-
1
-
-
84960191786
-
D7929-14: standard guide for selection of passive techniques for sampling groundwater monitoring wells
-
ASTM International, West Conshohocken, PA
-
ASTM D7929-14: standard guide for selection of passive techniques for sampling groundwater monitoring wells. ASTM Volume 04.09 Soil and Rock (II) 2014, ASTM International, West Conshohocken, PA.
-
(2014)
ASTM Volume 04.09 Soil and Rock (II)
-
-
-
2
-
-
16844375153
-
Time-integrated monitoring of polycyclic aromatic hydrocarbons (PAHs) in groundwater using the Ceramic Dosimeter passive sampling device
-
Bopp S., Weiß H., Schirmer K. Time-integrated monitoring of polycyclic aromatic hydrocarbons (PAHs) in groundwater using the Ceramic Dosimeter passive sampling device. J. Chromatogr. A 2005, 1072(1):137-147.
-
(2005)
J. Chromatogr. A
, vol.1072
, Issue.1
, pp. 137-147
-
-
Bopp, S.1
Weiß, H.2
Schirmer, K.3
-
4
-
-
0002808644
-
Collection and analysis of trace organic vapour pollutants in ambient atmospheres: the performace of a Tenax-GC adsorbent tube
-
Brown R., Purnell C. Collection and analysis of trace organic vapour pollutants in ambient atmospheres: the performace of a Tenax-GC adsorbent tube. J. Chromatogr. A 1979, 178(1):79-90.
-
(1979)
J. Chromatogr. A
, vol.178
, Issue.1
, pp. 79-90
-
-
Brown, R.1
Purnell, C.2
-
5
-
-
84960107216
-
-
(March 9, 2015).
-
California Environmental Protection Agency, GeoTracker. (March 9, 2015). http://geotracker.waterboards.ca.gov.
-
GeoTracker
-
-
-
6
-
-
84892531727
-
Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods
-
Coes A.L., Paretti N.V., Foreman W.T., Iverson J.L., Alvarez D.A. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods. Sci. Total Environ. 2014, 473:731-741.
-
(2014)
Sci. Total Environ.
, vol.473
, pp. 731-741
-
-
Coes, A.L.1
Paretti, N.V.2
Foreman, W.T.3
Iverson, J.L.4
Alvarez, D.A.5
-
7
-
-
84960095322
-
-
(July 17, 2015).
-
FedEx, 2015. Service Guide. (July 17, 2015). http://www.fedex.com/serviceguide.
-
(2015)
Service Guide
-
-
-
9
-
-
0023306256
-
Stability of hydrocarbon samples on solid-phase extraction columns
-
Green D.R., Le Pape D. Stability of hydrocarbon samples on solid-phase extraction columns. Anal. Chem. 1987, 59(5):699-703.
-
(1987)
Anal. Chem.
, vol.59
, Issue.5
, pp. 699-703
-
-
Green, D.R.1
Le Pape, D.2
-
10
-
-
0022826868
-
Determination of chlorinated hydrocarbons in coastal waters using a moored in situ sampler and transplanted live mussels
-
Green D.R., Stull J.K., Heesen T.C. Determination of chlorinated hydrocarbons in coastal waters using a moored in situ sampler and transplanted live mussels. Mar. Pollut. Bull. 1986, 17(7):324-329.
-
(1986)
Mar. Pollut. Bull.
, vol.17
, Issue.7
, pp. 324-329
-
-
Green, D.R.1
Stull, J.K.2
Heesen, T.C.3
-
11
-
-
84960191788
-
Cost-effective, ultra-sensitive groundwater monitoring for site remediation and management
-
December 23, 2015
-
Halden R.U., Roll I. Cost-effective, ultra-sensitive groundwater monitoring for site remediation and management. Report Number ER-201122 2015, United States Department of Defense, Environmental Security Technology Certification Program (ESTCP), (https://www.serdp-estcp.org/Program-Areas/Environmental-Restoration/Contaminated-Groundwater/Monitoring/ER-201122, December 23, 2015).
-
(2015)
Report Number ER-201122
-
-
Halden, R.U.1
Roll, I.2
-
12
-
-
0025310273
-
Semipermeable membrane devices containing model lipid: a new approach to monitoring the bioavaiiability of lipophilic contaminants and estimating their bioconcentration potential
-
Huckins J.N., Tubergen M.W., Manuweera G.K. Semipermeable membrane devices containing model lipid: a new approach to monitoring the bioavaiiability of lipophilic contaminants and estimating their bioconcentration potential. Chemosphere 1990, 20(5):533-552.
