메뉴 건너뛰기




Volumn 54, Issue , 2016, Pages 212-217

The effects of a passive exoskeleton on muscle activity, discomfort and endurance time in forward bending work

Author keywords

Discomfort; Electromyography; Endurance; Exoskeleton; Industry; Trunk bending

Indexed keywords

DURABILITY; ELECTROMYOGRAPHY; INDUSTRY; MUSCLE;

EID: 84958053885     PISSN: 00036870     EISSN: 18729126     Source Type: Journal    
DOI: 10.1016/j.apergo.2015.12.003     Document Type: Article
Times cited : (310)

References (23)
  • 1
    • 33646476422 scopus 로고    scopus 로고
    • An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasks
    • Abdoli-Eramaki M., Agnew M., Stevenson J. An on-body personal lift augmentation device (PLAD) reduces EMG amplitude of erector spinae during lifting tasks. Clin. Biomech. 2008, 21:456-465.
    • (2008) Clin. Biomech. , vol.21 , pp. 456-465
    • Abdoli-Eramaki, M.1    Agnew, M.2    Stevenson, J.3
  • 3
    • 79551622173 scopus 로고    scopus 로고
    • The effect of work pace on workload, motor variability and fatigue during simulated light assembly work
    • Bosch T., Mathiassen S.E., Visser B., Looze de M.P., Dieën van J.H. The effect of work pace on workload, motor variability and fatigue during simulated light assembly work. Ergonomics 2011, 54(2):154-168.
    • (2011) Ergonomics , vol.54 , Issue.2 , pp. 154-168
    • Bosch, T.1    Mathiassen, S.E.2    Visser, B.3    Looze, D.M.P.4    Dieën, V.J.H.5
  • 4
    • 77749309531 scopus 로고    scopus 로고
    • Risk factors for work-related musculoskeletal disorders: a systematic review of recent longitudinal studies
    • Da Costa B.R., Vieira E.R. Risk factors for work-related musculoskeletal disorders: a systematic review of recent longitudinal studies. Am. J. Ind. Med. 2010, 53(3):285-323.
    • (2010) Am. J. Ind. Med. , vol.53 , Issue.3 , pp. 285-323
    • Da Costa, B.R.1    Vieira, E.R.2
  • 5
  • 7
    • 67349092792 scopus 로고    scopus 로고
    • Effectiveness of an on-body lifting aid at reducing low back physical demands during an automotive assembly task: assessment of EMG response and user acceptability
    • Graham R.B., Agnew M.J., Stevenson J.M. Effectiveness of an on-body lifting aid at reducing low back physical demands during an automotive assembly task: assessment of EMG response and user acceptability. Appl. Ergon. 2009, 40(5):936-942.
    • (2009) Appl. Ergon. , vol.40 , Issue.5 , pp. 936-942
    • Graham, R.B.1    Agnew, M.J.2    Stevenson, J.M.3
  • 9
    • 0002812616 scopus 로고
    • Test-retest reliability of a practical method for measuring body part discomfort
    • Taylor & Francis, London, Y. Quéinnec, F. Daniellou (Eds.)
    • Grinten van der M.P. Test-retest reliability of a practical method for measuring body part discomfort. Designing for Everyone 1991, 54-57. Taylor & Francis, London. Y. Quéinnec, F. Daniellou (Eds.).
    • (1991) Designing for Everyone , pp. 54-57
    • Grinten van der, M.P.1
  • 10
    • 0037233822 scopus 로고    scopus 로고
    • The health and productivity cost burden of the "top 10" physical and mental health conditions affecting six large U.S. employers in 1999
    • Goetzel R.Z., Hawkins K., Ozminkowski R.J., Wang S. The health and productivity cost burden of the "top 10" physical and mental health conditions affecting six large U.S. employers in 1999. J. Occup. Environ. Med. 2003, 45(1):5-14.
    • (2003) J. Occup. Environ. Med. , vol.45 , Issue.1 , pp. 5-14
    • Goetzel, R.Z.1    Hawkins, K.2    Ozminkowski, R.J.3    Wang, S.4
  • 13
    • 0033813270 scopus 로고    scopus 로고
    • Development of recommendations for sEMG sensors and sensor placement procedures
    • Hermens H.J., Freriks B., Disselhorst-Klug C., Rau G. Development of recommendations for sEMG sensors and sensor placement procedures. J. Electromyogr. Kinesiol. 2000, 10(5):361-374.
    • (2000) J. Electromyogr. Kinesiol. , vol.10 , Issue.5 , pp. 361-374
    • Hermens, H.J.1    Freriks, B.2    Disselhorst-Klug, C.3    Rau, G.4
  • 15
    • 84921439131 scopus 로고    scopus 로고
    • Effect of horizontal pick and place locations on shoulder kinematics
