메뉴 건너뛰기




Volumn 10, Issue 12, 2015, Pages 2035-2051

Multicenter study on the use of patient-specific CAD/CAM reconstruction plates for mandibular reconstruction

Author keywords

CAD CAM; Computer assisted surgery; Mandibular reconstruction; Patient specific implants; Patient specific mandible reconstruction plates; Surgical guides

Indexed keywords

ADULT; AGED; AMELOBLASTOMA; ANATOMICAL CONCEPTS; ARTICLE; BONE GRAFT; BONE NECROSIS; BONE PLATE; BONE PLATING SYSTEM; BONE REMODELING; CERVICAL SPINE FRACTURE; CLINICAL ARTICLE; COMPUTER AIDED DESIGN; COMPUTER AIDED MANUFACTURING; COMPUTER ASSISTED SURGERY; DECORTICATION; DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE; FIBULA GRAFT; GRAFT NECROSIS; HUMAN; JAW OSTEONECROSIS; MANDIBLE FRACTURE; MANDIBLE RECONSTRUCTION; MANDIBLE RESECTION; MIDDLE AGED; MULTICENTER STUDY; OPEN REDUCTION; OSTEOSYNTHESIS; PATHOLOGIC FRACTURE; PATIENT SPECIFIC MANDIBLE RECONSTRUCTION PLATE; PLATE FIXATION; POSTOPERATIVE COMPLICATION; PREOPERATIVE EVALUATION; PRIORITY JOURNAL; SQUAMOUS CELL CARCINOMA; SURGICAL INFECTION; TEMPOROMANDIBULAR JOINT; TIME; CLINICAL TRIAL; DEVICES; FEMALE; JAW DISEASES; MALE; PROCEDURES; PROSTHESIS DESIGN; SURGICAL FLAPS; VERY ELDERLY;

EID: 84947021280     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-015-1193-2     Document Type: Article
Times cited : (153)