-
(1990)
Chemosphere
, vol.20
, Issue.5
, pp. 533-552
-
-
Huckins, J.N.1
Tubergen, M.W.2
Manuweera, G.K.3
-
13
-
-
0033230575
-
Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water
-
Huckins J.N., Petty J.D., Orazio C.E., Lebo J.A., Clark R.C., Gibson V.L., Gala W.R., Echols K.R. Determination of uptake kinetics (sampling rates) by lipid-containing semipermeable membrane devices (SPMDs) for polycyclic aromatic hydrocarbons (PAHs) in water. Environ. Sci. Technol. 1999, 33(21):3918-3923.
-
(1999)
Environ. Sci. Technol.
, vol.33
, Issue.21
, pp. 3918-3923
-
-
Huckins, J.N.1
Petty, J.D.2
Orazio, C.E.3
Lebo, J.A.4
Clark, R.C.5
Gibson, V.L.6
Gala, W.R.7
Echols, K.R.8
-
14
-
-
0036140511
-
Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices
-
Huckins J.N., Petty J.D., Lebo J.A., Almeida F.V., Booij K., Alvarez D.A., Cranor W.L., Clark R.C., Mogensen B.B. Development of the permeability/performance reference compound approach for in situ calibration of semipermeable membrane devices. Environ. Sci. Technol. 2002, 36(1):85-91.
-
(2002)
Environ. Sci. Technol.
, vol.36
, Issue.1
, pp. 85-91
-
-
Huckins, J.N.1
Petty, J.D.2
Lebo, J.A.3
Almeida, F.V.4
Booij, K.5
Alvarez, D.A.6
Cranor, W.L.7
Clark, R.C.8
Mogensen, B.B.9
-
15
-
-
77957917911
-
Determination of Cr (III) and Cr (VI) at sub-ppb levels in water with solid-phase extraction/metal furnace atomic absorption spectrometry
-
Inui T., Fujita K., Kitano M., Nakamura T. Determination of Cr (III) and Cr (VI) at sub-ppb levels in water with solid-phase extraction/metal furnace atomic absorption spectrometry. Anal. Sci. 2010, 26(10):1093-1098.
-
(2010)
Anal. Sci.
, vol.26
, Issue.10
, pp. 1093-1098
-
-
Inui, T.1
Fujita, K.2
Kitano, M.3
Nakamura, T.4
-
17
-
-
84892968913
-
Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water
-
Jacquet R., Miege C., Smedes F., Tixier C., Tronczynski J., Togola A., Berho C., Valor I., Llorca J., Barillon B., Marchand P., Coquery M. Comparison of five integrative samplers in laboratory for the monitoring of indicator and dioxin-like polychlorinated biphenyls in water. Chemosphere 2014, 98:18-27.
-
(2014)
Chemosphere
, vol.98
, pp. 18-27
-
-
Jacquet, R.1
Miege, C.2
Smedes, F.3
Tixier, C.4
Tronczynski, J.5
Togola, A.6
Berho, C.7
Valor, I.8
Llorca, J.9
Barillon, B.10
Marchand, P.11
Coquery, M.12
-
18
-
-
0343729887
-
Passive sampling for long-term monitoring of organic pollutants in water
-
Kot A., Zabiegała B., Namieśnik J. Passive sampling for long-term monitoring of organic pollutants in water. TrAC Trends Anal. Chem. 2000, 19(7):446-459.
-
(2000)
TrAC Trends Anal. Chem.
, vol.19
, Issue.7
, pp. 446-459
-
-
Kot, A.1
Zabiegała, B.2
Namieśnik, J.3
-
19
-
-
67649640010
-
Constantly stirred sorbent and continuous flow integrative sampler - new integrative samplers for the time weighted average water monitoring
-
Llorca J., Gutierrez C., Capilla E., Tortajada R., Sanjuan L., Fuentes A., Valor I. Constantly stirred sorbent and continuous flow integrative sampler - new integrative samplers for the time weighted average water monitoring. J. Chromatogr. A 2009, 1216:5783-5792.
-
(2009)
J. Chromatogr. A
, vol.1216
, pp. 5783-5792
-
-
Llorca, J.1
Gutierrez, C.2
Capilla, E.3
Tortajada, R.4
Sanjuan, L.5
Fuentes, A.6
Valor, I.7
-
20
-
-
13844271981
-
Passive sampling and/or extraction techniques in environmental analysis: a review
-
Namieśnik J., Zabiegała B., Kot-Wasik A., Partyka M., Wasik A. Passive sampling and/or extraction techniques in environmental analysis: a review. Anal. Bioanal. Chem. 2005, 381(2):279-301.