    • Könemann R., Bosch T., Kingma I., Van Dieën J.H., De Looze M.P. Effect of horizontal pick and place locations on shoulder kinematics. Ergonomics 2015, 58(2):195-207.
    • (2015) Ergonomics , vol.58 , Issue.2 , pp. 195-207
    • Könemann, R.1    Bosch, T.2    Kingma, I.3    Van Dieën, J.H.4    De Looze, M.P.5
  • 16
    • 84868117456 scopus 로고    scopus 로고
    • Biomechanical evaluation of the Eco-Pick lift assist: a device designed to facilitate product selection tasks in distribution centers
    • Lavender S.A., Ko P., Sommerich C.M. Biomechanical evaluation of the Eco-Pick lift assist: a device designed to facilitate product selection tasks in distribution centers. Appl. Ergon. 2013, 44(2):230-236.
    • (2013) Appl. Ergon. , vol.44 , Issue.2 , pp. 230-236
    • Lavender, S.A.1    Ko, P.2    Sommerich, C.M.3
  • 17
    • 84863944551 scopus 로고    scopus 로고
    • The technical trend of the exoskeleton robot system for human power assistance
    • Lee H., Kim W., Han J., Han C. The technical trend of the exoskeleton robot system for human power assistance. Int. J. Precis. Eng. Manuf. 2012, 13(8):1491-1497.
    • (2012) Int. J. Precis. Eng. Manuf. , vol.13 , Issue.8 , pp. 1491-1497
    • Lee, H.1    Kim, W.2    Han, J.3    Han, C.4
  • 18
    • 84945218492 scopus 로고    scopus 로고
    • Exoskeletons for industrial application and their potential effects on physical work load
    • Looze de M.P., Bosch T., Krause F., Stadler K.S., O'Sullivan L.W. Exoskeletons for industrial application and their potential effects on physical work load. Ergonomics 2015, http://dx.doi.org/10.1080/00140139.2015.1081988.
    • (2015) Ergonomics
    • Looze de, M.P.1    Bosch, T.2    Krause, F.3    Stadler, K.S.4    O'Sullivan, L.W.5
  • 19
    • 59149098841 scopus 로고    scopus 로고
    • The effect of an on-body personal lift assist device (PLAD) on fatigue during a repetitive lifting task
    • Lotz C.A., Agnew M.J., Godwin A.A., Stevenson J.M. The effect of an on-body personal lift assist device (PLAD) on fatigue during a repetitive lifting task. J. Electromyogr. Kinesiol 2009, 19(2):e331-340.
    • (2009) J. Electromyogr. Kinesiol , vol.19 , Issue.2 , pp. e331-340
    • Lotz, C.A.1    Agnew, M.J.2    Godwin, A.A.3    Stevenson, J.M.4
  • 20
    • 84887912288 scopus 로고    scopus 로고
    • Wearable stooping-assist device in reducing risk of low back disorders during stooped work
    • Luo Z., Yu Y. Wearable stooping-assist device in reducing risk of low back disorders during stooped work. IEEE Int. Conf. Mechatronics Autom. 2013, 2013:230-236.
    • (2013) IEEE Int. Conf. Mechatronics Autom. , vol.2013 , pp. 230-236
    • Luo, Z.1    Yu, Y.2
  • 21
    • 84873121435 scopus 로고    scopus 로고
    • Subject-specific, whole-body models of the stooped posture with a personal weight transfer device
    • Ulrey B.L., Fathallah F.A. Subject-specific, whole-body models of the stooped posture with a personal weight transfer device. J. Electromyogr. Kinesiol. 2013, 23(1):206-215.
    • (2013) J. Electromyogr. Kinesiol. , vol.23 , Issue.1 , pp. 206-215
    • Ulrey, B.L.1    Fathallah, F.A.2
  • 22
    • 84873111472 scopus 로고    scopus 로고
    • Effect of a personal weight transfer device on muscle activities and joint flexions in the stooped posture
    • Ulrey B.L., Fathallah F.A. Effect of a personal weight transfer device on muscle activities and joint flexions in the stooped posture. J. Electromyogr. Kinesiol. 2013, 23(1):195-205.
    • (2013) J. Electromyogr. Kinesiol. , vol.23 , Issue.1 , pp. 195-205
    • Ulrey, B.L.1    Fathallah, F.A.2
  • 23
    • 84887794276 scopus 로고    scopus 로고
    • Effect of an on-body ergonomic aid on oxygen consumption during a repetitive lifting task
    • Whitfield B.H., Costigan P.A., Stevenson J.M., Smallman C.L. Effect of an on-body ergonomic aid on oxygen consumption during a repetitive lifting task. Int. J. Ind. Ergon. 2014, 44(1):39-44.
    • (2014) Int. J. Ind. Ergon. , vol.44 , Issue.1 , pp. 39-44
    • Whitfield, B.H.1    Costigan, P.A.2    Stevenson, J.M.3    Smallman, C.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.