메뉴 건너뛰기




Volumn 125, Issue , 2016, Pages 373-380

Periodic theory of building integrated photovoltaic thermal (BiPVT) system

Author keywords

BiPVT (building integrated photovoltaic thermal) system; Building envelope; Passive building; Periodic theory

Indexed keywords

ATMOSPHERIC TEMPERATURE; FLOORS; FOURIER ANALYSIS; REINFORCED CONCRETE; ROOFS; THERMAL LOAD;

EID: 84953432346     PISSN: 0038092X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.solener.2015.12.028     Document Type: Article
Times cited : (38)

References (26)
  • 1
    • 84887572669 scopus 로고    scopus 로고
    • Stack ventilation in multi-storey atrium buildings: a dimensionless design approach
    • Acred A., Hunt G.R. Stack ventilation in multi-storey atrium buildings: a dimensionless design approach. Build. Environ. 2014, 72:44-52.
    • (2014) Build. Environ. , vol.72 , pp. 44-52
    • Acred, A.1    Hunt, G.R.2
  • 2
    • 79951948024 scopus 로고    scopus 로고
    • Life cycle cost assessment of building integrated photovoltaic thermal (BIPVT) systems
    • Agrawal B., Tiwari G. Life cycle cost assessment of building integrated photovoltaic thermal (BIPVT) systems. Energy Build. 2010, 42(9):1472-1481.
    • (2010) Energy Build. , vol.42 , Issue.9 , pp. 1472-1481
    • Agrawal, B.1    Tiwari, G.2
  • 3
    • 75149138434 scopus 로고    scopus 로고
    • Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions
    • Agrawal B., Tiwari G. Optimizing the energy and exergy of building integrated photovoltaic thermal (BIPVT) systems under cold climatic conditions. Appl Energy 2010, 87(2):417-426.
    • (2010) Appl Energy , vol.87 , Issue.2 , pp. 417-426
    • Agrawal, B.1    Tiwari, G.2
  • 4
    • 61849096067 scopus 로고    scopus 로고
    • Performance of a building integrated photovoltaic/thermal (BIPVT) solar collector
    • Anderson T.N., Duke M., Morrison G., Carson J.K. Performance of a building integrated photovoltaic/thermal (BIPVT) solar collector. Sol. Energy 2009, 83(4):445-455.
    • (2009) Sol. Energy , vol.83 , Issue.4 , pp. 445-455
    • Anderson, T.N.1    Duke, M.2    Morrison, G.3    Carson, J.K.4
  • 5
    • 0032210313 scopus 로고    scopus 로고
    • Effects of wall's insulation thickness and position on time lag and decrement factor
    • Asan H. Effects of wall's insulation thickness and position on time lag and decrement factor. Energy Build. 1998, 28(3):299-305.
    • (1998) Energy Build. , vol.28 , Issue.3 , pp. 299-305
    • Asan, H.1
  • 6
    • 0023862238 scopus 로고
    • Fourier analysis of daily solar radiation data in Spain
    • Baldasano J., Clar J., Berna A. Fourier analysis of daily solar radiation data in Spain. Sol. Energy 1988, 41(4):327-333.
    • (1988) Sol. Energy , vol.41 , Issue.4 , pp. 327-333
    • Baldasano, J.1    Clar, J.2    Berna, A.3
  • 7
    • 84892466198 scopus 로고    scopus 로고
    • A review of the performance of different ventilation and airflow distribution systems in buildings
    • Cao G., Awbi H., Yao R., Fan Y., Siren K., Kosonen R., Zhang J.J. A review of the performance of different ventilation and airflow distribution systems in buildings. Build. Environ. 2014, 73:171-186.
    • (2014) Build. Environ. , vol.73 , pp. 171-186
    • Cao, G.1    Awbi, H.2    Yao, R.3    Fan, Y.4    Siren, K.5    Kosonen, R.6    Zhang, J.J.7
  • 8
    • 58949090479 scopus 로고    scopus 로고
