-
1
-
-
74249100596
-
The efficacy of plate construct augmentation versus cage alone in anterior cervical fusion
-
Song KJ, Taghavi CE, Lee KB, The efficacy of plate construct augmentation versus cage alone in anterior cervical fusion. Spine 2009; 34: 2886-92.
-
(2009)
Spine
, vol.34
, pp. 2886-2892
-
-
Song, K.J.1
Taghavi, C.E.2
Lee, K.B.3
-
2
-
-
85047695725
-
Anterior approaches to fusion of the cervical spine: A metaanalysis of fusion rates
-
Fraser JF, Hartl R,. Anterior approaches to fusion of the cervical spine: a metaanalysis of fusion rates. J Neurosurg Spine 2007; 6: 298-303.
-
(2007)
J Neurosurg Spine
, vol.6
, pp. 298-303
-
-
Fraser, J.F.1
Hartl, R.2
-
3
-
-
27944480024
-
Dysphagia after anterior cervical decompression and fusion: Prevalence and risk factors from a longitudinal cohort study
-
Riley LH, Skolasky RL, Albert TJ, Dysphagia after anterior cervical decompression and fusion: prevalence and risk factors from a longitudinal cohort study. Spine 2005; 30: 2564-9.
-
(2005)
Spine
, vol.30
, pp. 2564-2569
-
-
Riley, L.H.1
Skolasky, R.L.2
Albert, T.J.3
-
5
-
-
35848950708
-
Role of plate thickness as a cause of dysphagia after anterior cervical
-
Chin KR, Eiszner JR, Adams SB Jr,. Role of plate thickness as a cause of dysphagia after anterior cervical. Spine 2007; 32: 2585-90.
-
(2007)
Spine
, vol.32
, pp. 2585-2590
-
-
Chin, K.R.1
Eiszner, J.R.2
Adams, S.B.3
-
6
-
-
76649117728
-
Lower incidence of dysphagia with cervical arthroplasty compared with ACDF in a prospective randomized clinical trial
-
McAfee PC, Cappuccino A, Cunningham BW, Lower incidence of dysphagia with cervical arthroplasty compared with ACDF in a prospective randomized clinical trial. J Spinal Disord Tech 2010; 23: 1-8.
-
(2010)
J Spinal Disord Tech
, vol.23
, pp. 1-8
-
-
McAfee, P.C.1
Cappuccino, A.2
Cunningham, B.W.3
-
7
-
-
64049115744
-
A new stand-alone cervical anterior interbody fusion device: Biomechanical comparison with established anterior cervical fixation devices
-
Scholz M, Reyes PM, Schleicher P, A new stand-alone cervical anterior interbody fusion device: biomechanical comparison with established anterior cervical fixation devices. Spine 2009; 34: 156-60.
-
(2009)
Spine
, vol.34
, pp. 156-160
-
-
Scholz, M.1
Reyes, P.M.2
Schleicher, P.3
-
8
-
-
84872388834
-
Biomechanical evaluation of a low profile, anchored cervical interbody spacer device in the setting of progressive flexion-distraction injury of the cervical spine
-
Wojewnik B, Ghanayem AJ, Tsitsopoulos PP, Biomechanical evaluation of a low profile, anchored cervical interbody spacer device in the setting of progressive flexion-distraction injury of the cervical spine. Eur Spine J 2012; 22: 135-41.
-
(2012)
Eur Spine J
, vol.22
, pp. 135-141
-
-
Wojewnik, B.1
Ghanayem, A.J.2
Tsitsopoulos, P.P.3
-
9
-
-
84862205615
-
A comparative biomechanical study of a novel integrated plate spacer for stabilization of cervical spine: An in vitro human cadaveric model
-
Majid K, Chinthakunta S, Muzumdar A, A comparative biomechanical study of a novel integrated plate spacer for stabilization of cervical spine: an in vitro human cadaveric model. Clin Biomech 2012; 27: 532-6.
-
(2012)
Clin Biomech
, vol.27
, pp. 532-536
-
-
Majid, K.1
Chinthakunta, S.2
Muzumdar, A.3
-
10
-
-
79953051432
-
A new zero-profile implant for stand-alone anterior cervical interbody fusion
-
Scholz M, Schnake KJ, Pingel A, A new zero-profile implant for stand-alone anterior cervical interbody fusion. Clin Orthop Relat Res 2010; 469: 666-73.
-
(2010)
Clin Orthop Relat Res
, vol.469
, pp. 666-673
-
-
Scholz, M.1
Schnake, K.J.2
Pingel, A.3
-
11
-
-
84892730114
-
Zero-P: A new zero-profile cage-plate device for single and multilevel ACDF. A single Institution series with four years maximum follow-up and review of the literature on zero-profile devices
-
Barbagallo GMV, Romano D, Certo F, Zero-P: a new zero-profile cage-plate device for single and multilevel ACDF. A single Institution series with four years maximum follow-up and review of the literature on zero-profile devices. Eur Spine J 2013; 22: 868-78.
-
(2013)
Eur Spine J
, vol.22
, pp. 868-878
-
-
Barbagallo, G.M.V.1
Romano, D.2
Certo, F.3
-
12
-
-
84948580318
-
The efficiency of zero-profile implant in anterior cervical discectomy fusion: A prospective controlled long-term follow-up study [Published online ahead of print October 16, 2013]
-
Li Y, Hao D, He B, The efficiency of zero-profile implant in anterior cervical discectomy fusion: a prospective controlled long-term follow-up study [Published online ahead of print October 16, 2013]. J Spinal Disord Tech.
