-
1
-
-
75449123150
-
A simple phenylanaline method for detecting phenylketonuria in large populations of newborn infants
-
Guthrie R, Suzi A. A simple phenylanaline method for detecting phenylketonuria in large populations of newborn infants. Pediatrics 32, 338-343 (1963).
-
(1963)
Pediatrics
, vol.32
, pp. 338-343
-
-
Guthrie, R.1
Suzi, A.2
-
2
-
-
0021055497
-
Analysis for filter-paper absorbed, finger-stick blood samples for chloroquine and its major metabolites using HPLC with fluorescence detection
-
Patchen LC, Mount DL, Schwartz IK, Churchill FC. Analysis for filter-paper absorbed, finger-stick blood samples for chloroquine and its major metabolites using HPLC with fluorescence detection. J. Chromatogr. 278, 81-89 (1983).
-
(1983)
J. Chromatogr.
, vol.278
, pp. 81-89
-
-
Patchen, L.C.1
Mount, D.L.2
Schwartz, I.K.3
Churchill, F.C.4
-
3
-
-
0006935651
-
Neonatal screening using dried blood spotted on filter paper: Methodological factors which contribute to imprecision
-
Therell BL Jr (Ed.). Elsevier Publishing Co., NY, USA
-
Arends J. Neonatal screening using dried blood spotted on filter paper: methodological factors which contribute to imprecision. In: Neonatal Screening (Proceedings of the 6th Neonatal Screening Symposium). Therell BL Jr (Ed.). Elsevier Publishing Co., NY, USA, 549-550 (1987).
-
(1987)
Neonatal Screening (Proceedings of the 6th Neonatal Screening Symposium
, pp. 549-550
-
-
Arends, J.1
-
4
-
-
0027298412
-
Influence of hematocrit on quantitative analysis of blood spots'on filter paper
-
O'Broin S. Influence of hematocrit on quantitative analysis of blood spots'on filter paper. Clin. Chem. 39(6), 1354-1355 (1993).
-
(1993)
Clin. Chem.
, vol.39
, Issue.6
, pp. 1354-1355
-
-
O'Broin, S.1
-
5
-
-
84871761741
-
Prediction of the hematocrit of dried blood spots via potassium measurement on a routine clinical chemistry
-
Capiau S, Stove VV, Lambert WE, Stove CP. Prediction of the hematocrit of dried blood spots via potassium measurement on a routine clinical chemistry. Analyzer Anal. Chem. 85, 404-410 (2013).
-
(2013)
Analyzer Anal. Chem.
, vol.85
, pp. 404-410
-
-
Capiau, S.1
Stove, V.V.2
Lambert, W.E.3
Stove, C.P.4
-
6
-
-
84956985193
-
Diffuse reflectance for relating percent hematocrit to correct for sample volume on dried blood spot
-
Presented at: Chicago, IL, USA, October
-
John H, Miller IV, Poston PA, Rutan SC, Karnes HT. Diffuse reflectance for relating percent hematocrit to correct for sample volume on dried blood spot. Presented at: 2013 American Association of Pharmaceutical Scientists Annual Meeting and Exposition. Chicago, IL, USA, 14-18 October 2012.
-
(2012)
2013 American Association of Pharmaceutical Scientists Annual Meeting and Exposition
, pp. 14-18
-
-
John, H.1
Miller, I.V.2
Poston, P.A.3
Rutan, S.C.4
Karnes, H.T.5
-
7
-
-
79955001689
-
Determination of moxifloxacin in dried blood spots using LC-MS/MS and the impact of the hematocrit and blood volume
-
Vu DH, Koster RA, Alffenaar JWC, Brouwers JRBJ, Uges DRA. Determination of moxifloxacin in dried blood spots using LC-MS/MS and the impact of the hematocrit and blood volume. J. Chromatogr. 879, 1063-1070 (2011).
-
(2011)
J. Chromatogr.
, vol.879
, pp. 1063-1070
-
-
Vu, D.H.1
Koster, R.A.2
Alffenaar, J.W.C.3
Brouwers, J.R.B.J.4
Uges, D.R.A.5
-
8
-
-
33747877255
-
Influence of hematocrit and localisation of punch in dried blood spots on levels of amino acids and acylcarnitines measured by tandem mass spectrometry
-
Holub M, Tuschl K, Ratschmann R et al. Influence of hematocrit and localisation of punch in dried blood spots on levels of amino acids and acylcarnitines measured by tandem mass spectrometry. Clinica Chimica Acta 373, 27-31 (2006).
-
(2006)
Clinica Chimica Acta
, vol.373
, pp. 27-31
-
-
Holub, M.1
Tuschl, K.2
Ratschmann, R.3
-
9
-
-
79953137467
-
The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs
-
Denniff P, Spooner N. The effect of hematocrit on assay bias when using DBS samples for the quantitative bioanalysis of drugs. Bioanalysis 2(8), 1385-1395 (2010).
-
(2010)
Bioanalysis
, vol.2
, Issue.8
, pp. 1385-1395
-
-
Denniff, P.1
Spooner, N.2
-
10
-
-
80052603251
-
Pre-cut dried blood spot (PCDBS): An alternative to dried blood spot (DBS) technique to overcome hematocrit impact
-
Youhnovski N, Bergeron A, Furtado M, Garofolo F. Pre-cut dried blood spot (PCDBS): an alternative to dried blood spot (DBS) technique to overcome hematocrit impact. Rapid Commun. Mass Spectrom. 25, 2951-2958 (2011).
-
(2011)
Rapid Commun. Mass Spectrom.
, vol.25
, pp. 2951-2958
-
-
Youhnovski, N.1
Bergeron, A.2
Furtado, M.3
Garofolo, F.4
|