메뉴 건너뛰기




Volumn 35, Issue 11, 2015, Pages 2392-2400

Impact of skin capsular distance on the performance of controlled attenuation parameter in patients with chronic liver disease

Author keywords

Controlled attenuation parameter; Liver stiffness; Non alcoholic fatty liver disease; Skin capsular distance; Transient elastography

Indexed keywords

ALANINE AMINOTRANSFERASE; ALBUMIN; ASPARTATE AMINOTRANSFERASE; HIGH DENSITY LIPOPROTEIN CHOLESTEROL; LOW DENSITY LIPOPROTEIN CHOLESTEROL; TRIACYLGLYCEROL;

EID: 84945435747     PISSN: 14783223     EISSN: 14783231     Source Type: Journal    
DOI: 10.1111/liv.12809     Document Type: Article
Times cited : (79)

References (27)
  • 1
    • 78049485434 scopus 로고    scopus 로고
    • Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: a multicenter prospective study (the FIBROSTIC study)
    • Degos F, Perez P, Roche B, et al. Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: a multicenter prospective study (the FIBROSTIC study). J Hepatol 2010; 53: 1013-21.
    • (2010) J Hepatol , vol.53 , pp. 1013-1021
    • Degos, F.1    Perez, P.2    Roche, B.3
  • 2
    • 78851470616 scopus 로고    scopus 로고
    • Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population
    • Wong GL, Wong VW, Chim AM, et al. Factors associated with unreliable liver stiffness measurement and its failure with transient elastography in the Chinese population. J Gastroenterol Hepatol 2011; 26: 300-5.
    • (2011) J Gastroenterol Hepatol , vol.26 , pp. 300-305
    • Wong, G.L.1    Wong, V.W.2    Chim, A.M.3
  • 3
    • 84155188892 scopus 로고    scopus 로고
    • Feasibility and diagnostic performance of the FibroScan XL probe for liver stiffness measurement in overweight and obese patients
    • Myers RP, Pomier-Layrargues G, Kirsch R, et al. Feasibility and diagnostic performance of the FibroScan XL probe for liver stiffness measurement in overweight and obese patients. Hepatology 2012; 55: 199-208.
    • (2012) Hepatology , vol.55 , pp. 199-208
    • Myers, R.P.1    Pomier-Layrargues, G.2    Kirsch, R.3
  • 4
    • 77956015752 scopus 로고    scopus 로고
    • Feasibility of liver transient elastography with FibroScan using a new probe for obese patients
    • de Ledinghen V, Vergniol J, Foucher J, et al. Feasibility of liver transient elastography with FibroScan using a new probe for obese patients. Liver Int 2010; 30: 1043-8.
    • (2010) Liver Int , vol.30 , pp. 1043-1048
    • de Ledinghen, V.1    Vergniol, J.2    Foucher, J.3
  • 5
    • 84861961483 scopus 로고    scopus 로고
    • Controlled Attenuation Parameter (CAP): a noninvasive method for the detection of hepatic steatosis based on transient elastography
    • Myers RP, Pollett A, Kirsch R, et al. Controlled Attenuation Parameter (CAP): a noninvasive method for the detection of hepatic steatosis based on transient elastography. Liver Int 2012; 32: 902-10.
    • (2012) Liver Int , vol.32 , pp. 902-910
    • Myers, R.P.1    Pollett, A.2    Kirsch, R.3
  • 6
    • 84898827951 scopus 로고    scopus 로고
    • Controlled attenuation parameter (CAP) for the diagnosis of steatosis: a prospective study of 5323 examinations
    • de Ledinghen V, Vergniol J, Capdepont M, et al. Controlled attenuation parameter (CAP) for the diagnosis of steatosis: a prospective study of 5323 examinations. J Hepatol 2014; 60: 1026-31.
    • (2014) J Hepatol , vol.60 , pp. 1026-1031
    • de Ledinghen, V.1    Vergniol, J.2    Capdepont, M.3
  • 7
    • 84858276083 scopus 로고    scopus 로고
    • Novel controlled attenuation parameter for noninvasive assessment of steatosis using Fibroscan((R)): validation in chronic hepatitis C
    • Sasso M, Tengher-Barna I, Ziol M, et al. Novel controlled attenuation parameter for noninvasive assessment of steatosis using Fibroscan((R)): validation in chronic hepatitis C. J Viral Hepat 2012; 19: 244-53.
    • (2012) J Viral Hepat , vol.19 , pp. 244-253
    • Sasso, M.1    Tengher-Barna, I.2    Ziol, M.3
  • 8
    • 84890119533 scopus 로고    scopus 로고
    • Controlled attenuation parameter (CAP) for detection of hepatic steatosis in patients with chronic liver diseases: a prospective study of a native Korean population