-
J Spinal Disord Tech
-
-
Li, Y.1
Hao, D.2
He, B.3
-
13
-
-
84858222772
-
The biomechanical stability of a novel spacer with integrated plate in contiguous two-level and three-level ACDF models: An in vitro cadaveric study
-
Clavenna AL, Beutler WJ, Gudipally M, The biomechanical stability of a novel spacer with integrated plate in contiguous two-level and three-level ACDF models: an in vitro cadaveric study. Spine J 2012; 12: 157-63.
-
(2012)
Spine J
, vol.12
, pp. 157-163
-
-
Clavenna, A.L.1
Beutler, W.J.2
Gudipally, M.3
-
14
-
-
84905443693
-
Do stand-alone interbody spacers with integrated screws provide adequate segmental stability for multilevel cervical arthrodesis?
-
Paik H, Kang DG, Lehman RA Jr, Do stand-alone interbody spacers with integrated screws provide adequate segmental stability for multilevel cervical arthrodesis? Spine J 2014; 14: 1740-7.
-
(2014)
Spine J
, vol.14
, pp. 1740-1747
-
-
Paik, H.1
Kang, D.G.2
Lehman, R.A.3
-
15
-
-
0029096617
-
An apparatus for applying pure nonconstraining moments to spine segments in vitro
-
Crawford NR, Brantley AG, Dickman CA, An apparatus for applying pure nonconstraining moments to spine segments in vitro. Spine 1995; 20: 2097-100.
-
(1995)
Spine
, vol.20
, pp. 2097-2100
-
-
Crawford, N.R.1
Brantley, A.G.2
Dickman, C.A.3
-
16
-
-
0031924426
-
Testing criteria for spinal implants: Recommendations for the standardization of in vitro stability testing of spinal implants
-
Wilke HJ, Wenger K, Claes L,. Testing criteria for spinal implants: recommendations for the standardization of in vitro stability testing of spinal implants. Eur Spine J 1998; 7: 148-54.
-
(1998)
Eur Spine J
, vol.7
, pp. 148-154
-
-
Wilke, H.J.1
Wenger, K.2
Claes, L.3
-
17
-
-
49449118813
-
Systematic accuracy and precision analysis of video motion capturing systems-exemplified on the Vicon-460 system
-
Windolf M, Götzen N, Morlock M,. Systematic accuracy and precision analysis of video motion capturing systems-exemplified on the Vicon-460 system. J Biomech 2008; 41: 2776-80.
-
(2008)
J Biomech
, vol.41
, pp. 2776-2780
-
-
Windolf, M.1
Götzen, N.2
Morlock, M.3
-
18
-
-
0028046043
-
Biomechanical analysis of facet and graft loading in a Smith-Robinson type cervical spine model
-
Olsewski JM, Garvey TA, Schendel MJ,. Biomechanical analysis of facet and graft loading in a Smith-Robinson type cervical spine model. Spine 1994; 19: 2540-4.
-
(1994)
Spine
, vol.19
, pp. 2540-2544
-
-
Olsewski, J.M.1
Garvey, T.A.2
Schendel, M.J.3
-
19
-
-
42149092625
-
Delayed migration of a screw into the gastrointestinal tract after anterior cervical spine plating
-
Gazzeri R, Tamorri M, Faiola A, Delayed migration of a screw into the gastrointestinal tract after anterior cervical spine plating. Spine 2008; 33: E268-71.
-
(2008)
Spine
, vol.33
, pp. E268-E271
-
-
Gazzeri, R.1
Tamorri, M.2
Faiola, A.3
-
20
-
-
34848889601
-
Anterior cervical discectomy and fusion associated complications
-
Fountas KN, Kapsalaki EZ, Nikolakakos LG, Anterior cervical discectomy and fusion associated complications. Spine 2007; 32: 2310-7.
-
(2007)
Spine
, vol.32
, pp. 2310-2317
-
-
Fountas, K.N.1
Kapsalaki, E.Z.2
Nikolakakos, L.G.3
-
21
-
-
33646714118
-
Delayed hypopharyngeal and esophageal perforation after anterior spinal fusion
-
Pichler W, Maier A, Rappl T, Delayed hypopharyngeal and esophageal perforation after anterior spinal fusion. Spine 2006; 31: E268-70.
-
(2006)
Spine
, vol.31
, pp. E268-E270
-
-
Pichler, W.1
Maier, A.2
Rappl, T.3
-
22
-
-
84888133129
-
Comparison of dysphagia between cervical artificial disc replacement and fusion
-
Skeppholm M, Olerud C,. Comparison of dysphagia between cervical artificial disc replacement and fusion. Spine 2013; 38: E1507-10.
-
(2013)
Spine
, vol.38
, pp. E1507-E1510
-
-
Skeppholm, M.1
Olerud, C.2
-
23
-
-
84890550757
-
Biomechanics of an integrated interbody device versus ACDF anterior locking plate in a single-level cervical spine fusion construct
-
Stein MI, Nayak AN, Gaskins RB III, Biomechanics of an integrated interbody device versus ACDF anterior locking plate in a single-level cervical spine fusion construct. Spine J 2014; 14: 128-36.
-
(2014)
Spine J
, vol.14
, pp. 128-136
-
-
Stein, M.I.1
Nayak, A.N.2
Gaskins, R.B.3
|