References (23)
  • 1
    • 33745404132 scopus 로고    scopus 로고
    • A new method for computer-aided operation planning for extensive mandibular reconstruction
    • COI: 1:CAS:528:DC%2BD2sXlvFOisg%3D%3D, PID: 16772952
    • Hallermann W, Olsen S, Bardyn T, Taghizadeh F, Banic A, Iizuka T (2006) A new method for computer-aided operation planning for extensive mandibular reconstruction. Plast Reconstr Surg 117:2431–2437
    • (2006) Plast Reconstr Surg , vol.117 , pp. 2431-2437
    • Hallermann, W.1    Olsen, S.2    Bardyn, T.3    Taghizadeh, F.4    Banic, A.5    Iizuka, T.6
  • 2
    • 0034468104 scopus 로고    scopus 로고
    • Oromandibular reconstruction
    • COI: 1:STN:280:DC%2BD38%2FnsFGjug%3D%3D, PID: 11802362
    • Farwell D, Futuran N (2000) Oromandibular reconstruction. Facial Plast Surg 16:115–126
    • (2000) Facial Plast Surg , vol.16 , pp. 115-126
    • Farwell, D.1    Futuran, N.2
  • 3
    • 0034753866 scopus 로고    scopus 로고
    • Immediate reconstruction of continuity defects of the mandible after tumor surgery
    • COI: 1:STN:280:DC%2BD3MnjvFaqsw%3D%3D, PID: 11688038
    • Baker A, McMahon J, Parmar S (2001) Immediate reconstruction of continuity defects of the mandible after tumor surgery. J Oral Maxillofac Surg 59:1333–1339
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 1333-1339
    • Baker, A.1    McMahon, J.2    Parmar, S.3
  • 4
    • 0034758617 scopus 로고    scopus 로고
    • Delayed reconstruction of continuity defects of the mandible after tumor surgery
    • COI: 1:STN:280:DC%2BD3MnjvFaqsA%3D%3D, PID: 11688039
    • Schimmele S (2001) Delayed reconstruction of continuity defects of the mandible after tumor surgery. J Oral Maxillofac Surg 59:1340–1344
    • (2001) J Oral Maxillofac Surg , vol.59 , pp. 1340-1344
    • Schimmele, S.1
  • 5
    • 33750709349 scopus 로고    scopus 로고
    • Complete rehabilitation of the mandible following segmental resection
    • Schraag C, Yang-Ming C, Chi-Ying T, Fu-Chan W (2006) Complete rehabilitation of the mandible following segmental resection. J Surg Oncol 94:538–545
    • (2006) J Surg Oncol , vol.94 , pp. 538-545
    • Schraag, C.1    Yang-Ming, C.2    Chi-Ying, T.3    Fu-Chan, W.4
  • 6
    • 84938079710 scopus 로고    scopus 로고
    • Mandible reconstruction using patient-specific pre-bent reconstruction plates: comparison of standard and transfer key methods
    • PID: 24810111
    • Wilde F, Winter K, Kletsch K, Lorenz K, Schramm A (2015) Mandible reconstruction using patient-specific pre-bent reconstruction plates: comparison of standard and transfer key methods. Int J Comput Assist Radiol Surg 10:129–140
    • (2015) Int J Comput Assist Radiol Surg , vol.10 , pp. 129-140
    • Wilde, F.1    Winter, K.2    Kletsch, K.3    Lorenz, K.4    Schramm, A.5
  • 7
    • 34250797961 scopus 로고    scopus 로고
    • Feasibility of preoperative planning using anatomical facsimile models for mandibular reconstruction
    • Toro C, Robiony M, Costa M, Zerman N, Politi M (2007) Feasibility of preoperative planning using anatomical facsimile models for mandibular reconstruction. Head Face Med 15(3):5
    • (2007) Head Face Med , vol.15 , Issue.3 , pp. 5
    • Toro, C.1    Robiony, M.2    Costa, M.3    Zerman, N.4    Politi, M.5
  • 8
    • 84857640043 scopus 로고    scopus 로고
    • Mandible reconstruction with patient-specific pre-bent reconstruction plates: comparison of a transfer key method to the standard method - results of an in vitro study
    • PID: 21594568
    • Wilde F, Plail M, Riese C, Schramm A, Winter K (2011) Mandible reconstruction with patient-specific pre-bent reconstruction plates: comparison of a transfer key method to the standard method - results of an in vitro study. Int J Comput Assist Radiol Surg 7:57–63
    • (2011) Int J Comput Assist Radiol Surg , vol.7 , pp. 57-63
    • Wilde, F.1    Plail, M.2    Riese, C.3    Schramm, A.4    Winter, K.5
  • 9
    • 84922477216 scopus 로고    scopus 로고
    • Computer-assisted mandibular reconstruction using a patient-specific reconstruction plate fabricated with computer-aided design and manufacturing techniques
    • PID: 25045420
    • Wilde F, Cornelius C-P, Schramm A (2014) Computer-assisted mandibular reconstruction using a patient-specific reconstruction plate fabricated with computer-aided design and manufacturing techniques. Craniomaxillofac Trauma Reconstr 7:158–166
    • (2014) Craniomaxillofac Trauma Reconstr , vol.7 , pp. 158-166
    • Wilde, F.1    Cornelius, C.-P.2    Schramm, A.3
  • 10
    • 84947018137 scopus 로고    scopus 로고
    • ProPlan CMF Scanning Protocol (2014)
    • ProPlan CMF Scanning Protocol (2014) http://sites.synthes.com/intl/css/proplan/Pages/Downloads.aspx. Accessed 14 Oct 2014
  • 11
    • 84947019752 scopus 로고    scopus 로고
    • ProPlan CMF Request for Service—Mandible and midface reconstruction (2014)
    • ProPlan CMF Request for Service—Mandible and midface reconstruction (2014) http://sites.synthes.com/intl/css/proplan/Pages/Downloads.aspx Accessed Oct 2014
  • 12
    • 80053456798 scopus 로고    scopus 로고
    • Pre-operative planning for mandibular reconstruction—a full digital planning workflow resulting in a patient specific reconstruction
    • PID: 21968330
    • Essig H, Rana M, Kokemueller H, von See C, Ruecker M, Tavassol F, Gellrich NC (2011) Pre-operative planning for mandibular reconstruction—a full digital planning workflow resulting in a patient specific reconstruction. Head Neck Oncol 3:45
