메뉴 건너뛰기




Volumn 2015-November, Issue , 2015, Pages 4089-4092

A more acceptable endoluminal implantation for remotely monitoring ingestible sensors anchored to the stomach wall

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; CAPSULE ENDOSCOPE; CAPSULE ENDOSCOPY; DEVICES; GASTRIC MUCOSA; HUMAN; IMAGING PHANTOM; PH; PHYSIOLOGIC MONITORING; PIG; SMARTPHONE; STOMACH FUNDUS; WIRELESS COMMUNICATION;

EID: 84953247791     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2015.7319293     Document Type: Conference Paper
Times cited : (5)

References (11)
  • 1
    • 84926501042 scopus 로고    scopus 로고
    • Innovations leading capsule endoscopy into the new frontier: Screening and therapy at home
    • H Ohta "Innovations Leading Capsule Endoscopy into the New Frontier: Screening and Therapy at Home" IEICE TRAN. COMMUN vol. E98-B NO. 4, pp. 526-534, 2015.
    • (2015) IEICE TRAN. COMMUN , vol.E98-B , Issue.4 , pp. 526-534
    • Ohta, H.1
  • 2
    • 84926511240 scopus 로고    scopus 로고
    • Technical feasibility of patient friendly screening and treatment to digestive disease by remote control robotic capsule endoscope via the Internet
    • Aug.
    • H Ohta, M Kawashima "Technical feasibility of patient friendly screening and treatment to digestive disease by remote control robotic capsule endoscope via the Internet, "36th annual Int. Conf. of IEEE on EMB, pp7001-7004, Aug. 2014.
    • (2014) 36th annual Int. Conf. of IEEE on EMB , pp. 7001-7004
    • Ohta, H.1    Kawashima, M.2
  • 3
    • 38849152825 scopus 로고    scopus 로고
    • An implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameter
    • P Valdastri, S Rossi, A Menciassi et al. " An implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameter, " Sensors and Actuators A142, pp. 369-378, 2008.
    • (2008) Sensors and Actuators A , vol.142 , pp. 369-378
    • Valdastri, P.1    Rossi, S.2    Menciassi, A.3
  • 4
    • 70349548147 scopus 로고    scopus 로고
    • Citric acid cycle biomimic on a carbon hydrate
    • D. Sokic Lazic, S. D. Minteer, "Citric acid cycle biomimic on a carbon hydrate, " Biosens Bioelectron 24, No. 4, pp. 945-750, 2008.
    • (2008) Biosens Bioelectron , vol.24 , Issue.4 , pp. 945-750
    • Sokic Lazic, D.1    Minteer, S.D.2
  • 5
    • 49549085268 scopus 로고    scopus 로고
    • Gastric-fluid-utilizing micro battery for micro medical devices
    • H Jimbo, H Miki "Gastric-fluid-utilizing micro battery for micro medical devices, " Sensors and actuators B 134, pp. 219-24, 2008.
    • (2008) Sensors and Actuators B , vol.134 , pp. 219-224
    • Jimbo, H.1    Miki, H.2
  • 6
    • 84888268007 scopus 로고    scopus 로고
    • Flexible and transparent gastric battery; Energy harvesting from gastric acid for endoscopy application
    • P Mostafalu, S Sonlusale Flexible and transparent gastric battery; Energy harvesting from gastric acid for endoscopy application, Biosensors and Bioelectronics 54, pp. 292-96, 2014.
    • (2014) Biosensors and Bioelectronics , vol.54 , pp. 292-296
    • Mostafalu, P.1    Sonlusale, S.2
  • 7
    • 84880801051 scopus 로고    scopus 로고
    • Development of enhanced piezoelectric energy harvester induced by human motion
    • Aug.
    • Y Minami, E Nakajima, "Development of enhanced piezoelectric energy harvester induced by human motion, " 34th annual Int. Conf. of IEEE on EMB, pp. 1627-1630, Aug. 2012.
    • (2012) 34th Annual Int. Conf. of IEEE on EMB , pp. 1627-1630
    • Minami, Y.1    Nakajima, E.2
  • 8
    • 84920507386 scopus 로고    scopus 로고
    • A 6. 14ua normally-off ECG-soc with noise tolerant heart rate extractor for wearable healthcare systems
    • Oct.
    • S Izumi, K Yamashita, M Nakano et al. "A 6. 14uA Normally-Off ECG-SoC with Noise Tolerant Heart Rate Extractor for Wearable Healthcare Systems, " Proc. of IEEE BioCAS, pp. 280-283, Oct. 2014
    • (2014) Proc. of IEEE BioCAS , pp. 280-283
    • Izumi, S.1    Yamashita, K.2    Nakano, M.3
  • 10
    • 84859509858 scopus 로고    scopus 로고
    • Conductive polymer combined silk fiber bundle for bioelectrical signal recording
    • e33689
    • S Tsukada, H. Nakashima, and K. Torimitsu, "Conductive polymer combined silk fiber bundle for bioelectrical signal recording, " PLoS ONE, Vol. 7, e33689, 2012.
    • (2012) PLoS ONE , vol.7
    • Tsukada, S.1    Nakashima, H.2    Torimitsu, K.3
  • 11
    • 84880899444 scopus 로고    scopus 로고
    • A survey on Intrabody communications for body area network applications
    • Aug 2013
    • M Seyedi, B Kibret, D. T. H. Lai, M Faulkner, "A survey on Intrabody communications for body area network applications" IEEE trans on BIOMED pp. 2067-2079, Vol. 60, No. 8, Aug 2013
    • IEEE Trans on BIOMED , vol.60 , Issue.8 , pp. 2067-2079
    • Seyedi, M.1    Kibret, B.2    Lai, D.T.H.3    Faulkner, M.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.