Volumn 104, Issue 11, 2015, Pages 1084-1089

Automated control of inspired oxygen in ventilated preterm infants: Crossover physiological study

Author keywords

Closed loop; Hyperoxaemia; Hypoxaemia; Oxygen saturation; Premature infants

Indexed keywords

OXYGEN;

EID: 84945156611     PISSN: 08035253     EISSN: 16512227     Source Type: Journal    
DOI: 10.1111/apa.13137     Document Type: Article
Times cited : (52)

References (16)
  • 1
    • 77956281923 scopus 로고    scopus 로고
    • Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network. Neonatal outcomes of extremely preterm infants from the NICHD Neonatal Research Network
    • Stoll BJ, Hansen NI, Bell EF, Shankaran S, Laptook AR, Walsh MC, et al., Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network. Neonatal outcomes of extremely preterm infants from the NICHD Neonatal Research Network. Pediatrics 2010; 126: 443-56.
    • (2010) Pediatrics , vol.126 , pp. 443-456
    • Stoll, B.J.1    Hansen, N.I.2    Bell, E.F.3    Shankaran, S.4    Laptook, A.R.5    Walsh, M.C.6
  • 2
    • 77952784840 scopus 로고    scopus 로고
    • NICHD Neonatal Research Network. Target ranges of oxygen saturation in extremely preterm infants
    • SUPPORT Study Group of the Eunice Kennedy Shriver
    • SUPPORT Study Group of the Eunice Kennedy Shriver. NICHD Neonatal Research Network. Target ranges of oxygen saturation in extremely preterm infants. N Engl J Med 2010; 362: 1959-69.
    • (2010) N Engl J Med , vol.362 , pp. 1959-1969
  • 3
    • 79955516934 scopus 로고    scopus 로고
    • Increased 36-week survival with high oxygen saturation target in extremely preterm infants
    • U.K. BOOST II trial; Australian BOOST II trial; New Zealand BOOST II trial
    • Stenson B, Brocklehurst P, Tarnow-Mordi W,; U.K. BOOST II trial; Australian BOOST II trial; New Zealand BOOST II trial. Increased 36-week survival with high oxygen saturation target in extremely preterm infants. N Engl J Med 2011; 364: 1680-2.
    • (2011) N Engl J Med , vol.364 , pp. 1680-1682
    • Stenson, B.1    Brocklehurst, P.2    Tarnow-Mordi, W.3
  • 4
    • 33744526222 scopus 로고    scopus 로고
    • Pulse oximetry in very low birth weight infants: Can oxygen saturation be maintained in the desired range?
    • Laptook AR, Salhab W, Allen J, Saha S, Walsh M,. Pulse oximetry in very low birth weight infants: can oxygen saturation be maintained in the desired range? J Perinatol 2006; 26: 337-41.
    • (2006) J Perinatol , vol.26 , pp. 337-341
    • Laptook, A.R.1    Salhab, W.2    Allen, J.3    Saha, S.4    Walsh, M.5
  • 5
    • 33750096536 scopus 로고    scopus 로고
    • Achieved versus intended pulse oximeter saturation in infants born less than 28 weeks' gestation: The AVIOx study
    • Hagadorn JI, Furey AM, Nghiem TH, Schmid CH, Phelps DL, Pillers DA, et al., Achieved versus intended pulse oximeter saturation in infants born less than 28 weeks' gestation: the AVIOx study. Pediatrics 2006; 118: 1574-82.
    • (2006) Pediatrics , vol.118 , pp. 1574-1582
    • Hagadorn, J.I.1    Furey, A.M.2    Nghiem, T.H.3    Schmid, C.H.4    Phelps, D.L.5    Pillers, D.A.6
  • 6
    • 0035003847 scopus 로고    scopus 로고
    • Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia
    • Claure N, Gerhardt T, Everett R, Musante G, Herrera C, Bancalari E,. Closed-loop controlled inspired oxygen concentration for mechanically ventilated very low birth weight infants with frequent episodes of hypoxemia. Pediatrics 2001; 107: 1120-4.
    • (2001) Pediatrics , vol.107 , pp. 1120-1124
    • Claure, N.1    Gerhardt, T.2    Everett, R.3    Musante, G.4    Herrera, C.5    Bancalari, E.6
  • 7
    • 71749093050 scopus 로고    scopus 로고
    • Automated adjustment of inspired oxygen in preterm infants with frequent fluctuations in oxygenation: A pilot clinical trial
