메뉴 건너뛰기




Volumn 281, Issue 1, 2016, Pages 239-248

Validation of software gating: A practical technology for respiratory motion correction in PET

Author keywords

[No Author keywords available]

Indexed keywords

FLUORINE 18; FLUORODEOXYGLUCOSE F 18; RADIOPHARMACEUTICAL AGENT;

EID: 84959442596     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2016152105     Document Type: Article
Times cited : (60)

References (34)
  • 1
    • 84892763724 scopus 로고    scopus 로고
    • Impact of respiratory motion correction and spatial resolution on lesion detection in PET: A simulation study based on real MR dynamic data
    • Polycarpou I, Tsoumpas C, King AP, Marsden PK. Impact of respiratory motion correction and spatial resolution on lesion detection in PET: a simulation study based on real MR dynamic data. Phys Med Biol 2014;59(3):697-713.
    • (2014) Phys Med Biol , vol.59 , Issue.3 , pp. 697-713
    • Polycarpou, I.1    Tsoumpas, C.2    King, A.P.3    Marsden, P.K.4
  • 3
    • 84930356530 scopus 로고    scopus 로고
    • Reconstruction-incorporated respiratory motion correction in clinical simultaneous PET/MR imaging for oncology applications
    • Fayad H, Schmidt H, Wuerslin C, Visvikis D. Reconstruction-incorporated respiratory motion correction in clinical simultaneous PET/MR imaging for oncology applications. J Nucl Med 2015;56(6):884-889.
    • J Nucl Med 2015 , vol.56 , Issue.6 , pp. 884-889
    • Fayad, H.1    Schmidt, H.2    Wuerslin, C.3    Visvikis, D.4
  • 4
    • 77956203253 scopus 로고    scopus 로고
    • Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT
    • Wells RG, Ruddy TD, DeKemp RA, DaSilva JN, Beanlands RS. Single-phase CT aligned to gated PET for respiratory motion correction in cardiac PET/CT. J Nucl Med 2010;51(8):1182-1190.
    • (2010) J Nucl Med , vol.51 , Issue.8 , pp. 1182-1190
    • Wells, R.G.1    Ruddy, T.D.2    DeKemp, R.A.3    DaSilva, J.N.4    Beanlands, R.S.5
  • 5
    • 84865661995 scopus 로고    scopus 로고
    • Respiratory gated PET/CT in a European multicentre retrospective study: Added diagnostic value in detection and characterization of lung lesions
    • Guerra L, De Ponti E, Elisei F, et al. Respiratory gated PET/CT in a European multicentre retrospective study: added diagnostic value in detection and characterization of lung lesions. Eur J Nucl Med Mol Imaging 2012;39(9):1381-1390.
    • (2012) Eur J Nucl Med Mol Imaging , vol.39 , Issue.9 , pp. 1381-1390
    • Guerra, L.1    De Ponti, E.2    Elisei, F.3
  • 6
    • 77957709062 scopus 로고    scopus 로고
    • A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods
    • Kesner AL, Kuntner C. A new fast and fully automated software based algorithm for extracting respiratory signal from raw PET data and its comparison to other methods. Med Phys 2010;37(10):5550-5559.
    • (2010) Med Phys , vol.37 , Issue.10 , pp. 5550-5559
    • Kesner, A.L.1    Kuntner, C.2
  • 7
    • 77957164567 scopus 로고    scopus 로고
    • Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography
    • Büther F, Ernst I, Dawood M, et al. Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography. Eur J Nucl Med Mol Imaging 2010;37(12):2315-2327.
    • (2010) Eur J Nucl Med Mol Imaging , vol.37 , Issue.12 , pp. 2315-2327
    • Büther, F.1    Ernst, I.2    Dawood, M.3
  • 8
    • 84989249722 scopus 로고    scopus 로고
    • Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics
    • Presented at Seoul, South Korea
    • Schleyer PJ, Thielemans K, Marsden PK. Extracting a respiratory signal from raw dynamic PET data that contain tracer kinetics. Presented at IEEE MIC 2013, Seoul, South Korea, 2013.
    • (2013) IEEE MIC 2013
    • Schleyer, P.J.1    Thielemans, K.2    Marsden, P.K.3
  • 10
    • 57849122566 scopus 로고    scopus 로고
    • A novel method for respiratory motion gated with geometric sensitivity of the scanner in 3D PET
    • He J, O'Keefe GJ, Gong SJ, et al. A novel method for respiratory motion gated with geometric sensitivity of the scanner in 3D PET. IEEE Trans Nucl Sci 2008;55(5):2557-2565.
