메뉴 건너뛰기




Volumn 60, Issue 4, 2015, Pages 484-491

What is the potential role of transcutaneous carbon dioxide in guiding acute noninvasive ventilation?

Author keywords

Acute hypercapnic respiratory failure; NIV; Noninvasive ventilation; Transcutaneous carbon dioxide; Type 2 respiratory failure

Indexed keywords

ADULT; AGED; ARTERIAL GAS; ARTERIAL PH; ARTICLE; BLOOD GAS ANALYSIS; CLINICAL ARTICLE; COHORT ANALYSIS; HUMAN; HYPERCAPNIA; NONINVASIVE VENTILATION; OBSERVATIONAL STUDY; OUTCOME ASSESSMENT; PROSPECTIVE STUDY; RESPIRATORY FAILURE; SCORING SYSTEM; TRANSCUTANEOUS CARBON DIOXIDE MONITORING; VERY ELDERLY; BLOOD; MIDDLE AGED; PAIN MEASUREMENT; PH; PHYSIOLOGIC MONITORING; PILOT STUDY; PROCEDURES; REPRODUCIBILITY; RESPIRATORY INSUFFICIENCY; TRANSCUTANEOUS OXYGEN MONITORING;

EID: 84945295595     PISSN: 00201324     EISSN: 19433654     Source Type: Journal    
DOI: 10.4187/respcare.03335     Document Type: Article
Times cited : (24)

