메뉴 건너뛰기




Volumn 71, Issue 2, 2016, Pages 177-184

Evaluation of a novel Surgicric® cricothyroidotomy device for emergency tracheal access in a porcine model

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIST; ANESTHETIC EQUIPMENT; ANIMAL TISSUE; ARTICLE; BOUGIE; CONTROLLED STUDY; DATA ANALYSIS SOFTWARE; EMERGENCY SURGERY; NONHUMAN; PORCINE MODEL; SCALPEL; SIMULATOR; TRACHEA INJURY; TRACHEAL DILATOR; TRACHEAL HOOK; TRACHEOSTOMY; TRACHEOTOMY; AIRWAY OBSTRUCTION; ANIMAL; ANIMAL MODEL; CRICOID CARTILAGE; CROSSOVER PROCEDURE; EMERGENCY; ENDOTRACHEAL INTUBATION; EQUIPMENT DESIGN; PIG; PROCEDURES; SURGERY; TRACHEA;

EID: 84954064288     PISSN: 00032409     EISSN: 13652044     Source Type: Journal    
DOI: 10.1111/anae.13275     Document Type: Article
Times cited : (18)

References (27)
  • 1
    • 79954538887 scopus 로고    scopus 로고
    • Major complications of airway management in the UK: Results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: Anaesthesia
    • Cook TM, Woodall N, Frerk C,. Major complications of airway management in the UK: results of the Fourth National Audit Project of the Royal College of Anaesthetists and the Difficult Airway Society. Part 1: anaesthesia. British Journal of Anaesthesia 2011; 106: 617-31.
    • (2011) British Journal of Anaesthesia , vol.106 , pp. 617-631
    • Cook, T.M.1    Woodall, N.2    Frerk, C.3
  • 2
    • 81155146129 scopus 로고    scopus 로고
    • Equipment and strategies for emergency tracheal access in the adult patient
    • Hamaekers AE, Henderson JJ,. Equipment and strategies for emergency tracheal access in the adult patient. Anaesthesia 2011; 66 (Suppl 2): 65-80.
    • (2011) Anaesthesia , vol.66 , pp. 65-80
    • Hamaekers, A.E.1    Henderson, J.J.2
  • 3
    • 0030059431 scopus 로고    scopus 로고
    • Failed emergency transtracheal ventilation through a 14-gauge intravenous catheter
    • Metz S, Parmet JL, Levitt JD,. Failed emergency transtracheal ventilation through a 14-gauge intravenous catheter. Journal of Clinical Anesthesia 1996; 8: 58-62.
    • (1996) Journal of Clinical Anesthesia , vol.8 , pp. 58-62
    • Metz, S.1    Parmet, J.L.2    Levitt, J.D.3
  • 4
    • 79952115334 scopus 로고    scopus 로고
    • Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model
    • Murphy C, Rooney SJ, Maharaj CH, Laffey JG, Harte BH,. Comparison of three cuffed emergency percutaneous cricothyroidotomy devices to conventional surgical cricothyroidotomy in a porcine model. British Journal of Anaesthesia 2011; 106: 57-64.
    • (2011) British Journal of Anaesthesia , vol.106 , pp. 57-64
    • Murphy, C.1    Rooney, S.J.2    Maharaj, C.H.3    Laffey, J.G.4    Harte, B.H.5
  • 5
    • 84954043133 scopus 로고    scopus 로고
    • Surgicric I VBM. (accessed 02/04/2012)
    • VBM. Surgicric I. http://www.vbm-medical.de/cms/files/p347-surgicric-i-gb-6.0-03.2013.pdf (accessed 02/04/2012).
  • 7
    • 77953554191 scopus 로고    scopus 로고
    • Cricothyrotomy technique using gum elastic bougie is faster than standard technique: A study of emergency medicine residents and medical students in an animal lab
    • Hill C, Reardon R, Joing S, Falvey D, Miner J,. Cricothyrotomy technique using gum elastic bougie is faster than standard technique: a study of emergency medicine residents and medical students in an animal lab. Academic Emergency Medicine 2010; 17: 666-9.
