메뉴 건너뛰기




Volumn 35, Issue 4, 2016, Pages 423-432

Proximal thoracic aorta dimensions after continuous-flow left ventricular assist device implantation: Longitudinal changes and relation to aortic valve insufficiency

Author keywords

aorta; aortic valve insufficiency; heart failure; left ventricular assist device; mechanical circulatory support

Indexed keywords

ADULT; AGE; AGED; AORTA ROOT; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; AORTIC VALVE REPAIR; ARTICLE; ASCENDING AORTA; BLOOD PRESSURE MEASUREMENT; CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE; ECHOCARDIOGRAPHY; FEMALE; FOLLOW UP; HEART CYCLE; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; MALE; MEDICAL RECORD REVIEW; MIDDLE AGED; PEAK SYSTOLIC VELOCITY; PRIORITY JOURNAL; PROXIMAL THORACIC AORTA DIMENSION; THORACIC AORTA; TRANSTHORACIC ECHOCARDIOGRAPHY; AORTIC VALVE INSUFFICIENCY; COMPLICATION; DIAGNOSTIC IMAGING; HEART ASSIST DEVICE; HEART FAILURE; HEART LEFT VENTRICLE FUNCTION; PATHOPHYSIOLOGY; PHYSIOLOGY; PROCEDURES; RETROSPECTIVE STUDY; TIME FACTOR;

EID: 84949575734     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2015.10.029     Document Type: Article
Times cited : (27)