-
(2005)
Anal. Bioanal. Chem.
, vol.381
, Issue.2
, pp. 279-301
-
-
Namieśnik, J.1
Zabiegała, B.2
Kot-Wasik, A.3
Partyka, M.4
Wasik, A.5
-
21
-
-
84960121358
-
Water levels - NOAA tides and currents
-
(July 13, 2015).
-
National Oceanic and Atmospheric Administration, Water levels - NOAA tides and currents. (July 13, 2015). http://tidesandcurrents.noaa.gov/waterlevels.html?id=9410170.
-
-
-
-
22
-
-
0021428838
-
A syringe and cartridge method for down-hole sampling for trace organics in ground Water
-
Pankow J.F., Isabelle L.M., Hewetson J.P., Cherry J.A. A syringe and cartridge method for down-hole sampling for trace organics in ground Water. Ground Water 1984, 22(3):330-339.
-
(1984)
Ground Water
, vol.22
, Issue.3
, pp. 330-339
-
-
Pankow, J.F.1
Isabelle, L.M.2
Hewetson, J.P.3
Cherry, J.A.4
-
23
-
-
84869867265
-
The effect of bottle fill rate and pour technique on the recovery of volatile organics
-
Parker L., Britt S. The effect of bottle fill rate and pour technique on the recovery of volatile organics. Ground Water Monit. R. 2012, 32(4):78-86.
-
(2012)
Ground Water Monit. R.
, vol.32
, Issue.4
, pp. 78-86
-
-
Parker, L.1
Britt, S.2
-
24
-
-
60449113635
-
Sampling and preconcentration techniques for determination of volatile organic compounds in air samples
-
Ras M.R., Borrull F., Marcé R.M. Sampling and preconcentration techniques for determination of volatile organic compounds in air samples. TrAC Trends Anal. Chem. 2009, 28(3):347-361.
-
(2009)
TrAC Trends Anal. Chem.
, vol.28
, Issue.3
, pp. 347-361
-
-
Ras, M.R.1
Borrull, F.2
Marcé, R.M.3
-
25
-
-
84959321782
-
Critical review of factors governing data quality of integrative samplers employed in environmental water monitoring
-
Roll I.B., Halden R.U. Critical review of factors governing data quality of integrative samplers employed in environmental water monitoring. Water Res. 2016, 94:200-207.
-
(2016)
Water Res.
, vol.94
, pp. 200-207
-
-
Roll, I.B.1
Halden, R.U.2
-
26
-
-
84923025550
-
Indoor air condensate as a novel matrix for monitoring inhalable organic contaminants
-
Roll I.B., Halden R.U., Pycke B.F.G. Indoor air condensate as a novel matrix for monitoring inhalable organic contaminants. J. Hazard. Mater. 2015, 288(1):89-96.
-
(2015)
J. Hazard. Mater.
, vol.288
, Issue.1
, pp. 89-96
-
-
Roll, I.B.1
Halden, R.U.2
Pycke, B.F.G.3
-
27
-
-
0016827684
-
Analysis of air pollutants using sampling tubes and gas chromatography
-
Russell J.W. Analysis of air pollutants using sampling tubes and gas chromatography. Environ. Sci. Technol. 1975, 9(13):1175-1178.
-
(1975)
Environ. Sci. Technol.
, vol.9
, Issue.13
, pp. 1175-1178
-
-
Russell, J.W.1
-
28
-
-
84900537150
-
New device for time-averaged measurement of volatile organic compounds (VOCs)
-
Sánchez N.S., Alarcón S.T., Santonja R.J., Llorca-Pórcel J. New device for time-averaged measurement of volatile organic compounds (VOCs). Sci. Total Environ. 2014, 485-486:720-725.
-
(2014)
Sci. Total Environ.
, vol.485-486
, pp. 720-725
-
-
Sánchez, N.S.1
Alarcón, S.T.2
Santonja, R.J.3
Llorca-Pórcel, J.4
-
29
-
-
84977910156
-
New device for continuous measurement of trihalomethanes (TRIADEC)
-
Sánchez N.S., Alarcón S.T., Santonja R.J., Llorca-Pórcel J. New device for continuous measurement of trihalomethanes (TRIADEC). J. Environ. Anal. Chem. 2014, 1(2):110.
