메뉴 건너뛰기




Volumn , Issue , 2000, Pages

Estimating the Magnitude and Phase Response of a 50 GHz Sampling Oscilloscope Using the "Nose-to-Nose" Method

Author keywords

[No Author keywords available]

Indexed keywords

CALIBRATION; SCATTERING PARAMETERS;

EID: 84954134986     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ARFTG.2000.327397     Document Type: Conference Paper
Times cited : (48)

References (9)
  • 1
    • 0028422178 scopus 로고
    • Individual characterization of broadband sampling oscilloscopes with a 'nose-to-nose' calibration procedure
    • J. Verspecht and K. Rush, "Individual characterization of broadband sampling oscilloscopes with a 'nose-to-nose' calibration procedure," IEEE Trans. Instrum. Meas., vol. 43, pp. 347-354, 1994.
    • (1994) IEEE Trans. Instrum. Meas. , vol.43 , pp. 347-354
    • Verspecht, J.1    Rush, K.2
  • 2
    • 0029484916 scopus 로고
    • Broadband sampling oscilloscope characterization with the nose-to-nose calibration procedure: A theoretical and practical analysis
    • J. Verspecht, "Broadband sampling oscilloscope characterization with the nose-to-nose calibration procedure: a theoretical and practical analysis," IEEE Trans. Instrum. Meas., vol. 44, pp. 991-997, 1995.
    • (1995) IEEE Trans. Instrum. Meas. , vol.44 , pp. 991-997
    • Verspecht, J.1
  • 5
    • 0033325346 scopus 로고    scopus 로고
    • Least-squares estimation of time-base distortion of sampling oscilloscopes
    • C. M. Wang, P. D. Hale, and K. J. Coakley, "Least-squares estimation of time-base distortion of sampling oscilloscopes," IEEE Trans. Instrum. Meas., vol. 48, pp.1324-1332, 1999.
    • (1999) IEEE Trans. Instrum. Meas. , vol.48 , pp. 1324-1332
    • Wang, C.M.1    Hale, P.D.2    Coakley, K.J.3
  • 6
    • 0032180714 scopus 로고    scopus 로고
    • Signal reconstruction for nonequidistant finite length sample sets: A KIS approach
    • Y. Rolan, J. Schoukens, and G. Vandersteen, "Signal reconstruction for nonequidistant finite length sample sets: a KIS approach," IEEE Trans. Instrum. Meas., vol. 47, pp. 1046-1052, 1998.
    • (1998) IEEE Trans. Instrum. Meas. , vol.47 , pp. 1046-1052
    • Rolan, Y.1    Schoukens, J.2    Vandersteen, G.3
  • 7
    • 0020101127 scopus 로고
    • The measurement and deconvolution of time jitter in equivalent-time waveform samplers
    • W. L. Gans, "The measurement and deconvolution of time jitter in equivalent-time waveform samplers," IEEE Instrum. Meas., vol. 32, pp 126-133, 1983.
    • (1983) IEEE Instrum. Meas. , vol.32 , pp. 126-133
    • Gans, W.L.1
  • 9
    • 0031258624 scopus 로고    scopus 로고
    • A direct calibration method for measuring equivalent source mismatch
    • Oct
    • J. R. Juroshek, "A direct calibration method for measuring equivalent source mismatch," Microwave J., Oct. 1997, pp. 106-118.
    • (1997) Microwave J. , pp. 106-118
    • Juroshek, J.R.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.