메뉴 건너뛰기




Volumn 1496, Issue , 1998, Pages 421-430

Gauging clinical practice: Surgical navigation for total hip replacement

Author keywords

[No Author keywords available]

Indexed keywords

ALIGNMENT; ARTHROPLASTY; CLINICAL RESEARCH; HIP PROSTHESES; MEDICAL COMPUTING; MEDICAL IMAGING;

EID: 84947743611     PISSN: 03029743     EISSN: 16113349     Source Type: Book Series    
DOI: 10.1007/bfb0056227     Document Type: Conference Paper
Times cited : (10)

References (12)
  • 2
    • 0027048727 scopus 로고
    • Operative correction of an unstable total hip arthroplasty
    • Daly PJ, Morrey BF: Operative correction of an unstable total hip arthroplasty. J Bone Joint Surg 74A: 1334-1343, 1992.
    • (1992) J Bone Joint Surg , vol.74A , pp. 1334-1343
    • Daly, P.J.1    Morrey, B.F.2
  • 3
    • 0030970349 scopus 로고    scopus 로고
    • The prognosis and treatment of dislocated total hip arthroplasties with a 22 mm head
    • Hedlundh U, Sanzen L, Fredin H: The prognosis and treatment of dislocated total hip arthroplasties with a 22 mm head. J Bone Joint Surg 79B: 374-378, 1997.
    • (1997) J Bone Joint Surg , vol.79B , pp. 374-378
    • Hedlundh, U.1    Sanzen, L.2    Fredin, H.3
  • 5
    • 0017859205 scopus 로고
    • Dislocations after total hip replacement arthroplasties
    • Lewinnek GE, Lewis JL, Tarr R, et al.: Dislocations after total hip replacement arthroplasties. J Bone Joint Surg 60A: 217-220, 1978.
    • (1978) J Bone Joint Surg , vol.60A , pp. 217-220
    • Lewinnek, G.E.1    Lewis, J.L.2    Tarr, R.3
  • 6
    • 0025679123 scopus 로고
    • Dislocation after total hip arthroplasty: Causes and prevention
    • McCollum DE, Gray WJ: Dislocation after total hip arthroplasty: Causes and prevention. Clin Orthop 261: 159-170, 1990.
    • (1990) Clin Orthop , vol.261 , pp. 159-170
    • McCollum, D.E.1    Gray, W.J.2
  • 7
    • 0026525201 scopus 로고
    • Stability of cemented sockets after 3-14 years
    • Ohlin A, Balkfors B: Stability of cemented sockets after 3-14 years. J Arthro-plasty 7: 87-92, 1992.
    • (1992) J Arthro-Plasty , vol.7 , pp. 87-92
    • Ohlin, A.1    Balkfors, B.2
  • 8
    • 0031016456 scopus 로고    scopus 로고
    • Joint motion and surface contact area related to component position in total hip arthroplasty
    • Robinson RP, Simonian PT, Gradisar IM, Ching RP: Joint motion and surface contact area related to component position in total hip arthroplasty. J Bone Joint Surg 79B: 140-46, 1997.
    • (1997) J Bone Joint Surg , vol.79B , pp. 140-146
    • Robinson, R.P.1    Simonian, P.T.2    Gradisar, I.M.3    Ching, R.P.4
  • 9
    • 0029421462 scopus 로고
    • Techniques for fast and accurate intrasurgical registration
    • Simon D, Hebert M, Kanade T: Techniques for fast and accurate intrasurgical registration. J Image Guid Surg 1: 17-29, 1995.
    • (1995) J Image Guid Surg , vol.1 , pp. 17-29
    • Simon, D.1    Hebert, M.2    Kanade, T.3
  • 11
    • 84956664679 scopus 로고    scopus 로고
    • Development and validation of a navigational guidance system for acetabular implant placement
    • Grenoble, France, Springer
    • Simon DA, Jaramaz B, Blackwell M, et al.: Development and validation of a navigational guidance system for acetabular implant placement. First Joint Con-ference of CVRMed and MRCAS. Grenoble, France, Springer 583-592, 1997.
    • (1997) First Joint Con-Ference of Cvrmed and MRCAS , pp. 583-592
    • Simon, D.A.1    Jaramaz, B.2    Blackwell, M.3
  • 12
    • 0030666239 scopus 로고    scopus 로고
    • Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups
    • Yamaguchi M, Bauer T, Hashimoto Y: Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups. J Bone Joint Surg 79A: 1539-1544, 1997.
    • (1997) J Bone Joint Surg , vol.79A , pp. 1539-1544
    • Yamaguchi, M.1    Bauer, T.2    Hashimoto, Y.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.