    • (2008) IEEE Trans Nucl Sci , vol.55 , Issue.5 , pp. 2557-2565
    • He, J.1    O'Keefe, G.J.2    Gong, S.J.3
  • 11
    • 84878796448 scopus 로고    scopus 로고
    • Gating, enhanced gating, and beyond: Information utilization strategies for motion management, applied to preclinical PET
    • Kesner AL, Abourbeh G, Mishani E, Chisin R, Tshori S, Freedman N. Gating, enhanced gating, and beyond: information utilization strategies for motion management, applied to preclinical PET. EJNMMI Res 2013;3(1):29.
    • (2013) EJNMMI Res , vol.3 , Issue.1 , pp. 29
    • Kesner, A.L.1    Abourbeh, G.2    Mishani, E.3    Chisin, R.4    Tshori, S.5    Freedman, N.6
  • 12
    • 79960342422 scopus 로고    scopus 로고
    • Extension of a data-driven gating technique to 3D, whole body PET studies
    • Schleyer PJ, O'Doherty MJ, Marsden PK. Extension of a data-driven gating technique to 3D, whole body PET studies. Phys Med Biol 2011;56(13):3953-3965.
    • (2011) Phys Med Biol , vol.56 , Issue.13 , pp. 3953-3965
    • Schleyer, P.J.1    O'Doherty, M.J.2    Marsden, P.K.3
  • 13
    • 84930336343 scopus 로고    scopus 로고
    • Practical PET respiratory motion correction in clinical PET/MR
    • Manber R, Thielemans K, Hutton BF, et al. Practical PET respiratory motion correction in clinical PET/MR. J Nucl Med 2015;56(6):890-896.
    • J Nucl Med 2015 , vol.56 , Issue.6 , pp. 890-896
    • Manber, R.1    Thielemans, K.2    Hutton, B.F.3
  • 14
    • 33748759553 scopus 로고    scopus 로고
    • Multivariate extensions of McNemar's test
    • Klingenberg B, Agresti A. Multivariate extensions of McNemar's test. Biometrics. 2006;62(3):921-928.
    • (2006) Biometrics , vol.62 , Issue.3 , pp. 921-928
    • Klingenberg, B.1    Agresti, A.2
  • 16
    • 0020333131 scopus 로고
    • Random-effects models for longitudinal data
    • Laird NM, Ware JH. Random-effects models for longitudinal data. Biometrics 1982;38(4): 963-974.
    • (1982) Biometrics , vol.38 , Issue.4 , pp. 963-974
    • Laird, N.M.1    Ware, J.H.2
  • 17
    • 0030880605 scopus 로고    scopus 로고
    • Small sample inference for fixed effects from restricted maximum likelihood
    • Kenward MG, Roger JH. Small sample inference for fixed effects from restricted maximum likelihood. Biometrics 1997;53(3):983-997.
    • (1997) Biometrics , vol.53 , Issue.3 , pp. 983-997
    • Kenward, M.G.1    Roger, J.H.2
  • 18
    • 84959442597 scopus 로고    scopus 로고
    • A simulation of noise effects on SUV measurements in gated/ungated data-a story of apples and oranges
    • Kesner AL. A simulation of noise effects on SUV measurements in gated/ungated data-a story of apples and oranges. European Association on Nuclear Medicine, Vienna, Austria, 2010.
    • (2010) European Association on Nuclear Medicine, Vienna, Austria
    • Kesner, A.L.1
  • 19
    • 1542399631 scopus 로고    scopus 로고
    • Respiratory gating for 3-dimensional PET of the thorax: Feasibility and initial results
    • Boucher L, Rodrigue S, Lecomte R, Bénard F. Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J Nucl Med 2004;45(2):214-219.
    • (2004) J Nucl Med , vol.45 , Issue.2 , pp. 214-219
    • Boucher, L.1    Rodrigue, S.2    Lecomte, R.3    Bénard, F.4
  • 20
    • 0036305067 scopus 로고    scopus 로고
    • Effect of respiratory gating on quantifying PET images of lung cancer
    • Nehmeh SA, Erdi YE, Ling CC, et al. Effect of respiratory gating on quantifying PET images of lung cancer. J Nucl Med 2002; 43(7):876-881.
    • (2002) J Nucl Med , vol.43 , Issue.7 , pp. 876-881
    • Nehmeh, S.A.1    Erdi, Y.E.2    Ling, C.C.3
  • 21
    • 84938849601 scopus 로고    scopus 로고
    • Repeatability of 18F-FDG PET/CT in advanced non-small cell lung cancer: Prospective assessment in 2 multicenter trials
    • Weber WA, Gatsonis CA, Mozley PD, et al. Repeatability of 18F-FDG PET/CT in advanced non-small cell lung cancer: prospective assessment in 2 multicenter trials. J Nucl Med 2015;56(8):1137-1143.
