Volumn 90, Issue , 2015, Pages 1994-2005

Reducing water usage with rotary regenerative gas/gas heat exchangers in natural gas-fired power plants with post-combustion carbon capture

Author keywords

Combined cycle gas turbine; Dry air cooled system; Exhaust gas recirculation; Post combustion carbon capture; Regenerative rotary heat exchanger

Indexed keywords

ABSORPTION COOLING; CARBON CAPTURE; COMBUSTION; COOLING; COOLING SYSTEMS; COOLING WATER; EXHAUST GAS RECIRCULATION; FLUE GASES; FOSSIL FUEL POWER PLANTS; GAS PLANTS; GAS TURBINES; GASES; HEAT EXCHANGERS; IONIZATION OF GASES; RIVERS;

EID: 84954369662     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2015.07.032     Document Type: Article
Times cited : (19)

References (23)
  • 3
    • 77958470467 scopus 로고    scopus 로고
    • Performance and cost of wet and dry cooling systems for pulverized coal power plants with and without carbon capture and storage
    • Zhai H, Rubin ES. Performance and cost of wet and dry cooling systems for pulverized coal power plants with and without carbon capture and storage. Energy Policy 2010;38:5653-60.
    • (2010) Energy Policy , vol.38 , pp. 5653-5660
    • Zhai, H.1    Rubin, E.S.2
  • 4
    • 79953892747 scopus 로고    scopus 로고
    • Water use at pulverized coal power plants with post-combustion carbon capture and storage
    • Zhai H, Rubin ES, Versteeg PL. Water use at pulverized coal power plants with post-combustion carbon capture and storage. Environ Sci Technol 2011;45: 2479-85.
    • (2011) Environ Sci Technol , vol.45 , pp. 2479-2485
    • Zhai, H.1    Rubin, E.S.2    Versteeg, P.L.3
  • 5
    • 84898461050 scopus 로고    scopus 로고
    • Electricity generation and cooling water use: UK pathways to 2050
    • Byers EA, Hall JW, Amezaga JM. Electricity generation and cooling water use: UK pathways to 2050. Glob Environ Change 2014;25:16-30.
    • (2014) Glob Environ Change , vol.25 , pp. 16-30
    • Byers, E.A.1    Hall, J.W.2    Amezaga, J.M.3
  • 6
    • 84922942858 scopus 로고    scopus 로고
    • Report, Cheltenham, UK
    • 2 capture. Report 2010/8, Cheltenham, UK. 2011.
    • (2011) 2 capture
  • 7
    • 84871832935 scopus 로고    scopus 로고
    • The water implications of generating electricity: water use across the United States based on different electricity pathways through 2050
    • Macknick J, Sattler S, Averyt K, Clemmer S, Rogers J. The water implications of generating electricity: water use across the United States based on different electricity pathways through 2050. Environ Res Lett 2012:1-10. 7-045803.
    • (2012) Environ Res Lett , pp. 1-10
    • Macknick, J.1    Sattler, S.2    Averyt, K.3    Clemmer, S.4    Rogers, J.5
  • 10
    • 77952672609 scopus 로고    scopus 로고
    • Maintaining a neutral water balance in a 450 MWe NGCC-CCS power system with post combustion carbon dioxide capture amine at offshore operation
    • Kvamsdal HM, Hetland J, Haugen G, Svendsen HF, Major F, Karstad V, et al. Maintaining a neutral water balance in a 450 MWe NGCC-CCS power system with post combustion carbon dioxide capture amine at offshore operation. Int J Greenh Gas Control 2010;4:613-22.
    • (2010) Int J Greenh Gas Control , vol.4 , pp. 613-622
    • Kvamsdal, H.M.1    Hetland, J.2    Haugen, G.3    Svendsen, H.F.4    Major, F.5    Karstad, V.6
  • 14
    • 84855180738 scopus 로고    scopus 로고
    • 2 capture by reactive absorption: pilot plant description and results of systematic studies with MEA
    • 2 capture by reactive absorption: pilot plant description and results of systematic studies with MEA. Int J Greenh Gas Control 2012;6:84-112.
    • (2012) Int J Greenh Gas Control , vol.6 , pp. 84-112
    • Notz, R.1    Mangalapally, H.P.2    Hasse, H.3
  • 15
    • 85019508546 scopus 로고    scopus 로고
    • ROAD CCS non-confidential FEED study report: special report for the Global Carbon Capture and Storage Institute
    • Huizeling E, Van der Weijde G. ROAD CCS non-confidential FEED study report: special report for the Global Carbon Capture and Storage Institute. 2011.
    • (2011)
    • Huizeling, E.1    Van der Weijde, G.2
  • 16
    • 77955321032 scopus 로고    scopus 로고
    • Application of exhaust gas recirculation in a DLN F-Class combustion system for postcombustion carbon capture
    • ElKady AM, Evulet A, Brand A. Application of exhaust gas recirculation in a DLN F-Class combustion system for postcombustion carbon capture. J Eng Gas Turbine Power 2009;131:1-6. 034505.
    • (2009) J Eng Gas Turbine Power , vol.131 , pp. 1-6
    • ElKady, A.M.1    Evulet, A.2    Brand, A.3
  • 18
    • 25144465911 scopus 로고    scopus 로고
    • Report PH4/33, Cheltenham, UK
    • 2. 2004. Report PH4/33, Cheltenham, UK.
    • (2004) 2
  • 19
  • 22
    • 84870488065 scopus 로고    scopus 로고
    • CESAR e project 7th Frame Work Programme. Collaborative Project e GA No. 213569
    • 2 capture technologies. 2011. CESAR e project 7th Frame Work Programme. Collaborative Project e GA No. 213569.
    • (2011) 2 capture technologies
  • 23
    • 85019537236 scopus 로고    scopus 로고
    • HJR_PC_B_01 preheaters: use of gasegas preheater performance program V0201 20121119 (Internal document)
    • Howden. HJR_PC_B_01 preheaters: use of gasegas preheater performance program V0201 20121119 (Internal document). 2008.
    • (2008)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.