    • (2010) Academic Emergency Medicine , vol.17 , pp. 666-669
    • Hill, C.1    Reardon, R.2    Joing, S.3    Falvey, D.4    Miner, J.5
  • 10
    • 0033573147 scopus 로고    scopus 로고
    • A preclinical model for laryngeal transplantation: Anatomy and mucosal immunology of the porcine larynx
    • Gorti GK, Birchall MA, Haverson K, Macchiarini P, Bailey M,. A preclinical model for laryngeal transplantation: anatomy and mucosal immunology of the porcine larynx. Transplantation 1999; 68: 1638-42.
    • (1999) Transplantation , vol.68 , pp. 1638-1642
    • Gorti, G.K.1    Birchall, M.A.2    Haverson, K.3    Macchiarini, P.4    Bailey, M.5
  • 11
    • 56249113017 scopus 로고    scopus 로고
    • Comparison of manikin versus porcine models in cricothyrotomy procedure training
    • Cho J, Kang GH, Kim EC, et al., Comparison of manikin versus porcine models in cricothyrotomy procedure training. Emergency Medicine Journal 2008; 25: 732-4.
    • (2008) Emergency Medicine Journal , vol.25 , pp. 732-734
    • Cho, J.1    Kang, G.H.2    Kim, E.C.3
  • 13
    • 84905656626 scopus 로고    scopus 로고
    • Observational study of the success rates of intubation and failed intubation airway rescue techniques in 7256 attempted intubations of trauma patients by pre-hospital physicians
    • Lockey D, Crewdson K, Weaver A, Davies G,. Observational study of the success rates of intubation and failed intubation airway rescue techniques in 7256 attempted intubations of trauma patients by pre-hospital physicians. British Journal of Anaesthesia 2014; 113: 220-5.
    • (2014) British Journal of Anaesthesia , vol.113 , pp. 220-225
    • Lockey, D.1    Crewdson, K.2    Weaver, A.3    Davies, G.4
  • 15
    • 0347285536 scopus 로고    scopus 로고
    • Comparison of four different emergency airway access equipment sets on a human patient simulator
    • Vadodaria BS, Gandhi SD, McIndoe AK,. Comparison of four different emergency airway access equipment sets on a human patient simulator. Anaesthesia 2004; 59: 73-9.
    • (2004) Anaesthesia , vol.59 , pp. 73-79
    • Vadodaria, B.S.1    Gandhi, S.D.2    McIndoe, A.K.3
  • 16
    • 33646687016 scopus 로고    scopus 로고
    • Surgical vs wire-guided cricothyroidotomy: A randomised crossover study of cuffed and uncuffed tracheal tube insertion
    • Sulaiman L, Tighe SQ, Nelson RA,. Surgical vs wire-guided cricothyroidotomy: a randomised crossover study of cuffed and uncuffed tracheal tube insertion. Anaesthesia 2006; 61: 565-70.
    • (2006) Anaesthesia , vol.61 , pp. 565-570
    • Sulaiman, L.1    Tighe, S.Q.2    Nelson, R.A.3
  • 17
    • 0034092832 scopus 로고    scopus 로고
    • Comparison of conventional surgical versus Seldinger technique emergency cricothyrotomy performed by inexperienced clinicians
    • Eisenburger P, Laczika K, List M, et al., Comparison of conventional surgical versus Seldinger technique emergency cricothyrotomy performed by inexperienced clinicians. Anesthesiology 2000; 92: 687-90.
    • (2000) Anesthesiology , vol.92 , pp. 687-690
    • Eisenburger, P.1    Laczika, K.2    List, M.3
  • 18
    • 19944427607 scopus 로고    scopus 로고
    • Evaluation of Seldinger technique emergency cricothyroidotomy versus standard surgical cricothyroidotomy in 200 cadavers
