Volumn 56, Issue 1, 2016, Pages 153-159

Fat removal during cell salvage: An optimized program for a discontinuous autotransfusion device

Author keywords

[No Author keywords available]

Indexed keywords

ADIPOSE TISSUE; APHERESIS; BLOOD AUTOTRANSFUSION; BLOOD SALVAGE; DEVICES; EVALUATION STUDY; HUMAN; PROCEDURES;

EID: 84954365135     PISSN: 00411132     EISSN: 15372995     Source Type: Journal    
DOI: 10.1111/trf.13286     Document Type: Article
Times cited : (7)

References (17)
  • 1
    • 84936989271 scopus 로고    scopus 로고
    • Fat removal during cell salvage: A comparison of four different cell salvage devices
    • Seyfried TF, Haas L, Gruber M, et al., Fat removal during cell salvage: a comparison of four different cell salvage devices. Transfusion 2015; 55: 1637-43.
    • (2015) Transfusion , vol.55 , pp. 1637-1643
    • Seyfried, T.F.1    Haas, L.2    Gruber, M.3
  • 2
    • 0030735245 scopus 로고    scopus 로고
    • Fat elimination during intraoperative autotransfusion: An in vitro investigation
    • Booke M, Fobker M, Fingerhut D, et al., Fat elimination during intraoperative autotransfusion: an in vitro investigation. Anesth Analg 1997; 85: 959-62.
    • (1997) Anesth Analg , vol.85 , pp. 959-962
    • Booke, M.1    Fobker, M.2    Fingerhut, D.3
  • 3
    • 0035140524 scopus 로고    scopus 로고
    • Fat elimination from autologous blood
    • Booke M, Van Aken H, Storm M, et al., Fat elimination from autologous blood. Anesth Analg 2001; 92: 341-3.
    • (2001) Anesth Analg , vol.92 , pp. 341-343
    • Booke, M.1    Van Aken, H.2    Storm, M.3
  • 4
    • 2342612717 scopus 로고    scopus 로고
    • Contaminating fat in pericardial suction blood: A clinical, technical and scientific challenge
    • Engström KG., Contaminating fat in pericardial suction blood: a clinical, technical and scientific challenge. Perfusion 2004; 19 Suppl 1: S21-31.
    • (2004) Perfusion , vol.19 , pp. S21-S31
    • Engström, K.G.1
  • 5
    • 0037273280 scopus 로고    scopus 로고
    • The embolic potential of liquid fat in pericardial suction blood, and its elimination
    • Engström KG., The embolic potential of liquid fat in pericardial suction blood, and its elimination. Perfusion 2003; 18 Suppl 1: 69-74.
    • (2003) Perfusion , vol.18 , pp. 69-74
    • Engström, K.G.1
  • 6
    • 0036365396 scopus 로고    scopus 로고
    • Detection removal of fat particles from postoperative salvaged blood in orthopaedic surgery
    • Ramírez G, Romero A, García-Vallejo JJ, et al., Detection removal of fat particles from postoperative salvaged blood in orthopaedic surgery. Transfusion 2002; 42: 66-75.
    • (2002) Transfusion , vol.42 , pp. 66-75
    • Ramírez, G.1    Romero, A.2    García-Vallejo, J.J.3
  • 7
    • 84877719413 scopus 로고    scopus 로고
    • Washing of banked blood by three different blood salvage devices
    • Gruber M, Breu A, Frauendorf M, et al., Washing of banked blood by three different blood salvage devices. Transfusion 2013; 53: 1001-9.
    • (2013) Transfusion , vol.53 , pp. 1001-1009
    • Gruber, M.1    Breu, A.2    Frauendorf, M.3
  • 8
    • 84908488772 scopus 로고    scopus 로고
    • Processing of small volumes in blood salvage devices
    • Seyfried T, Breu A, Gruber M, et al., Processing of small volumes in blood salvage devices. Transfusion 2014; 54: 2775-81.
    • (2014) Transfusion , vol.54 , pp. 2775-2781
    • Seyfried, T.1    Breu, A.2    Gruber, M.3
  • 9
    • 70449427631 scopus 로고    scopus 로고
    • Cardiorespiratory effects of venous lipid micro embolization in an experimental model of mediastinal shed blood reinfusion
