메뉴 건너뛰기




Volumn , Issue , 2003, Pages 239-244

Microneedles array for fluid extraction and drug delivery

Author keywords

[No Author keywords available]

Indexed keywords

CHEMICAL ANALYSIS; EXTRACTION; MEDICAL APPLICATIONS; MEMS; SOCIAL SCIENCES; SUBSTRATES;

EID: 84945136579     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MHS.2003.1249939     Document Type: Conference Paper
Times cited : (3)

References (13)
  • 2
    • 0141772857 scopus 로고    scopus 로고
    • Micro electro-mechanical system for the application in medicine
    • Tang Yanghua, Ye Xiongying, Zhou Zhaoying. Micro Electro-Mechanical System For the Application In Medicine, China Mechanical Engineering, 2001;12(2):226-231
    • (2001) China Mechanical Engineering , vol.12 , Issue.2 , pp. 226-231
    • Yanghua, T.1    Xiongying, Y.2    Zhaoying, Z.3
  • 4
    • 0029086556 scopus 로고
    • Intraoperative neurophysiologic monitoring: Some technical considerations
    • A. D. Legatt, "Intraoperative Neurophysiologic Monitoring: Some Technical Considerations", Amer. J. EEG Technol., vol. 35, pp. 167-200, 1995.
    • (1995) Amer. J. EEG Technol. , vol.35 , pp. 167-200
    • Legatt, A.D.1
  • 5
    • 0031699257 scopus 로고    scopus 로고
    • Micromachined needles for the transdermal delivery of drugs
    • Heidelberg, Germany, Jan
    • Henry S, MaAllister D. V, Allen M. G, et al. Micromachined Needles for the Transdermal Delivery of Drugs. IEEE Micro Electro Mechanical Systems, Heidelberg, Germany, Jan. 1998:494-498
    • (1998) IEEE Micro Electro Mechanical Systems , pp. 494-498
    • Henry, S.1    Ma Allister, D.V.2    Allen, M.G.3
  • 7
    • 0014457408 scopus 로고
    • Optimum electrolytic chloriding of silver Electrodes
    • L. A. Geddes, L. E. Baker, and A. G. Moore, "Optimum electrolytic chloriding of silver Electrodes", Med. Biol. Eng., vol. 7, pp. 49-56, 1968.
    • (1968) Med. Biol. Eng. , vol.7 , pp. 49-56
    • Geddes, L.A.1    Baker, L.E.2    Moore, A.G.3
  • 9
    • 0036123966 scopus 로고    scopus 로고
    • Novel, side opened out-of-plane microneedles for microfluidic transdermal interfacing
    • Las Vegas, NV, 01/20-24/02, IEEE, Piscataway
    • Griss P, Stemme G. Novel, Side Opened Out-of-Plane Microneedles for Microfluidic Transdermal Interfacing. Proceedings of 15th International Conference on Micro Electro Mechanical Systems, Las Vegas, NV, 01/20-24/02, IEEE, Piscataway, 2002:467-470
    • (2002) Proceedings of 15th International Conference on Micro Electro Mechanical Systems , pp. 467-470
    • Griss, P.1    Stemme, G.2
  • 12
    • 0013229597 scopus 로고    scopus 로고
    • Three-dimensional hollow microneedle and microtube arrays
    • Transducers' 99, Sendai, Japan 06/7-10/99, Institute of Electrical Engineers of Japan, Tokyo
    • McAllister D. V., Cros F, Davis S. P, et al. Three-Dimensional Hollow Microneedle and Microtube Arrays. Proceedings of the 10th International Conference on Solid-State Sensors and Actuators (Transducers' 99), Sendai, Japan 06/7-10/99, Institute of Electrical Engineers of Japan, Tokyo, 1999:1098-1101
    • (1999) Proceedings of the 10th International Conference on Solid-state Sensors and Actuators , pp. 1098-1101
    • McAllister, D.V.1    Cros, F.2    Davis, S.P.3
  • 13
    • 0034578084 scopus 로고    scopus 로고
    • Microfabricated microneedles for gene and drug delivery"
    • Devin V. McAllister 1, Mark G. Allen 2, and Mark R. Prausnitz. Microfabricated Microneedles for Gene and Drug Delivery" Annu. Rev. Biomed. Eng. 2000. 02:289-313
    • (2000) Annu. Rev. Biomed. Eng , vol.2 , pp. 289-313
    • McAllister, D.V.1    Allen, M.G.2    Prausnitz, M.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.