    • Analytical expression for electrical efficiency of PV/T hybrid air collector
    • Dubey S., Sandhu G., Tiwari G. Analytical expression for electrical efficiency of PV/T hybrid air collector. Appl. Energy 2009, 86(5):697-705.
    • (2009) Appl. Energy , vol.86 , Issue.5 , pp. 697-705
    • Dubey, S.1    Sandhu, G.2    Tiwari, G.3
  • 9
    • 13844320870 scopus 로고    scopus 로고
    • Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse
    • Ghosal M., Tiwari G., Das D., Pandey K. Modeling and comparative thermal performance of ground air collector and earth air heat exchanger for heating of greenhouse. Energy Build. 2005, 37(6):613-621.
    • (2005) Energy Build. , vol.37 , Issue.6 , pp. 613-621
    • Ghosal, M.1    Tiwari, G.2    Das, D.3    Pandey, K.4
  • 10
    • 84887058060 scopus 로고    scopus 로고
    • Efficiencies and improvement potential of building integrated photovoltaic thermal (BIPVT) system
    • Ibrahim A., Fudholi A., Sopian K., Othman M.Y., Ruslan M.H. Efficiencies and improvement potential of building integrated photovoltaic thermal (BIPVT) system. Energy Convers. Manage. 2014, 77:527-534.
    • (2014) Energy Convers. Manage. , vol.77 , pp. 527-534
    • Ibrahim, A.1    Fudholi, A.2    Sopian, K.3    Othman, M.Y.4    Ruslan, M.H.5
  • 11
    • 0019708340 scopus 로고
    • Periodic heat transfer and load levelling of heat flux through a PCCM thermal storage wall/roof in an air-conditioned building
    • Kaushik S., Sodha M., Bhardwaj S., Kaushik N. Periodic heat transfer and load levelling of heat flux through a PCCM thermal storage wall/roof in an air-conditioned building. Build. Environ. 1981, 16(2):99-107.
    • (1981) Build. Environ. , vol.16 , Issue.2 , pp. 99-107
    • Kaushik, S.1    Sodha, M.2    Bhardwaj, S.3    Kaushik, N.4
  • 12
    • 34548438950 scopus 로고    scopus 로고
    • Roof pond cooling of buildings in hot arid climates
    • Kharrufa S.N., Adil Y. Roof pond cooling of buildings in hot arid climates. Build. Environ. 2008, 43(1):82-89.
    • (2008) Build. Environ. , vol.43 , Issue.1 , pp. 82-89
    • Kharrufa, S.N.1    Adil, Y.2
  • 13
    • 84896771436 scopus 로고    scopus 로고
    • A simulation study of air-type building-integrated photovoltaic-thermal system
    • Kim J.-H., Kim J.-T. A simulation study of air-type building-integrated photovoltaic-thermal system. Energy Procedia 2012, 30:1016-1024.
    • (2012) Energy Procedia , vol.30 , pp. 1016-1024
    • Kim, J.-H.1    Kim, J.-T.2
  • 14
    • 84898992098 scopus 로고    scopus 로고
    • Experimental performance of heating system with building-integrated PVT (BIPVT) collector
    • Kim J.-H., Park S.-H., Kang J.-G., Kim J.-T. Experimental performance of heating system with building-integrated PVT (BIPVT) collector. Energy Procedia 2014, 48:1374-1384.
    • (2014) Energy Procedia , vol.48 , pp. 1374-1384
    • Kim, J.-H.1    Park, S.-H.2    Kang, J.-G.3    Kim, J.-T.4
  • 15
    • 84871812119 scopus 로고    scopus 로고
    • Determination of optimum insulation thickness based on cooling transmission load for building walls in a hot climate
    • Ozel M. Determination of optimum insulation thickness based on cooling transmission load for building walls in a hot climate. Energy Convers. Manage. 2013, 66:106-114.
    • (2013) Energy Convers. Manage. , vol.66 , pp. 106-114
