메뉴 건너뛰기




Volumn 173, Issue , 2011, Pages 130-136

Polyethersulfone as a high-performance membrane

Author keywords

[No Author keywords available]

Indexed keywords

BETA 2 MICROGLOBULIN; BIOMATERIAL; ENDOTOXIN; PLASMA PROTEIN; POLYETHERSULFONE; POLYMER; PYROGEN; SERUM ALBUMIN; SULFONE;

EID: 84958674245     PISSN: 03025144     EISSN: None     Source Type: Book Series    
DOI: 10.1159/000329051     Document Type: Article
Times cited : (31)

References (12)
  • 4
    • 0035203506 scopus 로고    scopus 로고
    • Nanoscale modulation of the pore dimensions, size distribution and structure of a new polysulfone based highflux dialysis membrane
    • Ronco C, Bowry S: Nanoscale modulation of the pore dimensions, size distribution and structure of a new polysulfone based highflux dialysis membrane. Int J Artif Organs 2001, 24:726-735.
    • (2001) Int J Artif Organs , vol.24 , pp. 726-735
    • Ronco, C.1    Bowry, S.2
  • 6
    • 58149198052 scopus 로고    scopus 로고
    • Matching efficacy of online hemodiafiltration in simple hemodialysis mode
    • Krieter DH, Hunn E, Morgenroth A, Lemke HD, Wanner C: Matching efficacy of online hemodiafiltration in simple hemodialysis mode. Artif Organs 2008;32:903-909.
    • (2008) Artif Organs , vol.32 , pp. 903-909
    • Krieter, D.H.1    Hunn, E.2    Morgenroth, A.3    Lemke, H.D.4    Wanner, C.5
  • 7
    • 3042524994 scopus 로고    scopus 로고
    • Clinical evaluation of internal hemodiafiltration: Diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers
    • Lucchi L, Fiore GB, Guadagni G, Perrone S, Malaguti V, Caruso F, Fumero R, Albertazzi A: Clinical evaluation of internal hemodiafiltration: diffusive-convective technique performed with internal filtration enhanced high-flux dialyzers. Int J Artif Organs 2004, 27:414-419.
    • (2004) Int J Artif Organs , vol.27 , pp. 414-419
    • Lucchi, L.1    Fiore, G.B.2    Guadagni, G.3    Perrone, S.4    Malaguti, V.5    Caruso, F.6    Fumero, R.7    Albertazzi, A.8
  • 8
    • 11244329627 scopus 로고    scopus 로고
    • Development of a dialyzer with enhanced internal filtration to increase the clearance of low-molecularweight proteins
    • Fujimura T, Uchi Y, Fukuda M, Miyazaki M, Uezumi S, Hiyoshi T: Development of a dialyzer with enhanced internal filtration to increase the clearance of low-molecularweight proteins. J Artif Organs 2004, 7:149-154.
    • (2004) J Artif Organs , vol.7 , pp. 149-154
    • Fujimura, T.1    Uchi, Y.2    Fukuda, M.3    Miyazaki, M.4    Uezumi, S.5    Hiyoshi, T.6
  • 9
    • 0037385323 scopus 로고    scopus 로고
    • High permeability of dialysis membranes: What is the limit of albumin loss?
    • Krieter DH, Canaud B: High permeability of dialysis membranes: what is the limit of albumin loss? Nephrol Dial Transplant 2003;18:651-654.
    • (2003) Nephrol Dial Transplant , vol.18 , pp. 651-654
    • Krieter, D.H.1    Canaud, B.2
  • 11
    • 80052068208 scopus 로고    scopus 로고
    • Permeability and pyrogen retention of dialysis membranes are inversely related
    • Lemke HD, Wanner C, Krieter DH: Permeability and pyrogen retention of dialysis membranes are inversely related. Kidney Dial 2010;69(suppl):59-64.
    • (2010) Kidney Dial , vol.69 , Issue.SUPPL. , pp. 59-64
    • Lemke, H.D.1    Wanner, C.2    Krieter, D.H.3
  • 12
    • 47349110312 scopus 로고    scopus 로고
    • A new synthetic dialyzer with advanced permselectivity for enhanced low-molecular-weight protein removal
    • Krieter DH, Lemke HD, Wanner C: A new synthetic dialyzer with advanced permselectivity for enhanced low-molecular-weight protein removal. Artif Organs 2008, 32:547-554.
    • (2008) Artif Organs , vol.32 , pp. 547-554
    • Krieter, D.H.1    Lemke, H.D.2    Wanner, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.