    • J Nucl Med 2015 , vol.56 , Issue.8 , pp. 1137-1143
    • Weber, W.A.1    Gatsonis, C.A.2    Mozley, P.D.3
  • 23
    • 41549141266 scopus 로고    scopus 로고
    • Respiratory motion in positron emission tomography/computed tomography: A review
    • Nehmeh SA, Erdi YE. Respiratory motion in positron emission tomography/computed tomography: a review. Semin Nucl Med 2008;38(3):167-176.
    • (2008) Semin Nucl Med , vol.38 , Issue.3 , pp. 167-176
    • Nehmeh, S.A.1    Erdi, Y.E.2
  • 24
    • 77956185666 scopus 로고    scopus 로고
    • Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques
    • Bettinardi V, Picchio M, Di Muzio N, Gianolli L, Gilardi MC, Messa C. Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques. Radiother Oncol 2010;96(3):311-316.
    • (2010) Radiother Oncol , vol.96 , Issue.3 , pp. 311-316
    • Bettinardi, V.1    Picchio, M.2    Di Muzio, N.3    Gianolli, L.4    Gilardi, M.C.5    Messa, C.6
  • 25
    • 53649111422 scopus 로고    scopus 로고
    • Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny
    • Daou D. Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny. Eur J Nucl Med Mol Imaging 2008;35(11):1961-1970.
    • (2008) Eur J Nucl Med Mol Imaging , vol.35 , Issue.11 , pp. 1961-1970
    • Daou, D.1
  • 26
    • 57549105688 scopus 로고    scopus 로고
    • Strategies for motion tracking and correction in PET
    • Rahmim A, Rousset O, Zaidi H. Strategies for motion tracking and correction in PET. PET Clin 2007;2(2):251-266.
    • (2007) PET Clin , vol.2 , Issue.2 , pp. 251-266
    • Rahmim, A.1    Rousset, O.2    Zaidi, H.3
  • 27
    • 71949083009 scopus 로고    scopus 로고
    • The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging
    • Liu C, Pierce LA 2nd, Alessio AM, Kinahan PE. The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging. Phys Med Biol 2009;54(24):7345-7362.
    • (2009) Phys Med Biol , vol.54 , Issue.24 , pp. 7345-7362
    • Liu, C.1    Alessio, A.M.2    Kinahan, P.E.3
  • 30
    • 84959449299 scopus 로고    scopus 로고
    • Frequency based gating: An alternative, conformal, approach to 4D PET data utilization
    • Kesner AL, Chung JH, Lind KE, et al. Frequency based gating: An alternative, conformal, approach to 4D PET data utilization. Med Phys. 2016;43(3):1451.
    • (2016) Med Phys , vol.43 , Issue.3 , pp. 1451
    • Kesner, A.L.1    Chung, J.H.2    Lind, K.E.3
  • 31
    • 84952988949 scopus 로고    scopus 로고
    • Carpe datum: A consideration of the barriers and potential of data-driven PET innovation
    • Kesner AL, Daou D, Schindler TH, Koo PJ. Carpe datum: a consideration of the barriers and potential of data-driven PET innovation. J Am Coll Radiol 2016;13(1):106-108.
    • (2016) J Am Coll Radiol , vol.13 , Issue.1 , pp. 106-108
    • Kesner, A.L.1    Daou, D.2    Schindler, T.H.3    Koo, P.J.4
  • 32
    • 84952993820 scopus 로고    scopus 로고
    • On transcending the impasse of respiratory motion correction applications in routine clinical imaging-a consideration of a fully automated data driven motion control framework
    • Kesner AL, Schleyer PJ, Büther F, Walter MA, Schäfers KP, Koo PJ. On transcending the impasse of respiratory motion correction applications in routine clinical imaging-a consideration of a fully automated data driven motion control framework. EJNMMI Phys 2014;1(1):8.
    • (2014) EJNMMI Phys , vol.1 , Issue.1 , pp. 8
    • Kesner, A.L.1    Schleyer, P.J.2    Büther, F.3    Walter, M.A.4    Schäfers, K.P.5    Koo, P.J.6
  • 33
    • 84941915006 scopus 로고    scopus 로고
    • A prospective investigation into the clinical impact of 4D-PET/CT in the characterisation of solitary pulmonary nodules
    • Callahan J, Kron T, Schneider ME, Hicks RJ. A prospective investigation into the clinical impact of 4D-PET/CT in the characterisation of solitary pulmonary nodules. Cancer Imaging 2014;14:24.
    • (2014) Cancer Imaging , vol.14 , pp. 24
    • Callahan, J.1    Kron, T.2    Schneider, M.E.3    Hicks, R.J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.