메뉴 건너뛰기




Volumn 2, Issue , 2003, Pages 959-962

Microfabricated electrode arrays for restoring lost sensory and motor functions

Author keywords

Brain stimulation; Cerebral cortex; Electrodes; Microelectrodes; Micromotors; Neural prosthesis; Neurons; Parkinson's disease; Prosthetics; Sensor arrays

Indexed keywords

ACTUATORS; BRAIN; DISEASES; ELECTRODES; MICROELECTRODES; MICROMOTORS; MICROSYSTEMS; NEURAL PROSTHESES; NEURONS; NEUROPHYSIOLOGY; PROSTHETICS; RESTORATION; SENSOR ARRAYS; TRANSDUCERS;

EID: 84944716030     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/SENSOR.2003.1216926     Document Type: Conference Paper
Times cited : (11)

References (15)
  • 1
    • 0033972960 scopus 로고    scopus 로고
    • Artificial vision for the blind by connecting a television camera to the visual cortex
    • Dobelle, W.H., Artificial vision for the blind by connecting a television camera to the visual cortex. Asaio J, 2000. 46(1): p.3-9.
    • (2000) Asaio J , vol.46 , Issue.1 , pp. 3-9
    • Dobelle, W.H.1
  • 2
    • 0030826554 scopus 로고    scopus 로고
    • Learning retina implants with epiretinal contacts
    • Eckmiller, R., Learning retina implants with epiretinal contacts. Ophthalmic Res, 1997. 29(5): p.281-9.
    • (1997) Ophthalmic Res , vol.29 , Issue.5 , pp. 281-289
    • Eckmiller, R.1
  • 4
    • 0032947055 scopus 로고    scopus 로고
    • A neural interface for a cortical vision prosthesis
    • Normann, R.A., et al., A neural interface for a cortical vision prosthesis. Vision Res, 1999. 39(15): p.2577-87.
    • (1999) Vision Res , vol.39 , Issue.15 , pp. 2577-2587
    • Normann, R.A.1
  • 5
    • 0029964253 scopus 로고    scopus 로고
    • Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex
    • Schmidt, E.M., et al., Feasibility of a visual prosthesis for the blind based on intracortical microstimulation of the visual cortex. Brain, 1996. 119: p.507-522.
    • (1996) Brain , vol.119 , pp. 507-522
    • Schmidt, E.M.1
  • 6
    • 0030151086 scopus 로고    scopus 로고
    • Ocular implants for the blind
    • Wyatt, J. and J. Rizzo, Ocular implants for the blind, in IEEE Spectrum. 1996. p.47-53.
    • (1996) IEEE Spectrum , pp. 47-53
    • Wyatt, J.1    Rizzo, J.2
  • 7
    • 0036039162 scopus 로고    scopus 로고
    • The subretinal implant: Can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision?
    • discussion 52-3
    • Zrenner, E., The subretinal implant: can microphotodiode arrays replace degenerated retinal photoreceptors to restore vision? Ophthalmologica, 2002. 216(Suppl 1): p.8-20; discussion 52-3.
    • (2002) Ophthalmologica , vol.216 , pp. 8-20
    • Zrenner, E.1
  • 8
    • 0035171034 scopus 로고    scopus 로고
    • Electrical stimulation of anterior visual pathways in retinitis pigmentosa
    • Delbeke, J., et al., Electrical stimulation of anterior visual pathways in retinitis pigmentosa. Invest Ophthalmol Vis Sci, 2001. 42(1): p.291-7.
    • (2001) Invest Ophthalmol Vis Sci , vol.42 , Issue.1 , pp. 291-297
    • Delbeke, J.1
  • 9
    • 0014253620 scopus 로고
    • The visual sensations produced by electrical stimulation of the medial occipital cortex
    • Brindley, G.S. and W.S. Lewin, The visual sensations produced by electrical stimulation of the medial occipital cortex. J Physiol (Lond), 1968. 194(2): p.54-5P.
    • (1968) J Physiol (Lond) , vol.194 , Issue.2 , pp. 54-55P
    • Brindley, G.S.1    Lewin, W.S.2
  • 10
    • 0028519255 scopus 로고
    • Artificial vision for the blind. The summit may be closer than you think
    • Dobelle, W.H., Artificial vision for the blind. The summit may be closer than you think.ASAIO J., 1994. 40(4): p.919-22.
    • (1994) ASAIO J. , vol.40 , Issue.4 , pp. 919-922
    • Dobelle, W.H.1
  • 11
    • 0028662508 scopus 로고
    • A three-dimensional microelectrode array for chronic neural recording
    • Hoogerwerf, A.C. and K.D. Wise, A three-dimensional microelectrode array for chronic neural recording. IEEE Trans. Biomed. Eng., 1994. 41(12): p.1136-46.
    • (1994) IEEE Trans. Biomed. Eng. , vol.41 , Issue.12 , pp. 1136-1146
    • Hoogerwerf, A.C.1    Wise, K.D.2
  • 12
    • 0026735250 scopus 로고
    • A glass/silicon composite intracortical electrode array
    • Jones, K.E., P.K. Campbell, and R.A. Normann, A glass/silicon composite intracortical electrode array. Ann. Biomed. Eng., 1992. 20(4): p.423-437.
    • (1992) Ann. Biomed. Eng. , vol.20 , Issue.4 , pp. 423-437
    • Jones, K.E.1    Campbell, P.K.2    Normann, R.A.3
  • 13
    • 0035905783 scopus 로고    scopus 로고
    • Actions from thoughts
    • Nicolelis, M.A., Actions from thoughts. Nature, 2001. 409(6818): p.403-7.
    • (2001) Nature , vol.409 , Issue.6818 , pp. 403-407
    • Nicolelis, M.A.1
  • 14
    • 0037075605 scopus 로고    scopus 로고
    • Instant neural control of a movement signal
    • Serruya, M.D., et al., Instant neural control of a movement signal. Nature, 2002. 416(6877): p.141-2.
    • (2002) Nature , vol.416 , Issue.6877 , pp. 141-142
    • Serruya, M.D.1
  • 15
    • 0037036102 scopus 로고    scopus 로고
    • Direct cortical control of 3D neuroprosthetic devices
    • Taylor, D.M., S.I. Tillery, and A.B. Schwartz, Direct cortical control of 3D neuroprosthetic devices. Science, 2002. 296(5574): p.1829-32.
    • (2002) Science , vol.296 , Issue.5574 , pp. 1829-1832
    • Taylor, D.M.1    Tillery, S.I.2    Schwartz, A.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.