
-
-
Kuwabara, Y.1
Tamaki, N.2
Nakata, T.3
Yamashina, S.4
Yamazaki, J.5
-
9
-
-
84862936669
-
Risk stratification in heart failure using (1)(2)(3)I-MIBG
-
PID: 21969356
-
Currie GM, Iqbal B, Wheat JM, et al. Risk stratification in heart failure using (1)(2)(3)I-MIBG. J Nucl Med Technol. 2011;39(4):295–301.
-
(2011)
J Nucl Med Technol.
, vol.39
, Issue.4
, pp. 295-301
-
-
Currie, G.M.1
Iqbal, B.2
Wheat, J.M.3
-
10
-
-
84881238952
-
Cardiac I123-MIBG correlates better than ejection fraction with symptoms severity in systolic heart failure
-
PID: 23917506
-
Miranda SM, Moscavitch SD, Carestiato LR, et al. Cardiac I123-MIBG correlates better than ejection fraction with symptoms severity in systolic heart failure. Arq Bras Cardiol. 2013;101(1):4–8.
-
(2013)
Arq Bras Cardiol
, vol.101
, Issue.1
, pp. 4-8
-
-
Miranda, S.M.1
Moscavitch, S.D.2
Carestiato, L.R.3
-
11
-
-
77951222477
-
Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure. Results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study
-
PID: 20188504
-
Jacobson AF, Senior R, Cerqueira MD, et al. Myocardial iodine-123 meta-iodobenzylguanidine imaging and cardiac events in heart failure. Results of the prospective ADMIRE-HF (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) study. J Am Coll Cardiol. 2010;55(20):2212–21.
-
(2010)
J Am Coll Cardiol
, vol.55
, Issue.20
, pp. 2212-2221
-
-
Jacobson, A.F.1
Senior, R.2
Cerqueira, M.D.3
-
12
-
-
58549097907
-
Cardiac iodine-123 metaiodobenzylguanidine imaging predicts sudden cardiac death independently of left ventricular ejection fraction in patients with chronic heart failure and left ventricular systolic dysfunction: results from a comparative study with signal-averaged electrocardiogram, heart rate variability, and QT dispersion
-
COI: 1:CAS:528:DC%2BD1MXhtlShsbc%3D, PID: 19179201
-
Tamaki S, Yamada T, Okuyama Y, et al. Cardiac iodine-123 metaiodobenzylguanidine imaging predicts sudden cardiac death independently of left ventricular ejection fraction in patients with chronic heart failure and left ventricular systolic dysfunction: results from a comparative study with signal-averaged electrocardiogram, heart rate variability, and QT dispersion. J Am Coll Cardiol. 2009;53(5):426–35.
-
(2009)
J Am Coll Cardiol
, vol.53
, Issue.5
, pp. 426-435
-
-
Tamaki, S.1
Yamada, T.2
Okuyama, Y.3
-
13
-
-
84888321695
-
Iodine-123-metaiodobenzylguanidine scintigraphy in risk stratification of sudden death in heart failure
-
PID: 23731734
-
Martins da Silva MI, Vidigal Ferreira MJ, Morao Moreira AP, Martins da Silva MI. Iodine-123-metaiodobenzylguanidine scintigraphy in risk stratification of sudden death in heart failure. Rev Port Cardiol. 2013;32(6):509–16.
-
(2013)
Rev Port Cardiol
, vol.32
, Issue.6
, pp. 509-516
-
-
Martins da Silva, M.I.1
Vidigal Ferreira, M.J.2
Morao Moreira, A.P.3
Martins da Silva, M.I.4
-
14
-
-
84880008355
-
A pooled analysis of multicenter cohort studies of (123)I-mIBG imaging of sympathetic innervation for assessment of long-term prognosis in heart failure
-
PID: 23845574
-
Nakata T, Nakajima K, Yamashina S, et al. A pooled analysis of multicenter cohort studies of (123)I-mIBG imaging of sympathetic innervation for assessment of long-term prognosis in heart failure. JACC Cardiovasc Imaging. 2013;6(7):772–84.
-
(2013)
JACC Cardiovasc Imaging.
, vol.6
, Issue.7
, pp. 772-784
-
-
Nakata, T.1
Nakajima, K.2
Yamashina, S.3
-
15
-
-
84869127326
-
Influence of ejection fraction on the prognostic value of sympathetic innervation imaging with iodine-123 MIBG in heart failure
-
PID: 23153914
-
Shah AM, Bourgoun M, Narula J, Jacobson AF, Solomon SD. Influence of ejection fraction on the prognostic value of sympathetic innervation imaging with iodine-123 MIBG in heart failure. JACC Cardiovasc Imaging. 2012;5(11):1139–46.