    • (2011) Head Neck Oncol , vol.3 , pp. 45
    • Essig, H.1    Rana, M.2    Kokemueller, H.3    von See, C.4    Ruecker, M.5    Tavassol, F.6    Gellrich, N.C.7
  • 13
    • 84900836708 scopus 로고    scopus 로고
    • Mandibular reconstruction with a prefabricated free vascularized fibula and implant-supported prosthesis based on fully three-dimensional virtual planning
    • PID: 24670276
    • Freudlsperger C, Bodem JP, Engel E, Hoffmann J (2014) Mandibular reconstruction with a prefabricated free vascularized fibula and implant-supported prosthesis based on fully three-dimensional virtual planning. J Craniofac Surg 25:980–982
    • (2014) J Craniofac Surg , vol.25 , pp. 980-982
    • Freudlsperger, C.1    Bodem, J.P.2    Engel, E.3    Hoffmann, J.4
  • 14
    • 0023944210 scopus 로고
    • Titanium-coated hollow screw and reconstruction plate system (THORP) in mandibular reconstruction
    • COI: 1:STN:280:DyaL1c3lslCqsg%3D%3D, PID: 3290261
    • Hellem S, Olofsson J (1988) Titanium-coated hollow screw and reconstruction plate system (THORP) in mandibular reconstruction. J Craniomaxillofac Surg 16:173–183
    • (1988) J Craniomaxillofac Surg , vol.16 , pp. 173-183
    • Hellem, S.1    Olofsson, J.2
  • 15
    • 0023808389 scopus 로고
    • Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases
    • COI: 1:STN:280:DyaL1M%2FhslKhtg%3D%3D, PID: 3174870
    • Vuillemin T, Raveh J, Sutter F (1988) Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases. Plast Reconstr Surg 82:804–814
    • (1988) Plast Reconstr Surg , vol.82 , pp. 804-814
    • Vuillemin, T.1    Raveh, J.2    Sutter, F.3
  • 16
    • 84947042055 scopus 로고    scopus 로고
    • Computerassistierte Unterkieferrekonstruktion unter Verwendung CAD/CAM gefertigter patientenspezifischer Unterkieferrekonstruktionsplatten. Eine Kadavermachbarkeitsstudie. Poster presentation, 62. Congress of the German Society of Oral-Maxillo-Facial-Surgery (DGMKG e.V.), 31 May–2 June 2012
    • Brsg, Germany
    • Wilde F, Cornelius C-P, Mascha F, Heufelder M, Schramm A (2012) Computerassistierte Unterkieferrekonstruktion unter Verwendung CAD/CAM gefertigter patientenspezifischer Unterkieferrekonstruktionsplatten. Eine Kadavermachbarkeitsstudie. Poster presentation, 62. Congress of the German Society of Oral-Maxillo-Facial-Surgery (DGMKG e.V.), 31 May–2 June 2012, Freiburg i. Brsg, Germany
    • (2012) Freiburg i
    • Wilde, F.1    Cornelius, C.-P.2    Mascha, F.3    Heufelder, M.4    Schramm, A.5
  • 17
    • 84975191983 scopus 로고    scopus 로고
    • Computer-assisted mandibular reconstruction with CAD/CAM-fabricated patient-specific reconstruction plates: a cadaver feasibility study
    • Wilde F, Cornelius C-P, Schramm A (2013) Computer-assisted mandibular reconstruction with CAD/CAM-fabricated patient-specific reconstruction plates: a cadaver feasibility study. Int J Comput Assist Radiol Surg 8(Suppl 1):87–88
    • (2013) Int J Comput Assist Radiol Surg , vol.8 , pp. 87-88
    • Wilde, F.1    Cornelius, C.-P.2    Schramm, A.3
  • 19
    • 0346251601 scopus 로고    scopus 로고
    • Condylar axis position, as determined by the occlusion and measured by the CPI instrument, and signs and symptoms of temporomandibular dysfunction
    • COI: 1:STN:280:DyaK1M3kt1Sruw%3D%3D, PID: 10227550
    • Crawford S (1999) Condylar axis position, as determined by the occlusion and measured by the CPI instrument, and signs and symptoms of temporomandibular dysfunction. Angle Orthod 69:103–115
    • (1999) Angle Orthod , vol.69 , pp. 103-115
    • Crawford, S.1
  • 20
    • 0021874917 scopus 로고
    • Maintenance of condylar position after sagittal split osteotomy of the mandible
    • COI: 1:STN:280:DyaL2M7osV2ltg%3D%3D
    • Leonard M (1985) Maintenance of condylar position after sagittal split osteotomy of the mandible. J Oral Maxillofax Surg 43:391–392
    • (1985) J Oral Maxillofax Surg , vol.43 , pp. 391-392
    • Leonard, M.1
  • 21
    • 0017009127 scopus 로고
    • Preventing rotation of the proximal fragment in the sagittal ramus split operation
    • COI: 1:STN:280:DyaE2s%2FgvVCrsQ%3D%3D, PID: 1067396
    • Leonard M (1976) Preventing rotation of the proximal fragment in the sagittal ramus split operation. J Oral Surg 34:942–942
    • (1976) J Oral Surg , vol.34 , pp. 942
    • Leonard, M.1
  • 22
    • 84887320001 scopus 로고    scopus 로고
    • Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison
    • COI: 1:CAS:528:DC%2BC3sXhs1OrtrrN, PID: 23924648
    • Seruya M, Fisher M, Rodriguez ED (2013) Computer-assisted versus conventional free fibula flap technique for craniofacial reconstruction: an outcomes comparison. Plast Reconstr Surg 132:1219–1228
    • (2013) Plast Reconstr Surg , vol.132 , pp. 1219-1228
    • Seruya, M.1    Fisher, M.2    Rodriguez, E.D.3
  • 23
    • 33846951796 scopus 로고    scopus 로고
    • Fracture of titanium plates used for mandibular reconstruction following ablative tumor surgery
    • PID: 16850467
    • Martola M, Lindqvist C, Hänninen H, Al-Sukhun J (2007) Fracture of titanium plates used for mandibular reconstruction following ablative tumor surgery. J Biomed Mater Res B Appl Biomater 80:345–352
    • (2007) J Biomed Mater Res B Appl Biomater , vol.80 , pp. 345-352
    • Martola, M.1    Lindqvist, C.2    Hänninen, H.3    Al-Sukhun, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.