References (27)
  • 1
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • M.S. Slaughter, J.G. Rogers, C.A. Milano, and et al. Advanced heart failure treated with continuous-flow left ventricular assist device N Engl J Med 361 2009 2241 2251
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 2
    • 34548311569 scopus 로고    scopus 로고
    • Use of a continuous-flow device in patients awaiting heart transplantation
    • L.W. Miller, F.D. Pagani, S.D. Russell, and et al. Use of a continuous-flow device in patients awaiting heart transplantation N Engl J Med 357 2007 885 896
    • (2007) N Engl J Med , vol.357 , pp. 885-896
    • Miller, L.W.1    Pagani, F.D.2    Russell, S.D.3
  • 3
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • F.D. Pagani, L.W. Miller, S.D. Russell, and et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device J Am Coll Cardiol 54 2009 312 321
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 4
    • 77957234680 scopus 로고    scopus 로고
    • Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices
    • S.W. Pak, N. Uriel, H. Takayama, and et al. Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices J Heart Lung Transplant 29 2010 1172 1176
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1172-1176
    • Pak, S.W.1    Uriel, N.2    Takayama, H.3
  • 5
    • 78650096247 scopus 로고    scopus 로고
    • The development of aortic insufficiency in left ventricular assist device-supported patients
    • J. Cowger, F.D. Pagani, J.W. Haft, and et al. The development of aortic insufficiency in left ventricular assist device-supported patients Circ Heart Fail 3 2010 668 674
    • (2010) Circ Heart Fail , vol.3 , pp. 668-674
    • Cowger, J.1    Pagani, F.D.2    Haft, J.W.3
  • 6
    • 84900004511 scopus 로고    scopus 로고
    • Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients
    • U.P. Jorde, N. Uriel, N. Nahumi, and et al. Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients Circ Heart Fail 7 2014 310 319
    • (2014) Circ Heart Fail , vol.7 , pp. 310-319
    • Jorde, U.P.1    Uriel, N.2    Nahumi, N.3
  • 7
    • 82955189716 scopus 로고    scopus 로고
    • Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome
    • Y. Topilsky, T. Hasin, J.K. Oh, and et al. Echocardiographic variables after left ventricular assist device implantation associated with adverse outcome Circ Cardiovasc Imaging 4 2011 648 661
    • (2011) Circ Cardiovasc Imaging , vol.4 , pp. 648-661
    • Topilsky, Y.1    Hasin, T.2    Oh, J.K.3
  • 8
    • 84925515752 scopus 로고    scopus 로고
    • Recommendations for cardiac chamber quantification by echocardiography in adults: An update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging
    • R.M. Lang, L.P. Badano, V. Mor-Avi, and et al. Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging J Am Soc Echocardiogr 28 2015 1 39
    • (2015) J Am Soc Echocardiogr , vol.28 , pp. 1-39
    • Lang, R.M.1    Badano, L.P.2    Mor-Avi, V.3
  • 9
    • 0022588019 scopus 로고
    • Echocardiographic assessment of left ventricular hypertrophy: Comparison to necropsy findings
    • R.B. Devereux, D.R. Alonso, E.M. Lutas, and et al. Echocardiographic assessment of left ventricular hypertrophy: comparison to necropsy findings Am J Cardiol 57 1986 450 458
    • (1986) Am J Cardiol , vol.57 , pp. 450-458
    • Devereux, R.B.1    Alonso, D.R.2    Lutas, E.M.3
  • 10
    • 0142008980 scopus 로고    scopus 로고
    • Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography
    • W.A. Zoghbi, M. Enriquez-Sarano, E. Foster, and et al. Recommendations for evaluation of the severity of native valvular regurgitation with two-dimensional and Doppler echocardiography J Am Soc Echocardiogr 16 2003 777 802
    • (2003) J Am Soc Echocardiogr , vol.16 , pp. 777-802
    • Zoghbi, W.A.1    Enriquez-Sarano, M.2    Foster, E.3
  • 11
    • 77953661132 scopus 로고    scopus 로고
    • Guidelines for the echocardiographic assessment of the right heart in adults: A report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography
    • L.G. Rudski, W.W. Lai, J. Afilalo, and et al. Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography J Am Soc Echocardiogr 23 2010 685 713
    • (2010) J Am Soc Echocardiogr , vol.23 , pp. 685-713
    • Rudski, L.G.1    Lai, W.W.2    Afilalo, J.3
  • 12
    • 0030281648 scopus 로고    scopus 로고
    • Doppler echocardiographic index for assessment of global right ventricular function
    • C. Tei, K.S. Dujardin, D.O. Hodge, and et al. Doppler echocardiographic index for assessment of global right ventricular function J Am Soc Echocardiogr 9 1996 838 847
    • (1996) J Am Soc Echocardiogr , vol.9 , pp. 838-847
    • Tei, C.1    Dujardin, K.S.2    Hodge, D.O.3
  • 13
    • 84921443188 scopus 로고    scopus 로고
    • Multimodality imaging of diseases of the thoracic aorta in adults: From the American Society of Echocardiography and the European Association of Cardiovascular Imaging: Endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiovascular Magnetic Resonance
    • S.A. Goldstein, A. Evangelista, S. Abbara, and et al. Multimodality imaging of diseases of the thoracic aorta in adults: from the American Society of Echocardiography and the European Association of Cardiovascular Imaging: endorsed by the Society of Cardiovascular Computed Tomography and Society for Cardiovascular Magnetic Resonance J Am Soc Echocardiogr 28 2015 119 182
    • (2015) J Am Soc Echocardiogr , vol.28 , pp. 119-182
    • Goldstein, S.A.1    Evangelista, A.2    Abbara, S.3
  • 14
    • 77949654949 scopus 로고    scopus 로고
    • Standardizing the method of measuring by echocardiogram the diameter of the ascending aorta in patients with a bicuspid aortic valve
    • A.J. Albano, E. Mitchell, and L.A. Pape Standardizing the method of measuring by echocardiogram the diameter of the ascending aorta in patients with a bicuspid aortic valve Am J Cardiol 105 2010 1000 1004
    • (2010) Am J Cardiol , vol.105 , pp. 1000-1004
    • Albano, A.J.1    Mitchell, E.2    Pape, L.A.3
  • 15
    • 84866733874 scopus 로고    scopus 로고
    • Normal limits in relation to age, body size and gender of two-dimensional echocardiographic aortic root dimensions in persons >/=15 years of age