-
(2012)
JACC Cardiovasc Imaging.
, vol.5
, Issue.11
, pp. 1139-1146
-
-
Shah, A.M.1
Bourgoun, M.2
Narula, J.3
Jacobson, A.F.4
Solomon, S.D.5
-
16
-
-
0037439014
-
Comparison of the prognostic value of cardiac iodine-123 metaiodobenzylguanidine imaging and heart rate variability in patients with chronic heart failure: a prospective study
-
PID: 12535815
-
Yamada T, Shimonagata T, Fukunami M, et al. Comparison of the prognostic value of cardiac iodine-123 metaiodobenzylguanidine imaging and heart rate variability in patients with chronic heart failure: a prospective study. J Am Coll Cardiol. 2003;41(2):231–8.
-
(2003)
J Am Coll Cardiol
, vol.41
, Issue.2
, pp. 231-238
-
-
Yamada, T.1
Shimonagata, T.2
Fukunami, M.3
-
17
-
-
80052308476
-
Long-term prognostic stratification by a combination of (123)I-metaiodobenzylguanidine scintigraphy and ejection fraction in dilated cardiomyopathy
-
PID: 21461599
-
Momose M, Okayama D, Nagamatsu H, Kondo C, Hagiwara N, Sakai S. Long-term prognostic stratification by a combination of (123)I-metaiodobenzylguanidine scintigraphy and ejection fraction in dilated cardiomyopathy. Ann Nucl Med. 2011;25(6):419–24.
-
(2011)
Ann Nucl Med
, vol.25
, Issue.6
, pp. 419-424
-
-
Momose, M.1
Okayama, D.2
Nagamatsu, H.3
Kondo, C.4
Hagiwara, N.5
Sakai, S.6
-
18
-
-
0033101759
-
Cardiac metaiodobenzylguanidine uptake in patients with moderate chronic heart failure: relationship with peak oxygen uptake and prognosis
-
COI: 1:STN:280:DyaK1M7nvVGlsQ%3D%3D, PID: 10080478
-
Cohen-Solal A, Esanu Y, Logeart D, et al. Cardiac metaiodobenzylguanidine uptake in patients with moderate chronic heart failure: relationship with peak oxygen uptake and prognosis. J Am Coll Cardiol. 1999;33(3):759–66.
-
(1999)
J Am Coll Cardiol
, vol.33
, Issue.3
, pp. 759-766
-
-
Cohen-Solal, A.1
Esanu, Y.2
Logeart, D.3
-
19
-
-
79960611604
-
Cardiac sympathetic reserve and response to cardiac resynchronization therapy
-
PID: 21421772
-
Cha YM, Chareonthaitawee P, Dong YX, et al. Cardiac sympathetic reserve and response to cardiac resynchronization therapy. Circ Heart Fail. 2011;4(3):339–44.
-
(2011)
Circ Heart Fail.
, vol.4
, Issue.3
, pp. 339-344
-
-
Cha, Y.M.1
Chareonthaitawee, P.2
Dong, Y.X.3
-
20
-
-
0035095070
-
Evaluation of beta-blocker therapy in patients with dilated cardiomyopathy—clinical meaning of iodine 123-metaiodobenzylguanidine myocardial single-photon emission computed tomography
-
COI: 1:CAS:528:DC%2BD3MXjtFygsbc%3D, PID: 11275933
-
Yamazaki J, Muto H, Kabano T, Yamashina S, Nanjo S, Inoue A. Evaluation of beta-blocker therapy in patients with dilated cardiomyopathy—clinical meaning of iodine 123-metaiodobenzylguanidine myocardial single-photon emission computed tomography. Am Heart J. 2001;141(4):645–52.
-
(2001)
Am Heart J
, vol.141
, Issue.4
, pp. 645-652
-
-
Yamazaki, J.1
Muto, H.2
Kabano, T.3
Yamashina, S.4
Nanjo, S.5
Inoue, A.6
-
21
-
-
73649109607
-
Myocardial sympathetic innervation and long-term left ventricular mechanical unloading
-
PID: 20129533
-
Drakos SG, Athanasoulis T, Malliaras KG, et al. Myocardial sympathetic innervation and long-term left ventricular mechanical unloading. JACC Cardiovasc Imaging. 2010;3(1):64–70.
-
(2010)
JACC Cardiovasc Imaging.
