메뉴 건너뛰기




Volumn 10, Issue 1, 2016, Pages

End-to-end automated microfluidic platform for synthetic biology: From design to functional analysis

Author keywords

Analysis; Cell culture; DNA assembly; Microfluidics; Synthetic biology; Transformation

Indexed keywords

ARTICLE; AUTOMATION; BIOCHIP; CELL GROWTH; COMPUTER PROGRAM; DNA SYNTHESIS; ESCHERICHIA COLI; GENE EXPRESSION; GENETIC ENGINEERING; GENETIC TRANSFORMATION; METABOLISM; MICROFLUIDICS; NONHUMAN; PRIORITY JOURNAL; PROTEOMICS; SACCHAROMYCES CEREVISIAE; SYNTHETIC BIOLOGY;

EID: 84956933515     PISSN: None     EISSN: 17541611     Source Type: Journal    
DOI: 10.1186/s13036-016-0024-5     Document Type: Article
Times cited : (52)

References (31)
  • 1
    • 83955163721 scopus 로고    scopus 로고
    • Designing biological systems: systems engineering meets synthetic biology
    • Rollie S, Mangold M, Sundmacher K. Designing biological systems: systems engineering meets synthetic biology. Chem Eng Sci. 2012;69(1):1-29.
    • (2012) Chem Eng Sci , vol.69 , Issue.1 , pp. 1-29
    • Rollie, S.1    Mangold, M.2    Sundmacher, K.3
  • 2
    • 84902159136 scopus 로고    scopus 로고
    • The Synthetic Biology Open Language (SBOL) provides a community standard for communicating designs in synthetic biology
    • Galdzicki M, Clancy KP, Oberortner E, Pocock M, Quinn JY, Rodriguez CA, et al. The Synthetic Biology Open Language (SBOL) provides a community standard for communicating designs in synthetic biology. Nat Biotechnol. 2014;32(6):545-50.
    • (2014) Nat Biotechnol , vol.32 , Issue.6 , pp. 545-550
    • Galdzicki, M.1    Clancy, K.P.2    Oberortner, E.3    Pocock, M.4    Quinn, J.Y.5    Rodriguez, C.A.6
  • 3
    • 84875157880 scopus 로고    scopus 로고
    • The fusion of biology, computer science, and engineering: towards efficient and successful synthetic biology
    • Linshiz G, Goldberg A, Konry T, Hillson NJ. The fusion of biology, computer science, and engineering: towards efficient and successful synthetic biology. Perspect Biol Med. 2012;55(4):503-20.
    • (2012) Perspect Biol Med , vol.55 , Issue.4 , pp. 503-520
    • Linshiz, G.1    Goldberg, A.2    Konry, T.3    Hillson, N.J.4
  • 5
    • 84897149238 scopus 로고    scopus 로고
    • Integrating biological redesign: where synthetic biology came from and where it needs to go
    • Way JC, Collins JJ, Keasling JD, Silver PA. Integrating biological redesign: where synthetic biology came from and where it needs to go. Cell. 2014;157(1):151-61.
    • (2014) Cell , vol.157 , Issue.1 , pp. 151-161
    • Way, J.C.1    Collins, J.J.2    Keasling, J.D.3    Silver, P.A.4
  • 7
    • 77952527887 scopus 로고    scopus 로고
    • Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
    • Mark D, Haeberle S, Roth G, von Stetten F, Zengerle R. Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications. Chem Soc Rev. 2010;39(3):1153-82.
    • (2010) Chem Soc Rev , vol.39 , Issue.3 , pp. 1153-1182
    • Mark, D.1    Haeberle, S.2    Roth, G.3    Stetten, F.4    Zengerle, R.5
  • 8
    • 77956650346 scopus 로고    scopus 로고
    • Microfluidic approaches for systems and synthetic biology
    • Szita N, Polizzi K, Jaccard N, Baganz F. Microfluidic approaches for systems and synthetic biology. Curr Opin Biotechnol. 2010;21(4):517-23.