    • Claure N, D'Ugard C, Bancalari E,. Automated adjustment of inspired oxygen in preterm infants with frequent fluctuations in oxygenation: a pilot clinical trial. J Pediatr 2009; 155: 640-5.
    • (2009) J Pediatr , vol.155 , pp. 640-645
    • Claure, N.1    D'Ugard, C.2    Bancalari, E.3
  • 8
    • 78650773975 scopus 로고    scopus 로고
    • Multicenter crossover study of automated adjustment of inspired oxygen in mechanically ventilated preterm infants
    • Claure N, Bancalari E, D'Ugard C, Nelin L, Stein M, Ramanathan R, et al., Multicenter crossover study of automated adjustment of inspired oxygen in mechanically ventilated preterm infants. Pediatrics 2011; 127: e76-83.
    • (2011) Pediatrics , vol.127 , pp. e76-e83
    • Claure, N.1    Bancalari, E.2    D'Ugard, C.3    Nelin, L.4    Stein, M.5    Ramanathan, R.6
  • 10
    • 84877954367 scopus 로고    scopus 로고
    • Effects of targeting higher versus lower arterial oxygen saturations on death or disability in extremely preterm infants
    • Schmidt B, Whyte RK, Asztaols EV, Moddemann D, Poets C, Rabi Y, et al., Effects of targeting higher versus lower arterial oxygen saturations on death or disability in extremely preterm infants. JAMA 2013; 309: 2111-20.
    • (2013) JAMA , vol.309 , pp. 2111-2120
    • Schmidt, B.1    Whyte, R.K.2    Asztaols, E.V.3    Moddemann, D.4    Poets, C.5    Rabi, Y.6
  • 11
    • 84878821409 scopus 로고    scopus 로고
    • European consensus guidelines on the management of neonatal respiratory distress syndrome in preterm infants - 2013 update
    • Sweet DG, Carnielli V, Greisen G, Hallman M, Ozek E, Plavka R, et al., European consensus guidelines on the management of neonatal respiratory distress syndrome in preterm infants-2013 update. Neonatology 2013; 103: 353-68.
    • (2013) Neonatology , vol.103 , pp. 353-368
    • Sweet, D.G.1    Carnielli, V.2    Greisen, G.3    Hallman, M.4    Ozek, E.5    Plavka, R.6
  • 12
    • 79951673225 scopus 로고    scopus 로고
    • Nurse: Patient ratio and achievement of oxygen saturation goals in premature infants
    • Sink DW, Hope SA, Hagadorn JI,. Nurse: patient ratio and achievement of oxygen saturation goals in premature infants. Arch Dis Child Fetal Neonatal Ed 2011; 96: F93-8.
    • (2011) Arch Dis Child Fetal Neonatal Ed , vol.96 , pp. F93-F98
    • Sink, D.W.1    Hope, S.A.2    Hagadorn, J.I.3
  • 14
    • 84869488846 scopus 로고    scopus 로고
    • Low oxygen saturation target range is associated with increased incidence of intermittent hypoxemia
    • Di FJ, Walsh M, Wrage L, Rich W, Finer N, Carlo WA, et al., Low oxygen saturation target range is associated with increased incidence of intermittent hypoxemia. J Pediatr 2012; 161: 1047-52.
    • (2012) J Pediatr , vol.161 , pp. 1047-1052
    • Di, F.J.1    Walsh, M.2    Wrage, L.3    Rich, W.4    Finer, N.5    Carlo, W.A.6
  • 15
    • 0027565974 scopus 로고
    • Episodes of spontaneous desaturations in infants with chronic lung disease at two different levels of oxygenation
    • McEvoy C, Durand M, Hewlett V,. Episodes of spontaneous desaturations in infants with chronic lung disease at two different levels of oxygenation. Pediatr Pulmonol 1993; 15: 140-4.
    • (1993) Pediatr Pulmonol , vol.15 , pp. 140-144
    • McEvoy, C.1    Durand, M.2    Hewlett, V.3
  • 16
    • 84940448245 scopus 로고    scopus 로고
    • Automated versus manual oxygen control with different saturation targets and modes of respiratory support in preterm infants
    • van Kaam A, Hummler H, Wilinska M, Swietlinski J, Lal M, te Pas A, et al., Automated versus manual oxygen control with different saturation targets and modes of respiratory support in preterm infants. J Pediatr 2015; 167: 545-550.e2.
    • (2015) J Pediatr , vol.167 , pp. 545-550e2
    • Van Kaam, A.1    Hummler, H.2    Wilinska, M.3    Swietlinski, J.4    Lal, M.5    Te Pas, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.