    • Schaumann N, Lorenz V, Schellongowski P, et al., Evaluation of Seldinger technique emergency cricothyroidotomy versus standard surgical cricothyroidotomy in 200 cadavers. Anesthesiology 2005; 102: 7-11.
    • (2005) Anesthesiology , vol.102 , pp. 7-11
    • Schaumann, N.1    Lorenz, V.2    Schellongowski, P.3
  • 20
    • 0032710513 scopus 로고    scopus 로고
    • A comparison of a novel cricothyrotomy device with a standard surgical cricothyrotomy technique
    • Bair AE, Sakles JC,. A comparison of a novel cricothyrotomy device with a standard surgical cricothyrotomy technique. Academic Emergency Medicine 1999; 6: 1172-4.
    • (1999) Academic Emergency Medicine , vol.6 , pp. 1172-1174
    • Bair, A.E.1    Sakles, J.C.2
  • 21
  • 22
    • 58149357013 scopus 로고    scopus 로고
    • Emergency cricothyrotomy-a comparative study of different techniques in human cadavers
    • Schober P, Hegemann MC, Schwarte LA, Loer SA, Noetges P,. Emergency cricothyrotomy-a comparative study of different techniques in human cadavers. Resuscitation 2009; 80: 204-9.
    • (2009) Resuscitation , vol.80 , pp. 204-209
    • Schober, P.1    Hegemann, M.C.2    Schwarte, L.A.3    Loer, S.A.4    Noetges, P.5
  • 23
    • 84928498829 scopus 로고    scopus 로고
    • Percutaneous emergency airway access; Prevention, preparation, technique and training
    • Kristensen MS, Teoh WH, Baker PA,. Percutaneous emergency airway access; prevention, preparation, technique and training. British Journal of Anaesthesia 2015; 114: 357-61.
    • (2015) British Journal of Anaesthesia , vol.114 , pp. 357-361
    • Kristensen, M.S.1    Teoh, W.H.2    Baker, P.A.3
  • 24
    • 31744436890 scopus 로고    scopus 로고
    • The classic laryngeal mask airway: A tried and tested airway. What now?
    • Cook TM,. The classic laryngeal mask airway: a tried and tested airway. What now? British Journal of Anaesthesia 2006; 96: 149-52.
    • (2006) British Journal of Anaesthesia , vol.96 , pp. 149-152
    • Cook, T.M.1
  • 25
    • 78650658494 scopus 로고    scopus 로고
    • Evaluation of airway equipment: Man or manikin?
    • Rai MR, Popat MT,. Evaluation of airway equipment: man or manikin? Anaesthesia 2011; 66: 1-3.
    • (2011) Anaesthesia , vol.66 , pp. 1-3
    • Rai, M.R.1    Popat, M.T.2
  • 26
    • 79960345145 scopus 로고    scopus 로고
    • The Difficult Airway Society 'ADEPT' guidance on selecting airway devices: The basis of a strategy for equipment evaluation
    • Pandit JJ, Popat MT, Cook TM, et al., The Difficult Airway Society 'ADEPT' guidance on selecting airway devices: the basis of a strategy for equipment evaluation. Anaesthesia 2011; 66: 726-37.
    • (2011) Anaesthesia , vol.66 , pp. 726-737
    • Pandit, J.J.1    Popat, M.T.2    Cook, T.M.3
  • 27
    • 84925556303 scopus 로고    scopus 로고
    • Rescuing the obese or burned airway: Are conventional training manikins adequate? A simulation study
    • Howes TE, Lobo CA, Kelly FE, Cook TM,. Rescuing the obese or burned airway: are conventional training manikins adequate? A simulation study. British Journal of Anaesthesia 2015; 114: 136-42.
    • (2015) British Journal of Anaesthesia , vol.114 , pp. 136-142
    • Howes, T.E.1    Lobo, C.A.2    Kelly, F.E.3    Cook, T.M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.