메뉴 건너뛰기




Volumn 29, Issue 3, 2016, Pages 299-302

Carotid Artery Applanation Tonometry Does Not Cause Significant Baroreceptor Activation

Author keywords

applanation tonometry; baroreceptor activation; baroreflex; blood pressure; carotid artery; hypertension; pulse wave velocity

Indexed keywords

ARTERIAL PRESSURE; ARTICLE; BLOOD PRESSURE; BRADYCARDIA; CAROTID ARTERY; CLINICAL ARTICLE; DIASTOLIC BLOOD PRESSURE; FEMORAL ARTERY; HEART RATE; HEART RATE VARIABILITY; HEMODYNAMICS; HUMAN; HYPOTENSION; PRESSORECEPTOR; PRIORITY JOURNAL; PULSE WAVE; TONOMETRY; HYPERTENSION; MANOMETRY; PATHOPHYSIOLOGY; PHYSIOLOGY; PRESSORECEPTOR REFLEX; PROCEDURES;

EID: 84960394961     PISSN: 08957061     EISSN: 19417225     Source Type: Journal    
DOI: 10.1093/ajh/hpv064     Document Type: Article
Times cited : (6)

References (11)
  • 4
    • 84919663175 scopus 로고    scopus 로고
    • Baroreceptor stimulation for resistant hypertension: First implantation in France and literature review
    • Courand PY, Feugier P, Workineh S, Harbaoui B, Bricca G, Lantelme P. Baroreceptor stimulation for resistant hypertension: first implantation in France and literature review. Arch Cardiovasc Dis 2014; 107:690-696.
    • (2014) Arch Cardiovasc Dis , vol.107 , pp. 690-696
    • Courand, P.Y.1    Feugier, P.2    Workineh, S.3    Harbaoui, B.4    Bricca, G.5    Lantelme, P.6
  • 5
    • 0021949958 scopus 로고
    • Carotid sinus massage. Its diagnostic and therapeutic value in arrhythmias
    • Schweitzer P, Teichholz LE. Carotid sinus massage. Its diagnostic and therapeutic value in arrhythmias. Am J Med 1985; 78:645-654.
    • (1985) Am J Med , vol.78 , pp. 645-654
    • Schweitzer, P.1    Teichholz, L.E.2
  • 6
    • 34347203346 scopus 로고
    • Apparatus and method for measurement of digital pressure applied to carotid sinus for causing carotid sinus syndrome
    • Takino M, Takino Y, Sugahara K. Apparatus and method for measurement of digital pressure applied to carotid sinus for causing carotid sinus syndrome. Acta Neuroveg (Wien) 1964; 26:93-103.
    • (1964) Acta Neuroveg (Wien) , vol.26 , pp. 93-103
    • Takino, M.1    Takino, Y.2    Sugahara, K.3
  • 7
    • 13144277531 scopus 로고    scopus 로고
    • Evaluation of carotid-femoral pulse wave velocity: Influence of timing algorithm and heart rate
    • Millasseau SC, Stewart AD, Patel SJ, Redwood SR, Chowienczyk PJ. Evaluation of carotid-femoral pulse wave velocity: influence of timing algorithm and heart rate. Hypertension 2005; 45:222-226.
    • (2005) Hypertension , vol.45 , pp. 222-226
    • Millasseau, S.C.1    Stewart, A.D.2    Patel, S.J.3    Redwood, S.R.4    Chowienczyk, P.J.5
  • 8
    • 0036278324 scopus 로고    scopus 로고
    • Heart rate: An important confounder of pulse wave velocity assessment
    • Lantelme P, Mestre C, Lievre M, Gressard A, Milon H. Heart rate: an important confounder of pulse wave velocity assessment. Hypertension 2002; 39:1083-1087.
    • (2002) Hypertension , vol.39 , pp. 1083-1087
    • Lantelme, P.1    Mestre, C.2    Lievre, M.3    Gressard, A.4    Milon, H.5
  • 11
    • 0002220170 scopus 로고
    • Photoelectric measurement of blood pressure, volume and flow in the finger
    • In Albert A, Vogt W, Hellig W (eds) International Federation for Medical and Biological Engineering: Dresden
    • Pez J. Photoelectric measurement of blood pressure, volume and flow in the finger. In Albert A, Vogt W, Hellig W (eds), Digest of the 10th International Conference on Medical and Biological Engineering. International Federation for Medical and Biological Engineering: Dresden, 1973, p. 104.
    • (1973) Digest of the 10th International Conference on Medical and Biological Engineering , pp. 104
    • Pez, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.