메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 1201-1204

Flexible glucose sensor with a film-type oxygen electrode by microfabrication techniques

Author keywords

Biomembranes; Chemical industry; Chemical sensors; Chemical transducers; Electrodes; Oxygen; Resins; Sensor phenomena and characterization; Sensor systems; Sugar

Indexed keywords

ACTUATORS; CHEMICAL INDUSTRY; CHEMICAL SENSORS; ELECTRODES; ELECTROLYTES; FLEXIBLE STRUCTURES; GLUCOSE; GLUCOSE OXIDASE; GLUCOSE SENSORS; METAL DRAWING; METAL WORKING; MICROANALYSIS; MICROFABRICATION; MICROSYSTEMS; OXYGEN; PHOTOLITHOGRAPHY; RESINS; SILVER; SOLID-STATE SENSORS; SUGAR INDUSTRY; SUGARS; TRANSDUCERS; VOLTAGE REGULATORS;

EID: 84944737519     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2003.1216987     Document Type: Conference Paper
Times cited : (4)

References (12)
  • 1
    • 0026001464 scopus 로고
    • Determination of basal tear turnover in insulin-dependent diabetes mellitus patients by fluorophotometry
    • Th.R. Stolwijk, J.A. van Best, H.H.P.J. Lemkes, R.J.W. de Keizer, J.A. Oosterhuis, "Determination of basal tear turnover in insulin-dependent diabetes mellitus patients by fluorophotometry", Int. Opthalmol. 15, 377-381, (1991).
    • (1991) Int. Opthalmol , vol.15 , pp. 377-381
    • Stolwijk, Th.R.1    Van Best, J.A.2    Lemkes, H.H.P.J.3    De Keizer, R.J.W.4    Oosterhuis, J.A.5
  • 3
    • 0028345843 scopus 로고
    • Analysis of metabolites in sweat as a measure of physical condition
    • K. Mitsubayashi, M. Suzuki, E. Tamiya, I. Karube, "Analysis of metabolites in sweat as a measure of physical condition", Anal. Chim. Acta., 289, 27-34, (1994).
    • (1994) Anal. Chim. Acta. , vol.289 , pp. 27-34
    • Mitsubayashi, K.1    Suzuki, M.2    Tamiya, E.3    Karube, I.4
  • 5
    • 0023910374 scopus 로고
    • A non-invasive method of blood glucose evaluation by tear glucose measurement, for the detection and control of diabetic states
    • A. Romano and F. Rolant, "A non-invasive method of blood glucose evaluation by tear glucose measurement, for the detection and control of diabetic states," Metab. Pediat.Sys. Ophthamol. Vol.11, 78 (1988).
    • (1988) Metab. Pediat.Sys. Ophthamol , vol.11 , pp. 78
    • Romano, A.1    Rolant, F.2
  • 7
    • 0018967308 scopus 로고
    • Tear glucose levels in normal people and in diabetic patients
    • D.K. Sen, G.S. Sarin, "Tear glucose levels in normal people and in diabetic patients", Br. J. Ophthalmol. 64, 693-699, (1980).
    • (1980) Br. J. Ophthalmol. , vol.64 , pp. 693-699
    • Sen, D.K.1    Sarin, G.S.2
  • 9
    • 0017367259 scopus 로고
    • Collection method dependent concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycaemic conditions
    • N.J. Haeringen, E. Glasius, "Collection method dependent concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycaemic conditions", Albrecht v. Graefes Arch. Klin. Exp. Ophthal, 202, 1-11, (1977).
    • (1977) Albrecht V. Graefes Arch. Klin. Exp. Ophthal , vol.202 , pp. 1-11
    • Haeringen, N.J.1    Glasius, E.2
  • 11
    • 25544441078 scopus 로고    scopus 로고
    • Optical-transparent oxygen sensor with a thinner membrane structure
    • K. Mitsubayashi, Y. Hashimoto, "Optical-transparent oxygen sensor with a thinner membrane structure," Analytical Sciences, Vol.17 (Suppl.), i773-i776 (2001).
    • (2001) Analytical Sciences , vol.17 , pp. i773-i776
    • Mitsubayashi, K.1    Hashimoto, Y.2
  • 12
    • 0024986321 scopus 로고
    • Effect of anode materials on the characteristics of the miniature Clark-type oxygen electrode
    • H. Suzuki, A. Sugama, N. Kojima, "Effect of anode materials on the characteristics of the miniature Clark-type oxygen electrode", Anal. Chim. Acta, 233, 275-281, (1990).
    • (1990) Anal. Chim. Acta , vol.233 , pp. 275-281
    • Suzuki, H.1    Sugama, A.2    Kojima, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.