메뉴 건너뛰기




Volumn 48, Issue 5, 2015, Pages e95-e101

Novel multi-dimensional modelling for surgical planning of acute aortic dissection type A based on computed tomography scan

Author keywords

3D modelling; Aortic dissection; Aortic tear; Quantification

Indexed keywords

ACUTE TYPE A AORTIC DISSECTION; ADULT; AGED; AORTA DISSECTION; AORTA WALL; ARTERY CATHETERIZATION; ARTICLE; ASCENDING AORTA; CLINICAL ARTICLE; COMPUTER ASSISTED TOMOGRAPHY; COMPUTER PROGRAM; FEMALE; FINITE ELEMENT ANALYSIS; FINITE ELEMENT MULTIDIMENSIONAL MODELLING; HUMAN; MALE; PRIORITY JOURNAL; RELIABILITY; RETROSPECTIVE STUDY; TREATMENT PLANNING; ANEURYSM, DISSECTING; AORTIC ANEURYSM; BIOLOGICAL MODEL; COMPUTER ASSISTED SURGERY; MIDDLE AGED; PROCEDURES; RADIOGRAPHY; THREE DIMENSIONAL IMAGING;

EID: 84946716797     PISSN: 10107940     EISSN: 1873734X     Source Type: Journal    
DOI: 10.1093/ejcts/ezv299     Document Type: Article
Times cited : (9)