    • Chon YE, Jung KS, Kim SU, et al. Controlled attenuation parameter (CAP) for detection of hepatic steatosis in patients with chronic liver diseases: a prospective study of a native Korean population. Liver Int 2013; 34: 102-9.
    • (2013) Liver Int , vol.34 , pp. 102-109
    • Chon, Y.E.1    Jung, K.S.2    Kim, S.U.3
  • 10
    • 84862023903 scopus 로고    scopus 로고
    • The effects of fatty deposits on the accuracy of the Fibroscan(R) liver transient elastography ultrasound system
    • Cournane S, Browne JE, Fagan AJ. The effects of fatty deposits on the accuracy of the Fibroscan(R) liver transient elastography ultrasound system. Phys Med Biol 2012; 57: 3901-14.
    • (2012) Phys Med Biol , vol.57 , pp. 3901-3914
    • Cournane, S.1    Browne, J.E.2    Fagan, A.J.3
  • 11
    • 84870819164 scopus 로고    scopus 로고
    • Liver stiffness measurement using XL probe in patients with nonalcoholic fatty liver disease
    • Wong VW, Vergniol J, Wong GL, et al. Liver stiffness measurement using XL probe in patients with nonalcoholic fatty liver disease. Am J Gastroenterol 2012; 107: 1862-71.
    • (2012) Am J Gastroenterol , vol.107 , pp. 1862-1871
    • Wong, V.W.1    Vergniol, J.2    Wong, G.L.3
  • 12
    • 79251581867 scopus 로고    scopus 로고
    • Guidelines for the diagnosis and management of nonalcoholic fatty liver disease: update 2010: (published in Chinese on Chinese Journal of Hepatology 2010; 18:163-166)
    • Fan JG, Jia JD, Li YM, et al. Guidelines for the diagnosis and management of nonalcoholic fatty liver disease: update 2010: (published in Chinese on Chinese Journal of Hepatology 2010; 18:163-166). J Dig Dis 2011; 12: 38-44.
    • (2011) J Dig Dis , vol.12 , pp. 38-44
    • Fan, J.G.1    Jia, J.D.2    Li, Y.M.3
  • 13
    • 49849087685 scopus 로고    scopus 로고
    • Prevalence and risk factors of hepatic steatosis and its impact on liver injury in Chinese patients with chronic hepatitis B infection
    • Shi JP, Fan JG, Wu R, et al. Prevalence and risk factors of hepatic steatosis and its impact on liver injury in Chinese patients with chronic hepatitis B infection. J Gastroenterol Hepatol 2008; 23: 1419-25.
    • (2008) J Gastroenterol Hepatol , vol.23 , pp. 1419-1425
    • Shi, J.P.1    Fan, J.G.2    Wu, R.3
  • 14
    • 20044374023 scopus 로고    scopus 로고
    • Design and validation of a histological scoring system for nonalcoholic fatty liver disease
    • Kleiner DE, Brunt EM, Van Natta M, et al. Design and validation of a histological scoring system for nonalcoholic fatty liver disease. Hepatology 2005; 41: 1313-21.
    • (2005) Hepatology , vol.41 , pp. 1313-1321
    • Kleiner, D.E.1    Brunt, E.M.2    Van Natta, M.3
  • 15
    • 0029778988 scopus 로고    scopus 로고
    • An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group
    • Bedossa P, Poynard T. An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group. Hepatology 1996; 24: 289-93.
    • (1996) Hepatology , vol.24 , pp. 289-293
    • Bedossa, P.1    Poynard, T.2
  • 16
    • 84879458387 scopus 로고    scopus 로고
    • Controlled attenuation parameter for non-invasive assessment of hepatic steatosis: does aetiology affect performance
    • Kumar M, Rastogi A, Singh T, et al. Controlled attenuation parameter for non-invasive assessment of hepatic steatosis: does aetiology affect performance. J Gastroenterol Hepatol 2013; 28: 1194-201.
    • (2013) J Gastroenterol Hepatol , vol.28 , pp. 1194-1201
    • Kumar, M.1    Rastogi, A.2    Singh, T.3
  • 17
    • 75749117209 scopus 로고    scopus 로고
    • Transient elastography assessment of the liver stiffness dynamics during acute hepatitis B
    • Vigano M, Massironi S, Lampertico P, et al. Transient elastography assessment of the liver stiffness dynamics during acute hepatitis B. Eur J Gastroenterol Hepatol 2010; 22: 180-4.
    • (2010) Eur J Gastroenterol Hepatol , vol.22 , pp. 180-184
    • Vigano, M.1    Massironi, S.2    Lampertico, P.3
  • 18
    • 75349114937 scopus 로고    scopus 로고
    • Liver stiffness is directly influenced by central venous pressure
    • Millonig G, Friedrich S, Adolf S, et al. Liver stiffness is directly influenced by central venous pressure. J Hepatol 2010; 52: 206-10.
    • (2010) J Hepatol , vol.52 , pp. 206-210
    • Millonig, G.1    Friedrich, S.2    Adolf, S.3