References (19)
  • 1
    • 0001532670 scopus 로고
    • Electrodes for blood pO2 and pCO2 determination
    • Severinghaus JW, Bradley AF. Electrodes for blood pO2 and pCO2 determination. J Appl Physiol 1958;13(3):515-520.
    • (1958) J Appl Physiol , vol.13 , Issue.3 , pp. 515-520
    • Severinghaus, J.W.1    Bradley, A.F.2
  • 2
    • 0014097543 scopus 로고
    • Clinical sequelae from arterial needle puncture, cannulation, and incision
    • Mortensen JD. Clinical sequelae from arterial needle puncture, cannulation, and incision. Circulation 1967;35(6):1118-1123.
    • (1967) Circulation , vol.35 , Issue.6 , pp. 1118-1123
    • Mortensen, J.D.1
  • 3
    • 84863422126 scopus 로고    scopus 로고
    • Nocturnal oximetry and transcutaneous carbon dioxide in home-ventilated neuromuscular patients
    • Nardi J, Prigent H, Adala A, Bohic M, Lebargy F, Quera-Salva MA, et al. Nocturnal oximetry and transcutaneous carbon dioxide in home-ventilated neuromuscular patients. Respir Care 2012;57(9): 1425-1430.
    • (2012) Respir Care , vol.57 , Issue.9 , pp. 1425-1430
    • Nardi, J.1    Prigent, H.2    Adala, A.3    Bohic, M.4    Lebargy, F.5    Quera-Salva, M.A.6
  • 4
    • 78649936011 scopus 로고    scopus 로고
    • Transcutaneous monitoring as a replacement for arterial PCO2 monitoring during nocturnal non-invasive ventilation
    • Storre JH, Magnet FS, Dreher M, Windisch W. Transcutaneous monitoring as a replacement for arterial PCO2 monitoring during nocturnal non-invasive ventilation. Respir Med 2011;105(1):143-150.
    • (2011) Respir Med , vol.105 , Issue.1 , pp. 143-150
    • Storre, J.H.1    Magnet, F.S.2    Dreher, M.3    Windisch, W.4
  • 5
    • 0035001036 scopus 로고    scopus 로고
    • Noninvasive monitoring of carbon dioxide during mechanical ventilation in older children: End-tidal versus transcutaneous techniques
    • Berkenbosch JW, Lam J, Burd RS, Tobias JD. Noninvasive monitoring of carbon dioxide during mechanical ventilation in older children: end-tidal versus transcutaneous techniques. Anesth Analg 2001; 92(6):1427-1431.
    • (2001) Anesth Analg , vol.92 , Issue.6 , pp. 1427-1431
    • Berkenbosch, J.W.1    Lam, J.2    Burd, R.S.3    Tobias, J.D.4
  • 6
    • 33645562584 scopus 로고    scopus 로고
    • Noninvasive monitoring of CO2 levels in patients using NIV for AECOPD
    • Cox M, Kemp R, Anwar S, Athey V, Aung T, Moloney ED. Noninvasive monitoring of CO2 levels in patients using NIV for AECOPD. Thorax 2006;61(4):363-364.
    • (2006) Thorax , vol.61 , Issue.4 , pp. 363-364
    • Cox, M.1    Kemp, R.2    Anwar, S.3    Athey, V.4    Aung, T.5    Moloney, E.D.6
  • 7
    • 79953823196 scopus 로고    scopus 로고
    • Accuracy of a transcutaneous carbon dioxide pressure monitoring device in emergency room patients with acute respiratory failure
    • Gancel PE, Roupie E, Guittet L, Laplume S, Terzi N. Accuracy of a transcutaneous carbon dioxide pressure monitoring device in emergency room patients with acute respiratory failure. Intensive Care Med 2011;37(2):348-351.
    • (2011) Intensive Care Med , vol.37 , Issue.2 , pp. 348-351
    • Gancel, P.E.1    Roupie, E.2    Guittet, L.3    Laplume, S.4    Terzi, N.5
  • 8
    • 0034945461 scopus 로고    scopus 로고
    • Is continuous transcutaneous monitoring of PCO2 (Tc PCO2) over 8 h reliable in adults?
    • Janssens JP, Perrin E, Bennani I, de Muralt B, Titelion V, Picaud C. Is continuous transcutaneous monitoring of PCO2 (Tc PCO2) over 8 h reliable in adults? Respir Med 2001;95(5):331-335.
    • (2001) Respir Med , vol.95 , Issue.5 , pp. 331-335
    • Janssens, J.P.1    Perrin, E.2    Bennani, I.3    De Muralt, B.4    Titelion, V.5    Picaud, C.6
  • 9
    • 78651411852 scopus 로고    scopus 로고
    • Agreement between arterial and transcutaneous PCO2 in patients undergoing non-invasive ventilation
    • Kelly AM, Klim S. Agreement between arterial and transcutaneous PCO2 in patients undergoing non-invasive ventilation. Respir Med 2011;105(2):226-229.
    • (2011) Respir Med , vol.105 , Issue.2 , pp. 226-229
    • Kelly, A.M.1    Klim, S.2
  • 10
    • 80052888564 scopus 로고    scopus 로고
    • Evaluation of a transcutaneous carbon dioxide monitor in patients with acute respiratory failure
    • Nicolini A, Ferrari MB. Evaluation of a transcutaneous carbon dioxide monitor in patients with acute respiratory failure. Ann Thorac Med 2011;6(4):217-220.