References (25)
  • 1
    • 84922324261 scopus 로고    scopus 로고
    • Aortic valve repair: easy and reproducible?
    • Schäfers HJ. Aortic valve repair: easy and reproducible? J Thorac Cardiovasc Surg 2015;149:129-30.
    • (2015) J Thorac Cardiovasc Surg , vol.149 , pp. 129-130
    • Schäfers, H.J.1
  • 3
    • 78549256704 scopus 로고    scopus 로고
    • Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction
    • Clavel MA, Webb JG, Rodés-Cabau J, Masson JB, Dumont E, De Larochellière R et al. Comparison between transcatheter and surgical prosthetic valve implantation in patients with severe aortic stenosis and reduced left ventricular ejection fraction. Circulation 2010;122:1928-36.
    • (2010) Circulation , vol.122 , pp. 1928-1936
    • Clavel, M.A.1    Webb, J.G.2    Rodés-Cabau, J.3    Masson, J.B.4    Dumont, E.5    De Larochellière, R.6
  • 4
    • 84859160648 scopus 로고    scopus 로고
    • 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis
    • Willson AB, Webb JG, Labounty TM, Achenbach S, Moss R, Wheeler M et al. 3-dimensional aortic annular assessment by multidetector computed tomography predicts moderate or severe paravalvular regurgitation after transcatheter aortic valve replacement: a multicenter retrospective analysis. J Am Coll Cardiol 2012;59:1287-94.
    • (2012) J Am Coll Cardiol , vol.59 , pp. 1287-1294
    • Willson, A.B.1    Webb, J.G.2    Labounty, T.M.3    Achenbach, S.4    Moss, R.5    Wheeler, M.6
  • 6
    • 84874542770 scopus 로고    scopus 로고
    • Automated quantitative 3-dimensional modeling of the aortic valve and root by 3-dimensional transesophageal echocardiography in normals, aortic regurgitation, and aortic stenosis: comparison to computed tomography in normals and clinical implications
    • Calleja A, Thavendiranathan P, Ionasec RI, Houle H, Liu S, Voigt I et al. Automated quantitative 3-dimensional modeling of the aortic valve and root by 3-dimensional transesophageal echocardiography in normals, aortic regurgitation, and aortic stenosis: comparison to computed tomography in normals and clinical implications. Circ Cardiovasc Imaging 2013; 6:99-108.
    • (2013) Circ Cardiovasc Imaging , vol.6 , pp. 99-108
    • Calleja, A.1    Thavendiranathan, P.2    Ionasec, R.I.3    Houle, H.4    Liu, S.5    Voigt, I.6
  • 7
    • 84896869015 scopus 로고    scopus 로고
    • A perspective review on numerical simulations of hemodynamics in aortic dissection
    • Naim WN, Ganesan PB, Sun Z, Chee KH, Hashim SA, Lim E. A perspective review on numerical simulations of hemodynamics in aortic dissection. Sci World J 2014;2014:652520.
    • (2014) Sci World J , vol.2014
    • Naim, W.N.1    Ganesan, P.B.2    Sun, Z.3    Chee, K.H.4    Hashim, S.A.5    Lim, E.6
  • 8
    • 0032914189 scopus 로고    scopus 로고
    • Surgery for acute type A aortic dissection
    • discussion 2014-9
    • David TE, Armstrong S, Ivanov J, Barnard S. Surgery for acute type A aortic dissection. Ann Thorac Surg 1999;67:1999-2001; discussion 2014-9.
    • (1999) Ann Thorac Surg , vol.67 , pp. 1999-2001
    • David, T.E.1    Armstrong, S.2    Ivanov, J.3    Barnard, S.4
  • 10
    • 33846668865 scopus 로고    scopus 로고
    • Diagnosis and management of patients with aortic dissection
    • Ince H, Nienaber CA. Diagnosis and management of patients with aortic dissection. Heart 2007;93:266-70.
    • (2007) Heart , vol.93 , pp. 266-270
    • Ince, H.1    Nienaber, C.A.2
  • 12
    • 0015285440 scopus 로고
    • Use of the Hough transformation to detect lines and curves in pictures
    • Duda RO, Hart PE. Use of the Hough transformation to detect lines and curves in pictures. Commun ACM 1972;15:11-5.
    • (1972) Commun ACM , vol.15 , pp. 11-15
    • Duda, R.O.1    Hart, P.E.2
  • 14
    • 33646465323 scopus 로고    scopus 로고
    • Fast automated object detection by recursive casting of search rays
    • Lorenz C, von Berg J. Fast automated object detection by recursive casting of search rays. Computer Assisted Radiology and Surgery [CARS], Vol. 1281, 2005, 230-5, doi:10.1016/j.ics.2005.03.249.
    • (2005) Computer Assisted Radiology and Surgery [CARS] , vol.1281 , pp. 230-235
    • Lorenz, C.1    von Berg, J.2
  • 16
    • 33749421494 scopus 로고    scopus 로고
    • Automatic segmentation of the aortic dissection membrane from 3D CTA images. Medical Imaging and Augmented Reality
    • Kovács T, Cattin P, Alkadhi H, Wildermuth S, Székely G. Automatic segmentation of the aortic dissection membrane from 3D CTA images. Medical Imaging and Augmented Reality, Vol. 4091, Lecture Notes in Computer Science 2006, 317-24.
    • (2006) Lecture Notes in Computer Science , vol.4091 , pp. 317-324
    • Kovács, T.1    Cattin, P.2    Alkadhi, H.3    Wildermuth, S.4    Székely, G.5
  • 17
    • 84878330663 scopus 로고    scopus 로고
    • Aorta lumens centerlines extraction and possible entry tears location in the case of aortic dissections based on a 3D image topological analysis
    • Lohou C, Miguel B. Aorta lumens centerlines extraction and possible entry tears location in the case of aortic dissections based on a 3D image topological analysis. Comput Assist Radiol Surg. 2001;6:S312.
    • (2001) Comput Assist Radiol Surg , vol.6 , pp. S312
    • Lohou, C.1    Miguel, B.2
  • 18
    • 84878314880 scopus 로고    scopus 로고
    • 3D segmentation of the true and false lumens on CT aortic dissection images
    • Fetnaci N, Lubniewski PJ, Miguel B, Lohou C. 3D segmentation of the true and false lumens on CT aortic dissection images. Proc SPIE 2013;8650:1-15.
    • (2013) Proc SPIE , vol.8650 , pp. 1-15
    • Fetnaci, N.1    Lubniewski, P.J.2    Miguel, B.3    Lohou, C.4
  • 19
    • 0033623026 scopus 로고    scopus 로고
    • Suppression of high-density artefacts in X-ray CT images using temporal digital subtraction with application to cryotherapy
    • Baissalov R, Sandison GA, Donnelly BJ. Suppression of high-density artefacts in X-ray CT images using temporal digital subtraction with application to cryotherapy. Phys Med Biol 2000;45:53-9.
    • (2000) Phys Med Biol , vol.45 , pp. 53-59
    • Baissalov, R.1    Sandison, G.A.2    Donnelly, B.J.3
  • 21
    • 0041662025 scopus 로고    scopus 로고
    • Aortic dissection: new frontiers in diagnosis and management. Part II: therapeutic management and follow-up
    • Nienaber CA, Eagle KA. Aortic dissection: new frontiers in diagnosis and management. Part II: therapeutic management and follow-up. Circulation 2003;108:772-8.
    • (2003) Circulation , vol.108 , pp. 772-778
    • Nienaber, C.A.1    Eagle, K.A.2
  • 23
    • 84860238636 scopus 로고    scopus 로고
    • What is the best strategy for brain protection in patients undergoing aortic arch surgery? A single center experience of 636 patients
    • Misfeld M, Leontyev S, Borger MA, Gindensperger O, Lehmann S, Legare JF et al. What is the best strategy for brain protection in patients undergoing aortic arch surgery? A single center experience of 636 patients. Ann Thorac Surg 2012:93:1502-8.
    • (2012) Ann Thorac Surg , vol.93 , pp. 1502-1508
    • Misfeld, M.1    Leontyev, S.2    Borger, M.A.3    Gindensperger, O.4    Lehmann, S.5    Legare, J.F.6
  • 24
    • 33846392243 scopus 로고    scopus 로고
    • The safety of moderate hypothermic lower body circulatory arrest with selective cerebral perfusion: a propensity score analysis
    • Kamiya H, Hagl C, Kropivnitskaya I, Böthig D, Kallenbach K, Khaladj N et al. The safety of moderate hypothermic lower body circulatory arrest with selective cerebral perfusion: a propensity score analysis. J Thorac Cardiovasc Surg 2007;133:501-9.
    • (2007) J Thorac Cardiovasc Surg , vol.133 , pp. 501-509
    • Kamiya, H.1    Hagl, C.2    Kropivnitskaya, I.3    Böthig, D.4    Kallenbach, K.5    Khaladj, N.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.