, vol.3
, Issue.1
, pp. 64-70
-
-
Drakos, S.G.1
Athanasoulis, T.2
Malliaras, K.G.3
-
22
-
-
84883184086
-
The effect of long-term left ventricular assist device support on myocardial sympathetic activity in patients with non-ischaemic dilated cardiomyopathy
-
COI: 1:CAS:528:DC%2BC3sXht1yrs77K, PID: 23610136
-
George RS, Birks EJ, Cheetham A, et al. The effect of long-term left ventricular assist device support on myocardial sympathetic activity in patients with non-ischaemic dilated cardiomyopathy. Eur J Heart Fail. 2013;15(9):1035–43.
-
(2013)
Eur J Heart Fail
, vol.15
, Issue.9
, pp. 1035-1043
-
-
George, R.S.1
Birks, E.J.2
Cheetham, A.3
-
23
-
-
84954117629
-
Opening of aortic valve during exercise is key to preventing development of aortic insufficiency during ventricular assist device treatment
-
PID: 25955152
-
Imamura T, Kinugawa K, Nitta D, Hatano M, Ono M. Opening of aortic valve during exercise is key to preventing development of aortic insufficiency during ventricular assist device treatment. ASAIO J. 2015. doi:10.1097/MAT.0000000000000247.
-
(2015)
ASAIO J
-
-
Imamura, T.1
Kinugawa, K.2
Nitta, D.3
Hatano, M.4
Ono, M.5
-
24
-
-
83555170951
-
Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling
-
PID: 21765125
-
Kato TS, Chokshi A, Singh P, et al. Effects of continuous-flow versus pulsatile-flow left ventricular assist devices on myocardial unloading and remodeling. Circ Heart Fail. 2011;4(5):546–53.
-
(2011)
Circ Heart Fail.
, vol.4
, Issue.5
, pp. 546-553
-
-
Kato, T.S.1
Chokshi, A.2
Singh, P.3
-
25
-
-
24644466420
-
Myocardial recovery using ventricular assist devices: prevalence, clinical characteristics, and outcomes
-
PID: 16159839
-
Simon MA, Kormos RL, Murali S, et al. Myocardial recovery using ventricular assist devices: prevalence, clinical characteristics, and outcomes. Circulation. 2005;112(9 Suppl):I32–6.
-
(2005)
Circulation
, vol.112
, pp. I32-I36
-
-
Simon, M.A.1
Kormos, R.L.2
Murali, S.3
-
26
-
-
84901271321
-
Post-approval study of a highly pulsed, low-shear-rate, continuous-flow, left ventricular assist device, EVAHEART: a Japanese multicenter study using J-MACS
-
Saito S, Yamazaki K, Nishinaka T, et al. Post-approval study of a highly pulsed, low-shear-rate, continuous-flow, left ventricular assist device, EVAHEART: a Japanese multicenter study using J-MACS. J Heart Lung Transpl. 2014;33(6):599–608.
-
(2014)
J Heart Lung Transpl
, vol.33
, Issue.6
, pp. 599-608
-
-
Saito, S.1
Yamazaki, K.2
Nishinaka, T.3
-
27
-
-
77952550509
-
Cardiac fibrosis and cellular hypertrophy decrease the degree of reverse remodeling and improvement in cardiac function during left ventricular assist
-
Saito S, Matsumiya G, Sakaguchi T, et al. Cardiac fibrosis and cellular hypertrophy decrease the degree of reverse remodeling and improvement in cardiac function during left ventricular assist. J Heart Lung Transpl. 2010;29(6):672–9.
-
(2010)
J Heart Lung Transpl
, vol.29
, Issue.6
, pp. 672-679
-
-
Saito, S.1
Matsumiya, G.2
Sakaguchi, T.3
-
28
-
-
62149101431
-
How to use myocardial 123I-MIBG scintigraphy in chronic heart failure
-
PID: 18989666
-
Agostini D, Carrio I, Verberne HJ. How to use myocardial 123I-MIBG scintigraphy in chronic heart failure. Eur J Nucl Med Mol Imaging. 2009;36(4):555–9.
-
(2009)
Eur J Nucl Med Mol Imaging
, vol.36
, Issue.4
, pp. 555-559
-
-
Agostini, D.1
Carrio, I.2
Verberne, H.J.3
-
29
-
-
84925506169
-
Lower rotation speed stimulates sympathetic activation during continuous-flow left ventricular assist device treatment
-
PID: 25337982
-
Imamura T, Kinugawa K, Nitta D, et al. Lower rotation speed stimulates sympathetic activation during continuous-flow left ventricular assist device treatment. J Artif Organs. 2015;18(1):20–6.
-
(2015)
J Artif Organs.
, vol.18
, Issue.1
, pp. 20-26
-
-
Imamura, T.1
Kinugawa, K.2
Nitta, D.3
|