    • R.B. Devereux, G. de Simone, D.K. Arnett, and et al. Normal limits in relation to age, body size and gender of two-dimensional echocardiographic aortic root dimensions in persons >/=15 years of age Am J Cardiol 110 2012 1189 1194
    • (2012) Am J Cardiol , vol.110 , pp. 1189-1194
    • Devereux, R.B.1    De Simone, G.2    Arnett, D.K.3
  • 16
    • 79551548150 scopus 로고    scopus 로고
    • Echocardiographic findings in stable outpatients with properly functioning HeartMate II left ventricular assist devices
    • Y. Topilsky, J.K. Oh, F.W. Atchison, and et al. Echocardiographic findings in stable outpatients with properly functioning HeartMate II left ventricular assist devices J Am Soc Echocardiogr 24 2011 157 169
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 157-169
    • Topilsky, Y.1    Oh, J.K.2    Atchison, F.W.3
  • 17
    • 77950185458 scopus 로고    scopus 로고
    • 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease. A report of the American College of Cardiology Foundation
    • American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine
    • L.F. Hiratzka, G.L. Bakris, J.A. Beckman, and et al. 2010 ACCF/AHA/AATS/ACR/ASA/SCA/SCAI/SIR/STS/SVM guidelines for the diagnosis and management of patients with thoracic aortic disease. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines, American Association for Thoracic Surgery, American College of Radiology, American Stroke Association, Society of Cardiovascular Anesthesiologists, Society for Cardiovascular Angiography and Interventions, Society of Interventional Radiology, Society of Thoracic Surgeons, and Society for Vascular Medicine J Am Coll Cardiol 55 2010 e27-129
    • (2010) J Am Coll Cardiol , vol.55 , pp. e27-129
    • Hiratzka, L.F.1    Bakris, G.L.2    Beckman, J.A.3
  • 18
    • 84055172780 scopus 로고    scopus 로고
    • Changes in renal function after implantation of continuous-flow left ventricular assist devices
    • T. Hasin, Y. Topilsky, J.A. Schirger, and et al. Changes in renal function after implantation of continuous-flow left ventricular assist devices J Am Coll Cardiol 59 2012 26 36
    • (2012) J Am Coll Cardiol , vol.59 , pp. 26-36
    • Hasin, T.1    Topilsky, Y.2    Schirger, J.A.3
  • 19
    • 73449133718 scopus 로고    scopus 로고
    • Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device
    • S.D. Russell, J.G. Rogers, C.A. Milano, and et al. Renal and hepatic function improve in advanced heart failure patients during continuous-flow support with the HeartMate II left ventricular assist device Circulation 120 2009 2352 2357
    • (2009) Circulation , vol.120 , pp. 2352-2357
    • Russell, S.D.1    Rogers, J.G.2    Milano, C.A.3
  • 20
    • 84878172530 scopus 로고    scopus 로고
    • Use of centrifugal left ventricular assist device as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension
    • R.S. Kutty, J. Parameshwar, C. Lewis, and et al. Use of centrifugal left ventricular assist device as a bridge to candidacy in severe heart failure with secondary pulmonary hypertension Eur J Cardiothorac Surg 43 2013 1237 1242
    • (2013) Eur J Cardiothorac Surg , vol.43 , pp. 1237-1242
    • Kutty, R.S.1    Parameshwar, J.2    Lewis, C.3
  • 21
    • 0034784419 scopus 로고    scopus 로고
    • Novel technique to repair type A acute aortic dissection in patients with a left ventricular assist device
    • Y. Naka, N.M. Edwards, and M.C. Oz Novel technique to repair type A acute aortic dissection in patients with a left ventricular assist device Ann Thorac Surg 72 2001 1403 1404
    • (2001) Ann Thorac Surg , vol.72 , pp. 1403-1404
    • Naka, Y.1    Edwards, N.M.2    Oz, M.C.3
  • 22
    • 0035376466 scopus 로고    scopus 로고
    • Late aortic dissection in a patient with a left ventricular assist device
    • M. Dworschak, K. Wiesinger, N. Lorenzl, and et al. Late aortic dissection in a patient with a left ventricular assist device Jpn J Thorac Cardiovasc Surg 49 2001 395 397
    • (2001) Jpn J Thorac Cardiovasc Surg , vol.49 , pp. 395-397
    • Dworschak, M.1    Wiesinger, K.2    Lorenzl, N.3
  • 23
    • 0042623494 scopus 로고    scopus 로고
    • Resection of the ascending aorta and aortic valve patch closure for type A aortic dissection after Novacor LVAD insertion
    • V. Lacroix, Y. dUdekem, L. Jacquet, and et al. Resection of the ascending aorta and aortic valve patch closure for type A aortic dissection after Novacor LVAD insertion Eur J Cardiothorac Surg 24 2003 309 311
    • (2003) Eur J Cardiothorac Surg , vol.24 , pp. 309-311
    • Lacroix, V.1    Dudekem, Y.2    Jacquet, L.3
  • 24
    • 84864544205 scopus 로고    scopus 로고
    • TEVAR for ruptured mycotic aneurysm in a patient with a left ventricular assist device
    • E. Civilini, L. Bertoglio, E. Rinaldi, and et al. TEVAR for ruptured mycotic aneurysm in a patient with a left ventricular assist device J Endovasc Ther 19 2012 370 372
    • (2012) J Endovasc Ther , vol.19 , pp. 370-372
    • Civilini, E.1    Bertoglio, L.2    Rinaldi, E.3
  • 25
    • 33846397407 scopus 로고    scopus 로고
    • Circulatory support with attenuated pulse pressure alters human aortic wall morphology
    • S. Westaby, G.B. Bertoni, C. Clelland, and et al. Circulatory support with attenuated pulse pressure alters human aortic wall morphology J Thorac Cardiovasc Surg 133 2007 575 576
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 575-576
    • Westaby, S.1    Bertoni, G.B.2    Clelland, C.3
  • 26
    • 57049163522 scopus 로고    scopus 로고
    • Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device
    • J.O. Mudd, J.D. Cuda, M. Halushka, and et al. Fusion of aortic valve commissures in patients supported by a continuous axial flow left ventricular assist device J Heart Lung Transplant 27 2008 1269 1274
    • (2008) J Heart Lung Transplant , vol.27 , pp. 1269-1274
    • Mudd, J.O.1    Cuda, J.D.2    Halushka, M.3
  • 27
    • 84896546602 scopus 로고    scopus 로고
    • Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta
    • C. Karmonik, S. Partovi, M. Loebe, and et al. Computational fluid dynamics in patients with continuous-flow left ventricular assist device support show hemodynamic alterations in the ascending aorta J Thorac Cardiovasc Surg 147 2014 1326 1333
    • (2014) J Thorac Cardiovasc Surg , vol.147 , pp. 1326-1333
    • Karmonik, C.1    Partovi, S.2    Loebe, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.