    • (2010) Curr Opin Biotechnol , vol.21 , Issue.4 , pp. 517-523
    • Szita, N.1    Polizzi, K.2    Jaccard, N.3    Baganz, F.4
  • 10
    • 78650177565 scopus 로고    scopus 로고
    • Microvalve enabled digital microfluidic systems for high performance biochemical and genetic analysis
    • Jensen EC, Zeng Y, Kim J, Mathies RA. Microvalve enabled digital microfluidic systems for high performance biochemical and genetic analysis. Jala. 2010;15(6):455-63.
    • (2010) Jala , vol.15 , Issue.6 , pp. 455-463
    • Jensen, E.C.1    Zeng, Y.2    Kim, J.3    Mathies, R.A.4
  • 11
    • 84863381095 scopus 로고    scopus 로고
    • Lifting gate polydimethylsiloxane microvalves and pumps for microfluidic control
    • Kim J, Kang M, Jensen EC, Mathies RA. Lifting gate polydimethylsiloxane microvalves and pumps for microfluidic control. Anal Chem. 2012;84(4):2067-71.
    • (2012) Anal Chem , vol.84 , Issue.4 , pp. 2067-2071
    • Kim, J.1    Kang, M.2    Jensen, E.C.3    Mathies, R.A.4
  • 12
    • 77949378006 scopus 로고    scopus 로고
    • A digital microfluidic platform for the automation of quantitative biomolecular assays
    • Jensen EC, Bhat BP, Mathies RA. A digital microfluidic platform for the automation of quantitative biomolecular assays. Lab Chip. 2010;10(6):685-91.
    • (2010) Lab Chip , vol.10 , Issue.6 , pp. 685-691
    • Jensen, E.C.1    Bhat, B.P.2    Mathies, R.A.3
  • 13
    • 84870938177 scopus 로고    scopus 로고
    • Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing
    • Jensen EC, Stockton AM, Chiesl TN, Kim J, Bera A, Mathies RA. Digitally programmable microfluidic automaton for multiscale combinatorial mixing and sample processing. Lab Chip. 2013;13(2):288-96.
    • (2013) Lab Chip , vol.13 , Issue.2 , pp. 288-296
    • Jensen, E.C.1    Stockton, A.M.2    Chiesl, T.N.3    Kim, J.4    Bera, A.5    Mathies, R.A.6
  • 14
    • 84882715808 scopus 로고    scopus 로고
    • Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer
    • Kim J, Jensen EC, Stockton AM, Mathies RA. Universal microfluidic automaton for autonomous sample processing: application to the Mars Organic Analyzer. Anal Chem. 2013;85(16):7682-8.
    • (2013) Anal Chem , vol.85 , Issue.16 , pp. 7682-7688
    • Kim, J.1    Jensen, E.C.2    Stockton, A.M.3    Mathies, R.A.4
  • 15
    • 33745685151 scopus 로고    scopus 로고
    • Development and multiplexed control of latching pneumatic valves using microfluidic logical structures
    • Grover WH, Ivester RH, Jensen EC, Mathies RA. Development and multiplexed control of latching pneumatic valves using microfluidic logical structures. Lab Chip. 2006;6(5):623-31.
    • (2006) Lab Chip , vol.6 , Issue.5 , pp. 623-631
    • Grover, W.H.1    Ivester, R.H.2    Jensen, E.C.3    Mathies, R.A.4
  • 18
    • 84900032261 scopus 로고    scopus 로고
    • Narrowing the gap between the promise and reality of polyketide synthases as a synthetic biology platform
    • Poust S, Hagen A, Katz L, Keasling JD. Narrowing the gap between the promise and reality of polyketide synthases as a synthetic biology platform. Curr Opin Biotechnol. 2014;30:32-9.
    • (2014) Curr Opin Biotechnol , vol.30 , pp. 32-39
    • Poust, S.1    Hagen, A.2    Katz, L.3    Keasling, J.D.4
  • 20
    • 56649114274 scopus 로고    scopus 로고