    • Ozel, M.1
  • 16
    • 84865661632 scopus 로고    scopus 로고
    • Trombe walls: a review of opportunities and challenges in research and development
    • Saadatian O., Sopian K., Lim C., Asim N., Sulaiman M. Trombe walls: a review of opportunities and challenges in research and development. Renew. Sustain. Energy Rev. 2012, 16(8):6340-6351.
    • (2012) Renew. Sustain. Energy Rev. , vol.16 , Issue.8 , pp. 6340-6351
    • Saadatian, O.1    Sopian, K.2    Lim, C.3    Asim, N.4    Sulaiman, M.5
  • 19
    • 0018917080 scopus 로고
    • Periodic heat flux through a three layered slab
    • Sodha M., Tiwari G., Kaushik S. Periodic heat flux through a three layered slab. Int. J. Energy Res. 1980, 4(1):93-96.
    • (1980) Int. J. Energy Res. , vol.4 , Issue.1 , pp. 93-96
    • Sodha, M.1    Tiwari, G.2    Kaushik, S.3
  • 20
    • 0345375476 scopus 로고    scopus 로고
    • On thermal performance of an improved roof pond for cooling buildings
    • Tang R., Etzion Y. On thermal performance of an improved roof pond for cooling buildings. Build. Environ. 2004, 39(2):201-209.
    • (2004) Build. Environ. , vol.39 , Issue.2 , pp. 201-209
    • Tang, R.1    Etzion, Y.2
  • 22
    • 0020429308 scopus 로고
    • A review-cooling by water evaporation over roof
    • Tiwari G., Kumar A., Sodha M. A review-cooling by water evaporation over roof. Energy Convers Manage 1982, 22(2):143-153.
    • (1982) Energy Convers Manage , vol.22 , Issue.2 , pp. 143-153
    • Tiwari, G.1    Kumar, A.2    Sodha, M.3
  • 23
    • 84861699231 scopus 로고    scopus 로고
    • Energy and exergy analysis of a building integrated semitransparent photovoltaic thermal (BISPVT) system
    • Vats K., Tiwari G. Energy and exergy analysis of a building integrated semitransparent photovoltaic thermal (BISPVT) system. Appl. Energy 2012, 96:409-416.
    • (2012) Appl. Energy , vol.96 , pp. 409-416
    • Vats, K.1    Tiwari, G.2
  • 24
    • 84855252325 scopus 로고    scopus 로고
    • Performance evaluation of a building integrated semitransparent photovoltaic thermal system for roof and façade
    • Vats K., Tiwari G. Performance evaluation of a building integrated semitransparent photovoltaic thermal system for roof and façade. Energy Build. 2012, 45:211-218.
    • (2012) Energy Build. , vol.45 , pp. 211-218
    • Vats, K.1    Tiwari, G.2
  • 25
    • 84864398287 scopus 로고    scopus 로고
    • Effect of packing factor on the performance of a building integrated semitransparent photovoltaic thermal (BISPVT) system with air duct
    • Vats K., Tomar V., Tiwari G. Effect of packing factor on the performance of a building integrated semitransparent photovoltaic thermal (BISPVT) system with air duct. Energy Build. 2012, 53:159-165.
    • (2012) Energy Build. , vol.53 , pp. 159-165
    • Vats, K.1    Tomar, V.2    Tiwari, G.3
  • 26
    • 84899638018 scopus 로고    scopus 로고
    • A study of design options for a building integrated photovoltaic/thermal (BIPV/T) system with glazed air collector and multiple inlets
    • Yang T., Athienitis A.K. A study of design options for a building integrated photovoltaic/thermal (BIPV/T) system with glazed air collector and multiple inlets. Sol. Energy 2014, 104:82-92.
    • (2014) Sol. Energy , vol.104 , pp. 82-92
    • Yang, T.1    Athienitis, A.K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.