    • (2011) Ann Thorac Med , vol.6 , Issue.4 , pp. 217-220
    • Nicolini, A.1    Ferrari, M.B.2
  • 11
    • 37549047635 scopus 로고    scopus 로고
    • Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation
    • Storre JH, Steurer B, Kabitz HJ, Dreher M, Windisch W. Transcutaneous PCO2 monitoring during initiation of noninvasive ventilation. Chest 2007;132(6):1810-1816.
    • (2007) Chest , vol.132 , Issue.6 , pp. 1810-1816
    • Storre, J.H.1    Steurer, B.2    Kabitz, H.J.3    Dreher, M.4    Windisch, W.5
  • 12
    • 79952280649 scopus 로고    scopus 로고
    • Validation of a transcutaneous CO2 monitor in adult patients with chronic respiratory failure
    • Hazenberg A, Zijlstra JG, Kerstjens HA, Wijkstra PJ. Validation of a transcutaneous CO2 monitor in adult patients with chronic respiratory failure. Respiration 2011;81(3):242-246.
    • (2011) Respiration , vol.81 , Issue.3 , pp. 242-246
    • Hazenberg, A.1    Zijlstra, J.G.2    Kerstjens, H.A.3    Wijkstra, P.J.4
  • 13
    • 77952585277 scopus 로고    scopus 로고
    • Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements
    • Chakravarthy M, Narayan S, Govindarajan R, Jawali V, Rajeev S. Weaning mechanical ventilation after off-pump coronary artery bypass graft procedures directed by noninvasive gas measurements. J Cardiothorac Vasc Anesth 2010;24(3):451-455.
    • (2010) J Cardiothorac Vasc Anesth , vol.24 , Issue.3 , pp. 451-455
    • Chakravarthy, M.1    Narayan, S.2    Govindarajan, R.3    Jawali, V.4    Rajeev, S.5
  • 14
    • 84945257590 scopus 로고    scopus 로고
    • Adult non-invasive ventilation audit summary report
    • Davidson C. 2010 Adult non-invasive ventilation audit summary report. https://www.brit-thoracic.org.uk/document-library/audit-andquality-improvement/audit-reports/bts-adult-niv-audit-report-2010. Accessed October 22, 2014.
    • (2010)
    • Davidson, C.1
  • 15
    • 79957652902 scopus 로고    scopus 로고
    • Studies comparing Numerical Rating Scales, Verbal Rating Scales, and Visual Analogue Scales for assessment of pain intensity in adults: A systematic literature review
    • Hjermstad MJ, Fayers PM, Haugen DF, Caraceni A, Hanks GW, Loge JH, et al. Studies comparing Numerical Rating Scales, Verbal Rating Scales, and Visual Analogue Scales for assessment of pain intensity in adults: a systematic literature review. J Pain Symptom Manage 2001;41(6):1073-1093.
    • (2001) J Pain Symptom Manage , vol.41 , Issue.6 , pp. 1073-1093
    • Hjermstad, M.J.1    Fayers, P.M.2    Haugen, D.F.3    Caraceni, A.4    Hanks, G.W.5    Loge, J.H.6
  • 16
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland M, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 327(8476):307-310.
    • (1986) Lancet , vol.327 , Issue.8476 , pp. 307-310
    • Bland, M.1    Altman, D.G.2
  • 17
    • 0028817632 scopus 로고
    • Arterial versus capillary sampling for analysing blood gas pressures
    • Dar K, Williams T, Aitken R, Woods KL, Fletcher S. Arterial versus capillary sampling for analysing blood gas pressures. BMJ 1995; 310(6971):24-25.
    • (1995) BMJ , vol.310 , Issue.6971 , pp. 24-25
    • Dar, K.1    Williams, T.2    Aitken, R.3    Woods, K.L.4    Fletcher, S.5
  • 18
    • 33947622063 scopus 로고    scopus 로고
    • The accuracy of non-invasive carbon dioxide monitoring: A clinical evaluation of two transcutaneous systems
    • Bolliger D, Steiner LA, Kasper J, Aziz OA, Filipovic M, Seeberger MD. The accuracy of non-invasive carbon dioxide monitoring: a clinical evaluation of two transcutaneous systems. Anaesthesia 2007; 62(4):394-399.
    • (2007) Anaesthesia , vol.62 , Issue.4 , pp. 394-399
    • Bolliger, D.1    Steiner, L.A.2    Kasper, J.3    Aziz, O.A.4    Filipovic, M.5    Seeberger, M.D.6
  • 19
    • 34447644801 scopus 로고    scopus 로고
    • Blood gas measurements using the Bayer Rapid Point 405: Are we basing our decisions on accurate data?
    • Sarrazin F, Tessler MJ, Kardash K, McNamara E, Holcroft C. Blood gas measurements using the Bayer Rapid Point 405: are we basing our decisions on accurate data? J Clin Monit Comput 2007;21(4):253-256.
    • (2007) J Clin Monit Comput , vol.21 , Issue.4 , pp. 253-256
    • Sarrazin, F.1    Tessler, M.J.2    Kardash, K.3    McNamara, E.4    Holcroft, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.