-
(2014)
J. Environ. Anal. Chem.
, vol.1
, Issue.2
, pp. 110
-
-
Sánchez, N.S.1
Alarcón, S.T.2
Santonja, R.J.3
Llorca-Pórcel, J.4
-
30
-
-
39749100759
-
Passive sampling in environmental analysis
-
Seethapathy S., Górecki T., Li X. Passive sampling in environmental analysis. J. Chromatogr. A 2008, 1184(1-2):234-253.
-
(2008)
J. Chromatogr. A
, vol.1184
, Issue.1-2
, pp. 234-253
-
-
Seethapathy, S.1
Górecki, T.2
Li, X.3
-
31
-
-
0011283536
-
Desiccation effects on stability of pesticides stored on solid-phase extraction disks
-
Senseman S.A., Lavy T.L., Mattice J.D. Desiccation effects on stability of pesticides stored on solid-phase extraction disks. Anal. Chem. 1995, 67(17):3064-3068.
-
(1995)
Anal. Chem.
, vol.67
, Issue.17
, pp. 3064-3068
-
-
Senseman, S.A.1
Lavy, T.L.2
Mattice, J.D.3
-
32
-
-
64349122727
-
Time integrative passive sampling: how well do Chemcatchers integrate fluctuating pollutant concentrations?
-
Shaw M., Mueller J.F. Time integrative passive sampling: how well do Chemcatchers integrate fluctuating pollutant concentrations?. Environ. Sci. Technol. 2009, 43(5):1443-1448.
-
(2009)
Environ. Sci. Technol.
, vol.43
, Issue.5
, pp. 1443-1448
-
-
Shaw, M.1
Mueller, J.F.2
-
33
-
-
57849092808
-
Techniques for quantitatively evaluating aquatic passive sampling devices
-
Elsevier, Amsterdam, The Netherlands, R. Greenwood, G. Mills, B. Vrana (Eds.)
-
Stephens B.S., Müller J.F. Techniques for quantitatively evaluating aquatic passive sampling devices. Passive Sampling Techniques in Environmental Monitoring 2007, 329-346. Elsevier, Amsterdam, The Netherlands. R. Greenwood, G. Mills, B. Vrana (Eds.).
-
(2007)
Passive Sampling Techniques in Environmental Monitoring
, pp. 329-346
-
-
Stephens, B.S.1
Müller, J.F.2
-
34
-
-
84959236803
-
Active sampling device for determining pollutants in surface and pore water - the in situ sampler for biphasic water monitoring
-
(Article 21886)
-
Supowit S.D., Roll I.B., Dang V.D., Kroll K.J., Denslow N.D., Halden R.U. Active sampling device for determining pollutants in surface and pore water - the in situ sampler for biphasic water monitoring. Sci. Rep. 2016, 6. (Article 21886). 10.1038/srep21886.
-
(2016)
Sci. Rep.
, vol.6
-
-
Supowit, S.D.1
Roll, I.B.2
Dang, V.D.3
Kroll, K.J.4
Denslow, N.D.5
Halden, R.U.6
-
35
-
-
0002057619
-
Laboratory and field testing on an Infiltrex 100 pump
-
(Westminster, CA), S.B. Weisberg (Ed.)
-
Tran K., Zeng E., F.C., Hallock D. Laboratory and field testing on an Infiltrex 100 pump. Southern California Coastal Water Research Project Annual Report 1994-1995 1997, 137-146. (Westminster, CA). S.B. Weisberg (Ed.).
-
(1997)
Southern California Coastal Water Research Project Annual Report 1994-1995
, pp. 137-146
-
-
Tran, K.1
Zeng, E.F.C.2
Hallock, D.3
-
36
-
-
84960191789
-
Strengthening federal environmental, energy, and transportation management
-
(Washington, DC)
-
U.S.Government Strengthening federal environmental, energy, and transportation management. Executive Order 13423 of January 24, 2007 2007, (Washington, DC).
-
(2007)
Executive Order 13423 of January 24, 2007
-
-
-
37
-
-
84960191790
-
Federal leadership in environmental, energy, and economic performance
-
(Washington, DC)
-
U.S.Government Federal leadership in environmental, energy, and economic performance. Executive Order 13514 of October 5, 2009 2009, (Washington, DC).
-
(2009)
Executive Order 13514 of October 5, 2009
-
-
-
38
-
-
84960191791
-
Planning for federal sustainability in the next decade
-
(Washington, DC)
-
U.S.Government Planning for federal sustainability in the next decade. Executive Order 13693 of March 19, 2015 2015, (Washington, DC).