    • Eyjolfsson A, Plaza I, Brondén B, et al., Cardiorespiratory effects of venous lipid micro embolization in an experimental model of mediastinal shed blood reinfusion. J Cardiothorac Surg 2009; 4: 48.
    • (2009) J Cardiothorac Surg , vol.4 , pp. 48
    • Eyjolfsson, A.1    Plaza, I.2    Brondén, B.3
  • 11
    • 33745221164 scopus 로고    scopus 로고
    • Randomized controlled trial of pericardial blood processing with a cell-saving device on neurologic markers in elderly patients undergoing coronary artery bypass graft surgery
    • Carrier M, Denault A, Lavoie J, et al., Randomized controlled trial of pericardial blood processing with a cell-saving device on neurologic markers in elderly patients undergoing coronary artery bypass graft surgery. Ann Thorac Surg 2006; 82: 51-5.
    • (2006) Ann Thorac Surg , vol.82 , pp. 51-55
    • Carrier, M.1    Denault, A.2    Lavoie, J.3
  • 12
    • 0037384701 scopus 로고    scopus 로고
    • A prospective randomised comparison of cardiotomy suction and cell saver for recycling shed blood during cardiac surgery
    • Jewell AE, Akowuah EF, Suvarna SK, et al., A prospective randomised comparison of cardiotomy suction and cell saver for recycling shed blood during cardiac surgery. Eur J Cardiothorac Surg 2003; 23: 633-6.
    • (2003) Eur J Cardiothorac Surg , vol.23 , pp. 633-636
    • Jewell, A.E.1    Akowuah, E.F.2    Suvarna, S.K.3
  • 13
    • 0033790341 scopus 로고    scopus 로고
    • Processing scavenged blood with a cell saver reduces cerebral lipid microembolization
    • Kincaid EH, Jones TJ, Stump DA, et al., Processing scavenged blood with a cell saver reduces cerebral lipid microembolization. Ann Thorac Surg 2000; 70: 1296-300.
    • (2000) Ann Thorac Surg , vol.70 , pp. 1296-1300
    • Kincaid, E.H.1    Jones, T.J.2    Stump, D.A.3
  • 14
    • 37349126990 scopus 로고    scopus 로고
    • Continuous-flow cell saver reduces cognitive decline in elderly patients after coronary bypass surgery
    • Djaiani G, Fedorko L, Borger MA, et al., Continuous-flow cell saver reduces cognitive decline in elderly patients after coronary bypass surgery. Circulation 2007; 116: 1888-95.
    • (2007) Circulation , vol.116 , pp. 1888-1895
    • Djaiani, G.1    Fedorko, L.2    Borger, M.A.3
  • 15
    • 33744740981 scopus 로고    scopus 로고
    • Clinical efficacy and biocompatibility of three different leukocyte and fat removal filters during cardiac surgery
    • de Vries AJ, Vermeijden WJ, Gu YJ, et al., Clinical efficacy and biocompatibility of three different leukocyte and fat removal filters during cardiac surgery. Artif Organs 2006; 30: 452-7.
    • (2006) Artif Organs , vol.30 , pp. 452-457
    • De Vries, A.J.1    Vermeijden, W.J.2    Gu, Y.J.3
  • 16
    • 0036082799 scopus 로고    scopus 로고
    • Study of five cell salvage machines in coronary artery surgery
    • Burman JF, Westlake AS, Davidson SJ, et al., Study of five cell salvage machines in coronary artery surgery. Transfus Med 2002; 12: 173-9.
    • (2002) Transfus Med , vol.12 , pp. 173-179
    • Burman, J.F.1    Westlake, A.S.2    Davidson, S.J.3
  • 17
    • 0036064518 scopus 로고    scopus 로고
    • Proposal for internal quality management in intra- and postoperative blood salvage
    • Hansen E, Altmeppen J., Proposal for internal quality management in intra- and postoperative blood salvage. Infus Ther Transfus Med 2002; 29: 147-50.
    • (2002) Infus Ther Transfus Med , vol.29 , pp. 147-150
    • Hansen, E.1    Altmeppen, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.