    • A one pot, one step, precision cloning method with high throughput capability
    • Engler C, Kandzia R, Marillonnet S. A one pot, one step, precision cloning method with high throughput capability. Plos One. 2008;3(11):e3647.
    • (2008) Plos One , vol.3 , Issue.11 , pp. e3647
    • Engler, C.1    Kandzia, R.2    Marillonnet, S.3
  • 22
    • 65849183178 scopus 로고    scopus 로고
    • Golden gate shuffling: a one-pot DNA shuffling method based on type IIs restriction enzymes
    • Engler C, Gruetzner R, Kandzia R, Marillonnet S. Golden gate shuffling: a one-pot DNA shuffling method based on type IIs restriction enzymes. Plos One. 2009;4(5):e5553.
    • (2009) Plos One , vol.4 , Issue.5 , pp. e5553
    • Engler, C.1    Gruetzner, R.2    Kandzia, R.3    Marillonnet, S.4
  • 25
    • 84903144112 scopus 로고    scopus 로고
    • Correlation analysis of targeted proteins and metabolites to assess and engineer microbial isopentenol production
    • George KW, Chen A, Jain A, Batth TS, Baidoo EE, Wang G, et al. Correlation analysis of targeted proteins and metabolites to assess and engineer microbial isopentenol production. Biotechnol Bioeng. 2014;111(8):1648-58.
    • (2014) Biotechnol Bioeng , vol.111 , Issue.8 , pp. 1648-1658
    • George, K.W.1    Chen, A.2    Jain, A.3    Batth, T.S.4    Baidoo, E.E.5    Wang, G.6
  • 26
    • 2942554938 scopus 로고    scopus 로고
    • Comparison of three colorimetric reagents in the determination of methanol with alcohol oxidase. Application to the assay of pectin methylesterase
    • Anthon GE, Barrett DM. Comparison of three colorimetric reagents in the determination of methanol with alcohol oxidase. Application to the assay of pectin methylesterase. J Agric Food Chem. 2004;52(12):3749-53.
    • (2004) J Agric Food Chem , vol.52 , Issue.12 , pp. 3749-3753
    • Anthon, G.E.1    Barrett, D.M.2
  • 27
    • 3042666256 scopus 로고    scopus 로고
    • MUSCLE: multiple sequence alignment with high accuracy and high throughput
    • Edgar RC. MUSCLE: multiple sequence alignment with high accuracy and high throughput. Nucleic Acids Res. 2004;32(5):1792-7.
    • (2004) Nucleic Acids Res , vol.32 , Issue.5 , pp. 1792-1797
    • Edgar, R.C.1
  • 28
  • 29
    • 0034274870 scopus 로고    scopus 로고
    • An open graph visualization system and its applications to software engineering
    • Gansner ER, North SC. An open graph visualization system and its applications to software engineering. Softw Pract Exper. 2000;30(11):1203-33.
    • (2000) Softw Pract Exper , vol.30 , Issue.11 , pp. 1203-1233
    • Gansner, E.R.1    North, S.C.2
  • 30
    • 85066366103 scopus 로고    scopus 로고
    • Canviz. Available from: https://code.google.com/p/canviz/.
  • 31
    • 84867488931 scopus 로고    scopus 로고
    • Design, implementation and practice of JBEI-ICE: an open source biological part registry platform and tools
    • Ham TS, Dmytriv Z, Plahar H, Chen J, Hillson NJ, Keasling JD. Design, implementation and practice of JBEI-ICE: an open source biological part registry platform and tools. Nucleic Acids Res. 2012;40(18):e141.
    • (2012) Nucleic Acids Res , vol.40 , Issue.18 , pp. e141
    • Ham, T.S.1    Dmytriv, Z.2    Plahar, H.3    Chen, J.4    Hillson, N.J.5    Keasling, J.D.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.