메뉴 건너뛰기




Volumn 10, Issue 9, 2015, Pages

Tuberculosis laboratory diagnosis quality assurance among public health facilities in West Amhara Region, Ethiopia

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CONTROLLED STUDY; CROSS-SECTIONAL STUDY; DIAGNOSTIC ERROR; ETHIOPIA; FALSE NEGATIVE RESULT; FALSE POSITIVE RESULT; HEALTH CARE QUALITY; LABORATORY DIAGNOSIS; MICROSCOPE; PUBLIC HEALTH SERVICE; QUALITY CONTROL; SPUTUM CYTODIAGNOSIS; SPUTUM SMEAR; STRUCTURED QUESTIONNAIRE; TUBERCULOSIS; GOOD LABORATORY PRACTICE; HUMAN; ISOLATION AND PURIFICATION; LABORATORY; LABORATORY TEST; LOT QUALITY ASSURANCE SAMPLING; MICROBIOLOGICAL EXAMINATION; MICROBIOLOGY; MICROSCOPY; MYCOBACTERIUM TUBERCULOSIS; SPUTUM; STANDARDS;

EID: 84945547514     PISSN: None     EISSN: 19326203     Source Type: Journal    
DOI: 10.1371/journal.pone.0138488     Document Type: Article
Times cited : (13)

