메뉴 건너뛰기




Volumn 1205, Issue , 1997, Pages 213-222

3d multi-scale line filter for segmentation and visualization of curvilinear structures in medical images

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER VISION; COMPUTERIZED TOMOGRAPHY; EIGENVALUES AND EIGENFUNCTIONS; IMAGE ENHANCEMENT; IMAGE SEGMENTATION; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGE PROCESSING; MEDICAL ROBOTICS; MEDICINE; RESPIRATORY SYSTEM; ROBOTICS; SURGERY; VIRTUAL REALITY; VISUALIZATION; VOLUME RENDERING;

EID: 84956673260     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/bfb0029240     Document Type: Conference Paper
Times cited : (241)

References (12)
  • 2
    • 0026961614 scopus 로고
    • Local Filtering and Global Optimisation Methods for 3D Magnetic Resonance Angiography (MRA) Image Enhancement
    • D. Vandermeulen, D. Delaere, P. Suetens, et al.: Local Filtering and Global Optimisation Methods for 3D Magnetic Resonance Angiography (MRA) Image Enhancement, Proc. VBC'92, pp.274-288 (1992).
    • (1992) Proc. VBC'92 , pp. 274-288
    • Vandermeulen, D.1    Delaere, D.2    Suetens, P.3
  • 4
    • 0029267052 scopus 로고
    • Vessel Enhancement Filtering m Three dimensional MR Angiography
    • Y. P. Du, D. L. Parker, and W. L. Davis: Vessel Enhancement Filtering m Three dimensional MR Angiography, Journal of Magnetic Resonance Imaging, Vol.5, No.2, pp.151-157 (1995).
    • (1995) Journal of Magnetic Resonance Imaging , vol.5 , Issue.2 , pp. 151-157
    • Du, Y.P.1    Parker, D.L.2    Davis, W.L.3
  • 5
    • 84981727385 scopus 로고
    • Automated Extraction and Visualization of Bronchus from 3D CT Images of Lung
    • K. Mori, J. Hasegawa, J. Toriwaki, et al.: Automated Extraction and Visualization of Bronchus from 3D CT Images of Lung, Proc. CVRMed'95, pp.549-554 (1995).
    • (1995) Proc. Cvrmed'95 , pp. 549-554
    • Mori, K.1    Hasegawa, J.2    Toriwaki, J.3
  • 6
    • 0026492416 scopus 로고
    • Impact of Section Doubling on MR Angiography
    • N. M. Hylton, I. Simovsky, A. J. Li, et al.: Impact of Section Doubling on MR Angiography, Radiology, Vol.185, No.3, pp.899-902 (1992).
    • (1992) Radiology , vol.185 , Issue.3 , pp. 899-902
    • Hylton, N.M.1    Simovsky, I.2    Li, A.J.3
  • 7
    • 0028509723 scopus 로고
    • Reduction of Partial Volume Artifacts with Zero-filled Interpolation in Three-dimensional MR Angiography
    • Y. P. Du, D. L. Parker, W. L. Davis, et al.: Reduction of Partial Volume Artifacts with Zero-filled Interpolation in Three-dimensional MR Angiography, Journal of Magnetic Resonance Imaging, Vol.4, No.5, pp.733-741 (1995).
    • (1995) Journal of Magnetic Resonance Imaging , vol.4 , Issue.5 , pp. 733-741
    • Du, Y.P.1    Parker, D.L.2    Davis, W.L.3
  • 8
    • 0029233647 scopus 로고
    • Multiscale Detection of Curvilinear Strutures in 2-D and 3-D Image Data
    • T. M. Koller, G. Gerig, G. Szekely, et al.: Multiscale Detection of Curvilinear Strutures in 2-D and 3-D Image Data, Proc. ICCV'95, pp.864-869 (1995).
    • (1995) Proc. ICCV'95 , pp. 864-869
    • Koller, T.M.1    Gerig, G.2    Szekely, G.3
  • 9
    • 79952741108 scopus 로고
    • : Measuring Microcirculation Using Spatiotem-' poral Image Analysis
    • Y Sato J Chen, S. Y. amamoto, et al.: Measuring Microcirculation Using Spatiotem-' poral Image Analysis, Proc. CVRMed'95, pp.302-308 (1995).
    • (1995) Proc. Cvrmed'95 , pp. 302-308
    • Sato J Chen, Y.1    Amamoto, S.Y.2
  • 11
    • 85027175346 scopus 로고
    • Fast Volume Rendering Using a Shear-Warp Factonzation of the Viewing Transform
    • P Lacroute and M. Levoy. Fast Volume Rendering Using a Shear-Warp Factonzation of the Viewing Transform, Proc. SIGGRAPH'94, pp.451-458 (1994).
    • (1994) Proc. SIGGRAPH'94 , pp. 451-458
    • Lacroute, P.1    Levoy, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.