-
(2015)
Executive Order 13693 of March 19, 2015
-
-
-
42
-
-
84977918247
-
Lab and field screening of 5 selected passive samplers for the measurement of VOC fluxes in groundwater
-
Verreydt G., Bronders J., Van Keer I. Lab and field screening of 5 selected passive samplers for the measurement of VOC fluxes in groundwater. J. Agric. Sci. Appl. 2014, 3(2).
-
(2014)
J. Agric. Sci. Appl.
, vol.3
, Issue.2
-
-
Verreydt, G.1
Bronders, J.2
Van Keer, I.3
-
43
-
-
84883825206
-
Assessment of trace metals during episodic events using DGT passive sampler: a proposal for water management enhancement
-
Villanueva J.D., Le Coustumer P., Huneau F., Montelica-Heino M., Perez T.R., Materum R., Espaldon M.V.O., Stoll S. Assessment of trace metals during episodic events using DGT passive sampler: a proposal for water management enhancement. Water Resour. Manag. 2013, 27(12):4163-4181.
-
(2013)
Water Resour. Manag.
, vol.27
, Issue.12
, pp. 4163-4181
-
-
Villanueva, J.D.1
Le Coustumer, P.2
Huneau, F.3
Montelica-Heino, M.4
Perez, T.R.5
Materum, R.6
Espaldon, M.V.O.7
Stoll, S.8
-
44
-
-
0035499695
-
Membrane-enclosed sorptive coating. An integrative passive sampler for monitoring organic contaminants in water
-
Vrana B., Popp P., Paschke A., Schüürmann G. Membrane-enclosed sorptive coating. An integrative passive sampler for monitoring organic contaminants in water. Anal. Chem. 2001, 73(21):5191-5200.
-
(2001)
Anal. Chem.
, vol.73
, Issue.21
, pp. 5191-5200
-
-
Vrana, B.1
Popp, P.2
Paschke, A.3
Schüürmann, G.4
-
45
-
-
27944443729
-
Passive sampling techniques for monitoring pollutants in water
-
Vrana B., Allan I.J., Greenwood R., Mills G.A., Dominiak E., Svensson K., Knutsson J., Morrison G. Passive sampling techniques for monitoring pollutants in water. TrAC Trends Anal. Chem. 2005, 24(10):845-868.
-
(2005)
TrAC Trends Anal. Chem.
, vol.24
, Issue.10
, pp. 845-868
-
-
Vrana, B.1
Allan, I.J.2
Greenwood, R.3
Mills, G.A.4
Dominiak, E.5
Svensson, K.6
Knutsson, J.7
Morrison, G.8
-
46
-
-
33646406804
-
Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water
-
Vrana B., Mills G.A., Dominiak E., Greenwood R. Calibration of the Chemcatcher passive sampler for the monitoring of priority organic pollutants in water. Environ. Pollut. 2006, 142(2):333-343.
-
(2006)
Environ. Pollut.
, vol.142
, Issue.2
, pp. 333-343
-
-
Vrana, B.1
Mills, G.A.2
Dominiak, E.3
Greenwood, R.4
-
47
-
-
0033105078
-
Field method for the determination of hexavalent chromium by ultrasonication and strong anion-exchange solid-phase extraction
-
Wang J., Ashley K., Marlow D., England E.C., Carlton G. Field method for the determination of hexavalent chromium by ultrasonication and strong anion-exchange solid-phase extraction. Anal. Chem. 1999, 71(5):1027-1032.
-
(1999)
Anal. Chem.
, vol.71
, Issue.5
, pp. 1027-1032
-
-
Wang, J.1
Ashley, K.2
Marlow, D.3
England, E.C.4
Carlton, G.5
-
48
-
-
0022557998
-
Accumulative sampling of trace pesticides and other organics in surface water using xad-4 resin
-
Woodrow J., Majewski M., Seiber J. Accumulative sampling of trace pesticides and other organics in surface water using xad-4 resin. J. Environ. Sci. Health B 1986, 21(2):143-164.
-
(1986)
J. Environ. Sci. Health B
, vol.21
, Issue.2
, pp. 143-164
-
-
Woodrow, J.1
Majewski, M.2
Seiber, J.3
-
49
-
-
84859339217
-
Sampling and sampling strategies for environmental analysis
-
Zhang J., Zhang C. Sampling and sampling strategies for environmental analysis. Int. J. Environ. An. Ch. 2012, 92(4):466-478.
-
(2012)
Int. J. Environ. An. Ch.
, vol.92
, Issue.4
, pp. 466-478
-
-
Zhang, J.1
Zhang, C.2
|