References (19)
  • 5
    • 84945537688 scopus 로고    scopus 로고
    • Quality assurance of sputum microscopy in DOTS program
    • Geneva, Switzerland: World Health Organization Press
    • World Health Organization. Quality assurance of sputum microscopy in DOTS program. Guidelines for Pacific Island Countries. Geneva, Switzerland: World Health Organization Press; 2003.
    • (2003) Guidelines for Pacific Island Countries
    • World Health Organization1
  • 8
    • 40749147258 scopus 로고    scopus 로고
    • Sputum smear microscopy: Evaluation of impact of training, microscope distribution, and use of external quality assessment guidelines for resource-poor settings
    • Rie A, Fitzgerald D, Kabuya G, Deun A, Tabala M, Jarret N, et al. Sputum Smear Microscopy: Evaluation of Impact of Training, Microscope Distribution, and Use of External Quality Assessment Guidelines for Resource-Poor Settings. J Clin Microbiol 2008; 46(3): 897-901.
    • (2008) J Clin Microbiol , vol.46 , Issue.3 , pp. 897-901
    • Rie, A.1    Fitzgerald, D.2    Kabuya, G.3    Deun, A.4    Tabala, M.5    Jarret, N.6
  • 9
    • 78649237109 scopus 로고    scopus 로고
    • Efforts of NTI as a national reference laboratory for implementation of External Quality Assessment for sputum microscopy in the ten allotted states during 2005-06
    • Ajaykumar T, Shilpa S, Shyni S, Balasangameshwara V, Kumar P. Efforts of NTI as a national reference laboratory for implementation of External Quality Assessment for sputum microscopy in the ten allotted states during 2005-06. NTI Bulletin [Bulletin]. 2006; 42:15-24.
    • (2006) NTI Bulletin [Bulletin]. , vol.42 , pp. 15-24
    • Ajaykumar, T.1    Shilpa, S.2    Shyni, S.3    Balasangameshwara, V.4    Kumar, P.5
  • 10
    • 84945559808 scopus 로고    scopus 로고
    • Panel testing of sputum smear microscopy of national tuberculosis reference laboratories in SAARC region: 2003-2010
    • Jha K, Thapa B, Salhotra V, Afridi N. Panel testing of sputum smear microscopy of national tuberculosis reference laboratories in SAARC region: 2003-2010. SAARC j tuber lung dis HIV/AIDS 2011; 8(1): 20-30.
    • (2011) SAARC J Tuber Lung Dis HIV/AIDS , vol.8 , Issue.1 , pp. 20-30
    • Jha, K.1    Thapa, B.2    Salhotra, V.3    Afridi, N.4
  • 11
    • 20844448536 scopus 로고    scopus 로고
    • Lot quality assurance sampling of sputum acid-fast bacillus smears for assessing sputum smear microscopy centers
    • Selvakumar N, Murthy B, Prabhakaran E, Sivagamasundari S, Vasanthan S, Perumal M, et al. Lot Quality Assurance Sampling of Sputum Acid-Fast Bacillus Smears for Assessing Sputum Smear Microscopy Centers. J Clin Microbiol 2005; 43(2): 913-5.
    • (2005) J Clin Microbiol , vol.43 , Issue.2 , pp. 913-915
    • Selvakumar, N.1    Murthy, B.2    Prabhakaran, E.3    Sivagamasundari, S.4    Vasanthan, S.5    Perumal, M.6
  • 12
    • 33748492328 scopus 로고    scopus 로고
    • Quality assessment of sputum smears microscopy for detection of Acid fast bacilli in peripheral health care facilities in Dar es Salaam, Tanzania
    • Basra D, Matee M, Mcnerney R. Quality assessment of sputum smears microscopy for detection of Acid fast bacilli in peripheral health care facilities in Dar Es Salaam, Tanzania. East Afr Med J 2006; 83(6): 306-10.
    • (2006) East Afr Med J , vol.83 , Issue.6 , pp. 306-310
    • Basra, D.1    Matee, M.2    Mcnerney, R.3
  • 13
    • 70949104698 scopus 로고    scopus 로고
    • Quality control of sputum microscopy at Sub-district level
    • Sarin R, Singla N, Mukerjee S, Sharma P. Quality control of sputum microscopy at Sub-district level. Ind J Tub 2002; 49:143.
    • (2002) Ind J Tub , vol.49 , pp. 143
    • Sarin, R.1    Singla, N.2    Mukerjee, S.3    Sharma, P.4
  • 14
    • 84945558783 scopus 로고    scopus 로고
    • The results of three years surveillance on sputum smear microscopy in 285 district and regional tuberculosis laboratories of Iran
    • Farnia P, Masjedi M, Mohammadi F, Nasehi M, Foroozesh M, Salek S, et al. The Results of Three Years Surveillance on Sputum Smear Microscopy in 285 District and Regional Tuberculosis Laboratories of Iran. Tanaffos 2003; 2(5): 29-36.
    • (2003) Tanaffos , vol.2 , Issue.5 , pp. 29-36
    • Farnia, P.1    Masjedi, M.2    Mohammadi, F.3    Nasehi, M.4    Foroozesh, M.5    Salek, S.6
  • 15
    • 0033053363 scopus 로고    scopus 로고
    • Quality control of smear microscopy for acid-fast bacilli: The case for blinded re-reading
    • Lan N, Wells C, Binkin N, Becerra J, Linh P, Cô N. Quality control of smear microscopy for acid-fast bacilli: the case for blinded re-reading. Int J Tuberc Lung Dis 1999; 3(1): 55-61.
    • (1999) Int J Tuberc Lung Dis , vol.3 , Issue.1 , pp. 55-61
    • Lan, N.1    Wells, C.2    Binkin, N.3    Becerra, J.4    Linh, P.5    Cô, N.6
  • 16
    • 34447278821 scopus 로고    scopus 로고
    • Optimizing sputum smear microscopy for the diagnosis of pulmonary tuberculosis
    • Steingart R, Ramsay A, Pai M. Optimizing sputum smear microscopy for the diagnosis of pulmonary tuberculosis. Expert Rev Anti Infect Ther 2007; 5: 327-31.
    • (2007) Expert Rev Anti Infect Ther , vol.5 , pp. 327-331
    • Steingart, R.1    Ramsay, A.2    Pai, M.3
  • 17
    • 67649522697 scopus 로고    scopus 로고
    • External quality assessment of sputum smears microscopy in Taiwan
    • Wu M, Chiang C, Jou R, Chang S, Luh K. External quality assessment of sputum smears microscopy in Taiwan. Int J Tuberc Lung Dis 2009; 13(5): 606-12.
    • (2009) Int J Tuberc Lung Dis , vol.13 , Issue.5 , pp. 606-612
    • Wu, M.1    Chiang, C.2    Jou, R.3    Chang, S.4    Luh, K.5
  • 18
    • 5644295623 scopus 로고    scopus 로고
    • Quality assessment of smear microscopy for acid-fast bacilli in the Argentine tuberculosis laboratory network, 1983-2001
    • Kusznierz G, Latini O, Sequeira M. Quality assessment of smear microscopy for acid-fast bacilli in the Argentine tuberculosis laboratory network, 1983-2001. Int J Tuberc Lung Dis 2004; 8(10): 1234-41.
    • (2004) Int J Tuberc Lung Dis , vol.8 , Issue.10 , pp. 1234-1241
    • Kusznierz, G.1    Latini, O.2    Sequeira, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.