메뉴 건너뛰기




Volumn , Issue , 2003, Pages 175-180

An in vitro membranous arterial model based on individual information for intravascular neurosurgery

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL EQUIPMENT; COMPUTERIZED TOMOGRAPHY; MEDICAL IMAGING; NEUROSURGERY; SOCIAL SCIENCES; SURGERY;

EID: 84945118663     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/MHS.2003.1249929     Document Type: Conference Paper
Times cited : (2)

References (8)
  • 1
    • 0030684204 scopus 로고    scopus 로고
    • Micro force sensor for intravascular neurosurgery
    • M. Tanimoto, F. Arai, T. Fukuda et al., "Micro Force Sensor for Intravascular Neurosurgery", ICRA1997, ppl561-1566
    • ICRA1997 , pp. 1561-1566
    • Tanimoto, M.1    Arai, F.2    Fukuda, T.3
  • 2
    • 0031644170 scopus 로고    scopus 로고
    • Augmentation of safety in tele-operation system for intravascular neurosurgery
    • M. Tanimoto, F. Arai, T. Fukuda et al., "Augmentation of Safety in Tele-operation System for Intravascular Neurosurgery", ICRA 1998, pp2890-2895
    • (1998) ICRA , pp. 2890-2895
    • Tanimoto, M.1    Arai, F.2    Fukuda, T.3
  • 3
    • 84951769891 scopus 로고    scopus 로고
    • Rapid production of an in vitro anatomical model of human cerebral arteries based on CT images
    • S. Ikeda, F. Arai, T. Fukuda, et al., "Rapid Production of an in vitro Anatomical Model of Human Cerebral Arteries based on CT Images", MHS 2002, pp41-47
    • (2002) MHS , pp. 41-47
    • Ikeda, S.1    Arai, F.2    Fukuda, T.3
  • 4
    • 0034109102 scopus 로고    scopus 로고
    • Dense packing of cerebral aneurysms: An in vitro study with detachable platinum coils
    • M. Piotin, S. Mandai, K. J. Murphy et al., (2000) "Dense Packing of Cerebral Aneurysms: An In Vitro Study with Detachable Platinum Coils" AJNR Am J Neuroradiol, Vol. 21, pp. 757-760
    • (2000) AJNR Am J Neuroradiol , vol.21 , pp. 757-760
    • Piotin, M.1    Mandai, S.2    Murphy, K.J.3
  • 5
    • 0037225109 scopus 로고    scopus 로고
    • In vitro measurement of fluid-induced wall shear stress in unruptured cerebral aneuryms harboring blebs
    • S. Tateshima, Y. Murayarna, J. P. Villablanca et al., (2003) "In Vitro Measurement of Fluid-Induced Wall Shear Stress in Unruptured Cerebral Aneuryms Harboring Blebs" Stroke, vol. 34 pp. 193-199
    • (2003) Stroke , vol.34 , pp. 193-199
    • Tateshima, S.1    Murayarna, Y.2    Villablanca, J.P.3
  • 6
    • 0024848298 scopus 로고    scopus 로고
    • Transparent elastic arterial model 1: A brief technical note
    • Kerber CW, Heilman CB, Zanetti PH, (1998) "Transparent elastic arterial model 1: a brief technical note" Biorheology vol. 26, pp1041-1049
    • (1998) Biorheology , vol.26 , pp. 1041-1049
    • Kerber, C.W.1    Heilman, C.B.2    Zanetti, P.H.3
  • 7
    • 0030907567 scopus 로고    scopus 로고
    • Technical note, surg radiol anat
    • P. Gailloud, J. R. Pray, M. Muster et al., (1997) "Technical note, Surg Radiol Anat", Surg Radiol Anat, vol. 19, pp119-121
    • (1997) Surg Radiol Anat , vol.19 , pp. 119-121
    • Gailloud, P.1    Pray, J.R.2    Muster, M.3
  • 8
    • 0037295466 scopus 로고    scopus 로고
    • Artificial cerebral aneurysm model for medical testing, training, and research
    • K. Sugiu, J. B. Martin, B. Jean et al., (2003) "Artificial Cerebral Aneurysm Model for Medical Testing, Training, and Research" Neuroi Med Chir, vol 43, pp 69-73
    • (2003) Neuroi Med Chir , vol.43 , pp. 69-73
    • Sugiu, K.1    Martin, J.B.2    Jean, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.