  • 19
    • 56149103873 scopus 로고    scopus 로고
    • Extrahepatic cholestasis increases liver stiffness (FibroScan) irrespective of fibrosis
    • Millonig G, Reimann FM, Friedrich S, et al. Extrahepatic cholestasis increases liver stiffness (FibroScan) irrespective of fibrosis. Hepatology 2008; 48: 1718-23.
    • (2008) Hepatology , vol.48 , pp. 1718-1723
    • Millonig, G.1    Reimann, F.M.2    Friedrich, S.3
  • 20
    • 84898640575 scopus 로고    scopus 로고
    • Non-invasive assessment of hepatic steatosis in patients with NAFLD using controlled attenuation parameter and 1H-MR spectroscopy
    • Karlas T, Petroff D, Garnov N, et al. Non-invasive assessment of hepatic steatosis in patients with NAFLD using controlled attenuation parameter and 1H-MR spectroscopy. PLoS ONE 2014; 9: e91987.
    • (2014) PLoS ONE , vol.9 , pp. e91987
    • Karlas, T.1    Petroff, D.2    Garnov, N.3
  • 21
    • 84899653695 scopus 로고    scopus 로고
    • Controlled attenuation parameter for non-invasive assessment of hepatic steatosis in Chinese patients
    • Shen F, Zheng RD, Mi YQ, et al. Controlled attenuation parameter for non-invasive assessment of hepatic steatosis in Chinese patients. World J Gastroenterol 2014; 20: 4702-11.
    • (2014) World J Gastroenterol , vol.20 , pp. 4702-4711
    • Shen, F.1    Zheng, R.D.2    Mi, Y.Q.3
  • 22
    • 84902513255 scopus 로고    scopus 로고
    • Factors affecting the accuracy of controlled attenuation parameter (CAP) in assessing hepatic steatosis in patients with chronic liver disease
    • Jung KS, Kim BK, Kim SU, et al. Factors affecting the accuracy of controlled attenuation parameter (CAP) in assessing hepatic steatosis in patients with chronic liver disease. PLoS ONE 2014; 9: e98689.
    • (2014) PLoS ONE , vol.9 , pp. e98689
    • Jung, K.S.1    Kim, B.K.2    Kim, S.U.3
  • 23
    • 84904346796 scopus 로고    scopus 로고
    • Controlled attenuation parameter for the detection and quantification of hepatic steatosis in nonalcoholic fatty liver disease
    • Chan WK, Nik MNR, Mahadeva S. Controlled attenuation parameter for the detection and quantification of hepatic steatosis in nonalcoholic fatty liver disease. J Gastroenterol Hepatol 2014; 29: 1470-6.
    • (2014) J Gastroenterol Hepatol , vol.29 , pp. 1470-1476
    • Chan, W.K.1    Nik, M.N.R.2    Mahadeva, S.3
  • 24
    • 84858231170 scopus 로고    scopus 로고
    • Evaluation of transient elastography for fibrosis assessment compared with large biopsies in chronic hepatitis B and C
    • Verveer C, Zondervan PE, ten Kate FJ, et al. Evaluation of transient elastography for fibrosis assessment compared with large biopsies in chronic hepatitis B and C. Liver Int 2012; 32: 622-8.
    • (2012) Liver Int , vol.32 , pp. 622-628
    • Verveer, C.1    Zondervan, P.E.2    ten Kate, F.J.3
  • 25
    • 78649630014 scopus 로고    scopus 로고
    • Reliability of transient elastography for the detection of fibrosis in non-alcoholic fatty liver disease and chronic viral hepatitis
    • Gaia S, Carenzi S, Barilli AL, et al. Reliability of transient elastography for the detection of fibrosis in non-alcoholic fatty liver disease and chronic viral hepatitis. J Hepatol 2011; 54: 64-71.
    • (2011) J Hepatol , vol.54 , pp. 64-71
    • Gaia, S.1    Carenzi, S.2    Barilli, A.L.3
  • 26
    • 75449091784 scopus 로고    scopus 로고
    • Diagnosis of fibrosis and cirrhosis using liver stiffness measurement in nonalcoholic fatty liver disease
    • Wong VW, Vergniol J, Wong GL, et al. Diagnosis of fibrosis and cirrhosis using liver stiffness measurement in nonalcoholic fatty liver disease. Hepatology 2010; 51: 454-62.
    • (2010) Hepatology , vol.51 , pp. 454-462
    • Wong, V.W.1    Vergniol, J.2    Wong, G.L.3
  • 27
    • 71849092184 scopus 로고    scopus 로고
    • Validity of real time ultrasound in the diagnosis of hepatic steatosis: a prospective study
    • Dasarathy S, Dasarathy J, Khiyami A, et al. Validity of real time ultrasound in the diagnosis of hepatic steatosis: a prospective study. J Hepatol 2009; 51: 1061-7.
    • (2009) J Hepatol , vol.51 , pp. 1061-1067
    • Dasarathy, S.1    Dasarathy, J.2    Khiyami, A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.