Sensation Feedback and Muscle Response of Electrical Stimulation on the Upper Limb Skin: A Case Study

Author keywords

Electrotactile stimulation; M wave; Muscle response; Sensation feedback

Indexed keywords

MUSCLE; PROSTHETICS; SENSORY FEEDBACK;

EID: 84960086294     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ICMTMA.2015.236     Document Type: Conference Paper
Times cited : (12)

References (13)
  • 1
    • 84870579558 scopus 로고    scopus 로고
    • Vibrotactile sensory substitution elicits feeling of ownership of an alien hand
    • M. D'Alonzo and C. Cipriani, "Vibrotactile sensory substitution elicits feeling of ownership of an alien hand," PLoS One, vol. 7, p. e50756, 2012.
    • (2012) PLoS One , vol.7 , pp. e50756
    • D'Alonzo, M.1    Cipriani, C.2
  • 2
    • 84880894117 scopus 로고    scopus 로고
    • Vibrotactile sensory substitution for electromyographic control of object manipulation
    • Aug
    • E. Rombokas, C.E. Stepp, C. Chang, M. Malhotra, Y. Matsuoka, "Vibrotactile sensory substitution for electromyographic control of object manipulation," IEEE Trans Biomed Eng, vol. 60, pp. 2226-32, Aug 2013.
    • (2013) IEEE Trans Biomed Eng , vol.60 , pp. 2226-2232
    • Rombokas, E.1    Stepp, C.E.2    Chang, C.3    Malhotra, M.4    Matsuoka, Y.5
  • 3
    • 25144513060 scopus 로고    scopus 로고
    • Medical and welfare applications of shape memory alloy microcoil actuators
    • Y. Haga, M. Mizushima, T. Matsunaga, M. Esashi ., "Medical and welfare applications of shape memory alloy microcoil actuators " Smart Mater. Struct., vol. 14, pp. S266-S272, 2005.
    • (2005) Smart Mater. Struct. , vol.14 , pp. S266-S272
    • Haga, Y.1    Mizushima, M.2    Matsunaga, T.3    Esashi, M.4
  • 6
    • 79952145177 scopus 로고    scopus 로고
    • Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees
    • Mar
    • P. D. Marasco, K Kim, JE Colgate, MA Peshkin, TAKuiken "Robotic touch shifts perception of embodiment to a prosthesis in targeted reinnervation amputees," Brain, vol. 134, pp. 747-58, Mar 2011.
    • (2011) Brain , vol.134 , pp. 747-758
    • Marasco, P.D.1    Kim, K.2    Colgate, J.E.3    Peshkin, M.4    Kuiken, T.A.5
  • 7
    • 84871981621 scopus 로고    scopus 로고
    • Artificial redirection of sensation from prosthetic fingers to the phantom hand map on transradial amputees: Vibrotactile versus mechanotactile sensory feedback
    • Jan
    • C. Antfolk, M D'Alonzo, M Controzzi, G Lundborg, B Rosen, F Sebelius, et al., "Artificial redirection of sensation from prosthetic fingers to the phantom hand map on transradial amputees: vibrotactile versus mechanotactile sensory feedback," IEEE Trans Neural Syst Rehabil Eng, vol. 21, pp. 112-20, Jan 2013.
    • (2013) IEEE Trans Neural Syst Rehabil Eng , vol.21 , pp. 112-120
    • Antfolk, C.1    D'Alonzo, M.2    Controzzi, M.3    Lundborg, G.4    Rosen, B.5    Sebelius, F.6
  • 8
    • 84865973189 scopus 로고    scopus 로고
    • Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin
    • Jul
    • C. Antfolk, A. Bjorkman, S.O. Frank, F. Sebelius, G. Lundborg, B. Rosen, "Sensory feedback from a prosthetic hand based on air-mediated pressure from the hand to the forearm skin," J Rehabil Med, vol. 44, pp. 702-7, Jul 2012.
    • (2012) J Rehabil Med , vol.44 , pp. 702-707
    • Antfolk, C.1    Bjorkman, A.2    Frank, S.O.3    Sebelius, F.4    Lundborg, G.5    Rosen, B.6
  • 9
    • 9644300966 scopus 로고    scopus 로고
    • An investigation of the effect of electrode size and electrode location on comfort during stimulation of the gastrocnemius muscle
    • Dec
    • G. M. Lyons, G.E. Leane, M. Clarke-Moloney, J.V. O'Brien, P.A. Grace, "An investigation of the effect of electrode size and electrode location on comfort during stimulation of the gastrocnemius muscle," Med Eng Phys, vol. 26, pp. 873-8, Dec 2004.
    • (2004) Med Eng Phys , vol.26 , pp. 873-878
    • Lyons, G.M.1    Leane, G.E.2    Clarke-Moloney, M.3    O'Brien, J.V.4    Grace, P.A.5
  • 11
    • 0020286575 scopus 로고
    • Electrocutaneous code pairs for artificial sensory communication systems
    • A. Y. Szeto, "Electrocutaneous code pairs for artificial sensory communication systems," Ann Biomed Eng, vol. 10, pp. 175-92, 1982.
    • (1982) Ann Biomed Eng , vol.10 , pp. 175-192
    • Szeto, A.Y.1
  • 12
    • 0002499760 scopus 로고
    • Electrical stimulation of the nervous system: The principle of safe charge injection with noble metal electrodes
    • S. B. Brummer and M. J. Turner, "Electrical stimulation of the nervous system: The principle of safe charge injection with noble metal electrodes," Bioelectrochemistry and Bioenergetic, vol. 2, p. s2, 1975.
    • (1975) Bioelectrochemistry and Bioenergetic , vol.2 , pp. 52
    • Brummer, S.B.1    Turner, M.J.2
  • 13
    • 0034882688 scopus 로고    scopus 로고
    • Depletion and sizes of motor units in spinal muscular atrophy
    • Sep
    • V. Galea, S. Kirsch, A.McComas, "Depletion and sizes of motor units in spinal muscular atrophy," Muscle Nerve, vol. 24, pp. 1168-72, Sep 2001.
    • (2001) Muscle Nerve , vol.24 , pp. 1168-1172
    • Galea, V.1    Kirsch, S.2    McComas, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.