Frequency dependent voltage control by der units to improve power system frequency stability

Author keywords

Frequency stability; interconnected power system; primary frequency control; wind power generation

Indexed keywords

CONTROL SYSTEM STABILITY; ELECTRIC FAULT CURRENTS; ELECTRIC MACHINE CONTROL; ELECTRIC POWER GENERATION; ELECTRIC POWER SYSTEM CONTROL; ELECTRIC POWER SYSTEM INTERCONNECTION; ELECTRIC POWER SYSTEM STABILITY; ENERGY RESOURCES; FREQUENCY STABILITY; POWER CONTROL; REACTIVE POWER; SYSTEM STABILITY; VOLTAGE CONTROL; WIND POWER; WIND TURBINES;

EID: 84951309750     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/PTC.2015.7232349     Document Type: Conference Paper
Times cited : (8)

References (9)
  • 1
    • 67349262621 scopus 로고    scopus 로고
    • Dynamic contribution of DFlG-based wind plants to system frequency disturbances
    • May
    • M. Kayikci, J. V. Milanovic, "Dynamic Contribution of DFlG-Based Wind Plants to System Frequency Disturbances, " iEEE Transactions on Power System, vo1. 24, no. 2, pp. 859, 867, May 2009
    • (2009) IEEE Transactions on Power System , vol.24 , Issue.2 , pp. 859-867
    • Kayikci, M.1    Milanovic, J.V.2
  • 2
    • 79955541414 scopus 로고    scopus 로고
    • Enhancing frequency response control by DFlGs in the high wind penetrated power systems
    • May 2011
    • Le-Ren Chang-Chien; Wei-Ting Lin; Yao-Ching Yin, "Enhancing Frequency Response Control by DFlGs in the High Wind Penetrated Power Systems, " iEEE Transactions on Power System, vo1. 26, no. 2, pp. 710, 718, May 2011
    • IEEE Transactions on Power System , vol.26 , Issue.2 , pp. 710-718
    • Chang-Chien, L.1    Lin, W.2    Yin, Y.3
  • 4
    • 84898063012 scopus 로고    scopus 로고
    • Participation of wind power plants in system frequency control: Review of grid code requirements and control methods
    • Mar.
    • F. Diaz-Gonzalez, M. Hau, A. Sumper, O. Gomis-Bellmunt, "Participation of wind power plants in system frequency control: Review of grid code requirements and control methods, " Renewable and Sustainable Energy Reviews, voI. 34, pp. 954, 959, Mar. 2014
    • (2014) Renewable and Sustainable Energy Reviews , vol.34 , pp. 954-959
    • Diaz-Gonzalez, F.1    Hau, M.2    Sumper, A.3    Gomis-Bellmunt, O.4
  • 5
    • 78751703126 scopus 로고    scopus 로고
    • Review of contribution to frequency control through variable speed wind turbine
    • Dec.
    • X. Yingcheng, T. Nengling, "Review of contribution to frequency control through variable speed wind turbine, "Renewable Energy Journal, vo1. 36, pp. 1671, 1677, Dec. 2010
    • (2010) Renewable Energy Journal , vol.36 , pp. 1671-1677
    • Yingcheng, X.1    Nengling, T.2
  • 7
    • 0036575603 scopus 로고    scopus 로고
    • Doubly fed induction generator systems for wind turbines
    • May
    • S. Muller, M. Deicke, and RW. De Doncker, " Doubly fed induction generator systems for wind turbines". iEEE industry Applications Magazine vol. 8, issue 3 p. : 26-33, May 2002
    • (2002) IEEE Industry Applications Magazine , vol.8 , Issue.3 , pp. 26-33
    • Muller, S.1    Deicke, M.2    De Doncker, R.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.